Selective and sensitive determination of phenolic compounds using carbon screen printing electrodes modified with reduced graphene oxide and silver nanoparticles

被引:8
|
作者
Chakkarapani, Lakshmi Devi [1 ]
Bytesnikova, Zuzana [2 ]
Richtera, Lukas [2 ]
Brandl, Martin [1 ]
机构
[1] Univ Continuing Educ, Ctr Water & Environm Sensors, Krems, Austria
[2] Mendel Univ Brno, Dept Chem & Biochem, Zemedelska 1, Brno 61300, Czech Republic
关键词
Nanoparticles; Screen -printed electrodes; Butylated hydroxyanisole; Reduced graphene oxide; Vanillin; BUTYLATED HYDROXYANISOLE BHA; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL DETECTION; ANTIOXIDANT ACTIVITY; ASCORBIC-ACID; FOOD SAMPLES; VANILLIN; SENSOR; METAL; HYDROXYTOLUENE;
D O I
10.1016/j.apmt.2024.102113
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Butylated hydroxyanisole (BHA) and vanillin (VA) are the well-known phenolic compounds often used as preservatives in various foods and beverages. BHA is a safe additive whose concentration in food should not exceed 0.02 %. VA is used as a flavoring agent in foods, but the maximum allowable amount for VA is limited to 7 mg/ 100 g. However, elevated levels of BHA and VA can lead to severe health issues in the human body. To ensure reliable quality control, the food industry must accurately determine the BHA and VA content in food. In this work, we developed an electrochemical sensor for the detection of BHA and VA using a screen-printed electrode (SPE) modified with reduced graphene oxide and silver nanoparticles (RGO-Ag NPs). The SPE modified with RGO-Ag NPs showed an oxidation potential for BHA of 0.34 V and 0.62 V for VA in phosphate buffer solution (0.1 M PBS, pH 7.4) at a scan rate of 50 mV/s. In contrast, the unmodified SPE shows no significant current and oxidation potential response of BHA and VA under the same experimental conditions. (Cyclic voltammetry (CV) measurements for BHA ranged from 9.9 mu M to 239.25 mu M, while differential pulse voltammetry (DPV) measurements of BHA provided a linear calibration from 0.49 mu M to 3.67 mu M with a lower detection limit of 0.16 mu M (S/N = 3). For VA, CV measurements covered a range from 82.6 mu M to 242.4 mu M, and DPV measurements displayed a linear calibration from 1.47 mu M to 12.79 mu M with a detection limit of 0.15 mu M (S/N = 3).
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Reduced Graphene Oxide/Gold Nanoparticles Modified Screen-Printed Electrode for the Determination of Palmitic Acid
    Ching, Chin Boon
    Abdullah, Jaafar
    Yusof, Nor Azah
    JOURNAL OF SENSORS, 2021, 2021
  • [22] Highly Sensitive Determination of Folic Acid Using Graphene Oxide Nanoribbon Film Modified Screen Printed Carbon Electrode
    Mani, Veerappan
    Umamaheswari, Rajaji
    Chen, Shen-Ming
    Govindasamy, Mani
    Su, Chaochin
    Sathiyan, Anandaraj
    Merlin, Johnson Princy
    Keerthi, Murugan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (01): : 475 - 484
  • [23] Selective and sensitive determination of dopamine by composites of polypyrrole and graphene modified electrodes
    Si, Peng
    Chen, Hailan
    Kannan, Palanisamy
    Kim, Dong-Hwan
    ANALYST, 2011, 136 (24) : 5134 - 5138
  • [24] Inkjet printing of silver electrodes on top of reduced graphene oxide layers for sensor applications
    Chatla, S.
    Al-Hamry, A.
    Mueller, C.
    Kanoun, O.
    Weise, D.
    Sowade, E.
    Baumann, R. R.
    2016 NANOTECHNOLOGY FOR INSTRUMENTATION AND MEASUREMENT (NANOFIM), 2016,
  • [25] Cyclic voltammetric determination of capsaicin by using electrochemically deposited tin and reduced graphene oxide on screen-printed carbon electrodes
    Numphud, Wasukamol
    Chienthavorn, Orapin
    Siriwatcharapiboon, Wilai
    SCIENCEASIA, 2020, 46 (05): : 586 - +
  • [26] Reduced Graphene Oxide-Modified Screen-Printed Carbon (rGO-SPCE)-Based Disposable Electrochemical Sensor for Sensitive and Selective Determination of Ethyl Carbamate
    Zhao, Xiaoyu
    Zuo, Juanjuan
    Qiu, Shue
    Hu, Wenshuai
    Wang, Yanfei
    Zhang, Juankun
    FOOD ANALYTICAL METHODS, 2017, 10 (10) : 3329 - 3337
  • [27] Reduced Graphene Oxide-Modified Screen-Printed Carbon (rGO-SPCE)-Based Disposable Electrochemical Sensor for Sensitive and Selective Determination of Ethyl Carbamate
    Xiaoyu Zhao
    Juanjuan Zuo
    Shue Qiu
    Wenshuai Hu
    Yanfei Wang
    Juankun Zhang
    Food Analytical Methods, 2017, 10 : 3329 - 3337
  • [28] Modified Glassy Carbon Electrode with Silver Nanoparticles/Polyaniline/Reduced Graphene Oxide Nanocomposite for the Simultaneous Determination of Biocompounds in Biological Fluids
    Ghanbari, Kh
    Moloudi, M.
    Bonyadi, S.
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2019, 10 (04) : 361 - 372
  • [29] Highly sensitive and selective determination of methylergometrine maleate using carbon nanofibers/silver nanoparticles composite modified carbon paste electrode
    Kalambate, Pramod K.
    Rawool, Chaitali R.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 69 : 453 - 461
  • [30] Reduced graphene oxide modified with silver nanoparticles for the electrochemical detection of estriol
    Donini, Caruane Alves
    Leme da Silva, Martin Kassio
    Simoes, Rafael Plana
    Cesarino, Ivana
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 809 : 67 - 73