Comparison of a High-Pitch Non-ECG-Gated and a Prospective ECG-Gated Protocol for Preprocedural Computed Tomography Imaging Before TAVI/TAVR

被引:2
|
作者
Shnayien, Seyd [1 ]
Beetz, Nick Lasse [1 ,2 ]
Bressem, Keno Kyrill [1 ]
Hamm, Bernd [1 ]
Niehues, Stefan Markus [1 ]
机构
[1] Charite, Dept Radiol, Berlin, Germany
[2] Charite Univ Med Berlin, Berlin Inst Hlth, Berlin, Germany
关键词
aortic valve; cardiac; CT-angiography; AORTIC-VALVE-REPLACEMENT; CORONARY CT ANGIOGRAPHY; EXPERT CONSENSUS DOCUMENT; IMPLANTATION; QUALITY; TAVR;
D O I
10.1055/a-1898-6504
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Preprocedural computed tomography (CT) imaging before transcatheter aortic valve implantation/replacement (TAVI/TAVR) requires high diagnostic accuracy without motion artifacts. The aim of this retrospective study is to compare the image quality of a high-pitch non-electrocardiography (ECG)-gated CT protocol used in patients with atrial tachyarrhythmias with a prospectively ECG-gated CT protocol used in patients with sinus rhythm. Materials and Methods We retrospectively included 108 patients who underwent preprocedural CT imaging before TAVI/TAVR. 52 patients with sinus rhythm were imaged using a prospectively ECG-gated protocol (Group A), and 56 patients with atrial tachyarrhythmias were imaged using the high-pitch non-ECG-gated protocol (Group B). Image quality was rated subjectively by two experienced radiologists and assessed by objective parameters including radiation dose, image noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) at the levels of the aortic root and abdominal aorta. Results Subjective image quality was equally good with both CT protocols, and interrater agreement was substantial in both groups but tended to be higher in Group B at the level of the aortic root (Group A: kw = 0.644, Group B: kw = 0.741). With the high-pitch non-ECG-gated CT protocol, image noise was significantly increased (p = 0.001), whereas the SNR, CNR, and radiation dose were significantly decreased (p = 0.002, p = 0.003, and p < 0.001, respectively) at the level of the aortic root compared to the prospectively ECG-gated CT protocol. Conclusion The high-pitch non-ECG-gated protocol yields images with similar subjective image quality compared with the prospectively ECG-gated CT protocol and allows motionfree assessment of the aortic root for accurate TAVI/TAVR planning. The high-pitch non-ECG-gated protocol may be used as an alternative for preprocedural CT imaging in patients with atrial tachyarrhythmias.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 50 条
  • [41] Noninvasive evaluation of global left ventricular myocardial function with ECG-gated 16-slice multidetector computed tomography in comparison with magnetic resonance imaging
    Burgstahler, C
    Heuschmid, M
    Rothfuss, JK
    Kuettner, A
    Beck, T
    Kopp, AF
    Claussen, CD
    Schroeder, S
    CIRCULATION, 2004, 110 (17) : 573 - 574
  • [42] Low dose prospective ECG-gated delayed enhanced dual-source computed tomography in reperfused acute myocardial infarction comparison with cardiac magnetic resonance
    Wang, Rui
    Zhang, Zhaoqi
    Xu, Lei
    Ma, Qin
    He, Yi
    Lu, Dongxu
    Yu, Wei
    Fan, Zhanming
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 326 - 330
  • [43] Feasibility of a Single Contrast Bolus High-Pitch Pulmonary CT Angiography Protocol Followed by Low-Dose Retrospectively ECG-Gated Cardiac CT in Patients with Suspected Pulmonary Embolism
    Schaefer, Julia Carmen
    Haubenreisser, Holger
    Meyer, Mathias
    Gruettner, Joachim
    Walter, Thomas
    Borggrefe, Martin
    Schoepf, Joseph U.
    Nance, John W., Jr.
    Schoenberg, Stefan O.
    Henzler, Thomas
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2018, 190 (06): : 542 - 550
  • [44] DETERMINATION OF LEFT-VENTRICULAR VOLUMES AND EJECTION FRACTION BY ECG-GATED COMPUTED-TOMOGRAPHY - COMPARISON OF METHODS IN RELATION TO BIPLANE ANGIOGRAPHY
    MUHLBERGER, V
    KNAPP, E
    NEDDEN, DZ
    BRAUNSTEINER, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1984, 73 (03): : 142 - 150
  • [45] Multidetector Computed Tomography for Coronary Stents Imaging: High-Voltage (140-kVp) Prospective ECG-Triggered Versus Standard-Voltage (120-kVp) Retrospective ECG-Gated Helical Scanning
    Esposito, Antonio
    Colantoni, Caterina
    De Cobelli, Francesco
    Del Vecchio, Antonella
    Palmisano, Anna
    Calandrino, Riccardo
    Del Maschio, Alessandro
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 395 - 401
  • [46] Study of myocardial contrast enhancement patterns using ECG-gated multislice computed tomography in myocarditis: comparison with non-ST-elevation acute myocardial infarction
    Dambrin, G
    Wartski, M
    Toussaint, M
    Laissy, JP
    Caussin, C
    Lancelin, B
    Angel, C
    Paul, JF
    EUROPEAN HEART JOURNAL, 2004, 25 : 655 - 655
  • [47] Non-gated high-pitch computed tomography aortic angiography: Myocardial perfusion defects in patients with suspected aortic dissection
    Huang, Li-Ting
    Chan, Shih-Hung
    Chuang, Chia-Chang
    Tsai, Yi-Shan
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2017, 11 (03) : 208 - 212
  • [48] Prospectively ECG-gated multidetector computed tomography viability imaging accurately quantifies infarct size while lowering the radiation dose by an order of magnitude
    George, Richard T.
    Schuleri, Karl H.
    Bluemke, David A.
    Hare, Joshua M.
    Lima, Joao A.
    Lardo, Albert C.
    CIRCULATION, 2006, 114 (18) : 818 - 818
  • [49] High-pitch prospective ECG-triggered helical coronary computed tomography angiography in clinical practice: image quality and radiation dose
    Kjell Bogaard
    Friso M. van der Zant
    Remco J. J. Knol
    Sjoerd Reinders
    Marije M. G. Krul
    Albert C. van Rossum
    Paul Knaapen
    Jan H. Cornel
    The International Journal of Cardiovascular Imaging, 2015, 31 : 125 - 133
  • [50] High-pitch prospective ECG-triggered helical coronary computed tomography angiography in clinical practice: image quality and radiation dose
    Bogaard, Kjell
    van der Zant, Friso M.
    Knol, Remco J. J.
    Reinders, Sjoerd
    Krul, Marije M. G.
    van Rossum, Albert C.
    Knaapen, Paul
    Cornel, Jan H.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (01): : 125 - 133