Multidetector Computed Tomography for Coronary Stents Imaging: High-Voltage (140-kVp) Prospective ECG-Triggered Versus Standard-Voltage (120-kVp) Retrospective ECG-Gated Helical Scanning

被引:6
|
作者
Esposito, Antonio [1 ,2 ,3 ,4 ]
Colantoni, Caterina [1 ,2 ,3 ,4 ]
De Cobelli, Francesco [1 ,2 ,3 ,4 ]
Del Vecchio, Antonella [4 ]
Palmisano, Anna [1 ,2 ,3 ,4 ]
Calandrino, Riccardo [4 ]
Del Maschio, Alessandro [1 ,2 ,3 ,4 ]
机构
[1] Ist Sci San Raffaele, Dept Radiol, I-20132 Milan, Italy
[2] Ist Sci San Raffaele, Expt Imaging Ctr, I-20132 Milan, Italy
[3] Univ Vita Salute San Raffaele, I-20132 Milan, Italy
[4] Ist Sci San Raffaele, Med Phys Serv, I-20132 Milan, Italy
关键词
cardiac imaging; multidetector computed tomography; coronary arteries; coronary computed tomography angiography; stents; HEART-ASSOCIATION COMMITTEE; IN-VITRO EVALUATION; CARDIOVASCULAR RADIOLOGY; SCIENTIFIC STATEMENT; ARTERY STENTS; ANGIOGRAPHY; CT; VISUALIZATION; INTERVENTION; MULTICENTER;
D O I
10.1097/RCT.0b013e3182873559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare prospective electrocardiogram (ECG)-triggered high-voltage coronary computed tomography (CT) angiography (CTA; 140-kVp P-cCTA) with retrospective ECG-gated standard-voltage cCTA (120-kVp R-cCTA), in patients with coronary stents. Methods: Fifty-two patients with coronary stents were studied with 64-slice multidetector scanner. Ninety-three stents were analyzed: 55 with 140-kVp P-cCTA and 38 with 120-kVp R-cCTA. Image quality (IQ), diagnostic confidence (DC), in-stent assessable lumen, artificial narrowing, and effective radiation dose were compared between techniques. Results: Image quality and DC were significantly better for the 140-kVp P-cCTA in comparison with the 120-kVp R-cCTA (IQ, 1.1 +/- 0.36 vs 1.7 +/- 0.60, respectively; P < 0.00001. Diagnostic confidence: 1.1 +/- 0.29 vs 1.5 +/- 0.65 respectively; P < 0.0001). In-stent assessable lumen and artificial narrowing were comparable between the techniques. Effective dose was lower for the 140-kVp P-cCTA (6.7 +/- 2.07 mSv vs 15.8 +/- 6.89 mSv; P < 0.0001). Conclusions: High voltage combined with axial prospective ECG-triggered scan improved IQ and DC in stent cCTA imaging but failed to improve the diameter of in-stent assessable lumen and to reduce the artificial narrowing compared with the 120-kVp R-cCTA. Effective dose was 60% lower for the 140-kVp P-cCTA.
引用
收藏
页码:395 / 401
页数:7
相关论文
共 4 条
  • [1] High-definition computed tomography for coronary artery stents: image quality and radiation doses for low voltage (100 kVp) and standard voltage (120 kVp) ECG-triggered scanning
    Ji Won Lee
    Chang Won Kim
    Han Cheol Lee
    Ming-Ting Wu
    Lee Hwangbo
    Ki Seok Choo
    June Hong Kim
    Ki-Nam Lee
    Jin You Kim
    Yeon Joo Jeong
    The International Journal of Cardiovascular Imaging, 2015, 31 : 39 - 49
  • [2] High-definition computed tomography for coronary artery stents: image quality and radiation doses for low voltage (100 kVp) and standard voltage (120 kVp) ECG-triggered scanning
    Lee, Ji Won
    Kim, Chang Won
    Lee, Han Cheol
    Wu, Ming-Ting
    Hwangbo, Lee
    Choo, Ki Seok
    Kim, June Hong
    Lee, Ki-Nam
    Kim, Jin You
    Jeong, Yeon Joo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 : 39 - 49
  • [3] Prospective ECG-triggered axial CT at 140-kV tube voltage improves coronary in-stent restenosis visibility at a lower radiation dose compared with conventional retrospective ECG-gated helical CT
    Horiguchi, Jun
    Fujioka, Chikako
    Kiguchi, Masao
    Yamamoto, Hideya
    Kitagawa, Toshiro
    Kohno, Shingo
    Ito, Katsuhide
    EUROPEAN RADIOLOGY, 2009, 19 (10) : 2363 - 2372
  • [4] Prospective ECG-triggered axial CT at 140-kV tube voltage improves coronary in-stent restenosis visibility at a lower radiation dose compared with conventional retrospective ECG-gated helical CT
    Jun Horiguchi
    Chikako Fujioka
    Masao Kiguchi
    Hideya Yamamoto
    Toshiro Kitagawa
    Shingo Kohno
    Katsuhide Ito
    European Radiology, 2009, 19 : 2363 - 2372