Comparison of a High-Pitch Non-ECG-Gated and a Prospective ECG-Gated Protocol for Preprocedural Computed Tomography Imaging Before TAVI/TAVR

被引:2
|
作者
Shnayien, Seyd [1 ]
Beetz, Nick Lasse [1 ,2 ]
Bressem, Keno Kyrill [1 ]
Hamm, Bernd [1 ]
Niehues, Stefan Markus [1 ]
机构
[1] Charite, Dept Radiol, Berlin, Germany
[2] Charite Univ Med Berlin, Berlin Inst Hlth, Berlin, Germany
关键词
aortic valve; cardiac; CT-angiography; AORTIC-VALVE-REPLACEMENT; CORONARY CT ANGIOGRAPHY; EXPERT CONSENSUS DOCUMENT; IMPLANTATION; QUALITY; TAVR;
D O I
10.1055/a-1898-6504
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Preprocedural computed tomography (CT) imaging before transcatheter aortic valve implantation/replacement (TAVI/TAVR) requires high diagnostic accuracy without motion artifacts. The aim of this retrospective study is to compare the image quality of a high-pitch non-electrocardiography (ECG)-gated CT protocol used in patients with atrial tachyarrhythmias with a prospectively ECG-gated CT protocol used in patients with sinus rhythm. Materials and Methods We retrospectively included 108 patients who underwent preprocedural CT imaging before TAVI/TAVR. 52 patients with sinus rhythm were imaged using a prospectively ECG-gated protocol (Group A), and 56 patients with atrial tachyarrhythmias were imaged using the high-pitch non-ECG-gated protocol (Group B). Image quality was rated subjectively by two experienced radiologists and assessed by objective parameters including radiation dose, image noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) at the levels of the aortic root and abdominal aorta. Results Subjective image quality was equally good with both CT protocols, and interrater agreement was substantial in both groups but tended to be higher in Group B at the level of the aortic root (Group A: kw = 0.644, Group B: kw = 0.741). With the high-pitch non-ECG-gated CT protocol, image noise was significantly increased (p = 0.001), whereas the SNR, CNR, and radiation dose were significantly decreased (p = 0.002, p = 0.003, and p < 0.001, respectively) at the level of the aortic root compared to the prospectively ECG-gated CT protocol. Conclusion The high-pitch non-ECG-gated protocol yields images with similar subjective image quality compared with the prospectively ECG-gated CT protocol and allows motionfree assessment of the aortic root for accurate TAVI/TAVR planning. The high-pitch non-ECG-gated protocol may be used as an alternative for preprocedural CT imaging in patients with atrial tachyarrhythmias.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 50 条
  • [31] What non-coronary incidental findings can a radiologist detect in an ECG-gated computed tomography scan?
    Stochmal, Ewa
    Czekajska-Chechab, Elzbieta
    Wypchlo, Lukasz
    Jaskolski, Jakub
    MEDICAL STUDIES-STUDIA MEDYCZNE, 2022, 38 (04) : 263 - 272
  • [32] Coronary artery imaging by multislice, spiral computed tomography: A novel ECG-gated reconstruction technique for the improved image quality
    Furuhashi, S
    Sato, Y
    Inoue, F
    Imazeki, T
    Takahashi, M
    Kanmatsuse, K
    RADIOLOGY, 2002, 225 : 483 - 483
  • [33] Noninvasive coronary artery imaging by multislice spiral computed tomography - A novel approach for a retrospectively ECG-gated reconstruction technique
    Sato, Y
    Kanmatsuse, K
    Inoue, F
    Horie, T
    Kato, M
    Kusama, J
    Yoshimura, A
    Imazeki, T
    Furuhashi, S
    Takahashi, M
    CIRCULATION JOURNAL, 2003, 67 (02) : 107 - 111
  • [34] Quantification of peri-aortic root fat from non-contrast ECG-gated cardiac computed tomography
    Yun, Chun-Ho
    Longenecker, Chris T.
    Chang, Hui-Ru
    Mok, Greta S. P.
    Sun, Jing-Yi
    Liu, Chuan-Chuan
    Kuo, Jen-Yuan
    Hung, Chung-Lieh
    Wu, Tung-Hsin
    Yeh, Hung-I
    Yang, Fei-Shih
    Lee, Jason Jeun-Shenn
    Hou, Charles Jia-Yin
    Cury, Ricardo C.
    Bezerra, Hiram G.
    DATA IN BRIEF, 2015, 5 : 995 - 998
  • [35] Evaluation of global left ventricular myocardial function with ECG-gated multidetector spiral computed tomography: Comparison to the reference method magnetic resonance imaging
    Grude, M
    Juergens, KU
    Opitz, C
    Mueller, J
    Fischbach, R
    Heindel, W
    Wichter, T
    CIRCULATION, 2002, 106 (19) : 441 - 442
  • [36] Application of Prospective ECG-Gated High-Pitch 128-Slice Dual-Source CT Angiography in the Diagnosis of Congenital Extracardiac Vascular Anomalies in Infants and Children
    Nie, Pei
    Yang, Guangjie
    Wang, Ximing
    Duan, Yanhua
    Xu, Wenjian
    Li, Haiou
    Cao, Ting
    Liu, Xuejun
    Ji, Xiaopeng
    Cheng, Zhaoping
    Wang, Anbiao
    PLOS ONE, 2014, 9 (12):
  • [37] Prospective ECG-gated high-pitch dual-source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities: Radiation dose and diagnostic efficacy in a pediatric population
    Koplay, M.
    Kizilca, O.
    Cimen, D.
    Sivri, M.
    Erdogan, H.
    Guvenc, O.
    Oc, M.
    Oran, B.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (11) : 1141 - 1150
  • [38] The Effectiveness of Non-ECG-Gated Contrast-Enhanced Computed Tomography for the Diagnosis of Non-ST Segment Elevation Acute Coronary Syndrome
    Watanabe, Tomomi
    Furuse, Yoshiyuki
    Ohta, Yasutoshi
    Kato, Masahiko
    Ogawa, Toshihide
    Yamamoto, Kazuhiro
    INTERNATIONAL HEART JOURNAL, 2016, 57 (05) : 558 - 564
  • [39] Left Ventricular Pseudo-False Aneurysm Detected With ECG-Gated Multidetector Computed Tomography and Cardiac Magnetic Resonance Imaging
    Ohtani, Hayato
    Katoh, Hideki
    Saitoh, Takeji
    Shiraki, Katsunori
    Saotome, Masao
    Urushida, Tsuyoshi
    Satoh, Hiroshi
    Washiyama, Naoki
    Terada, Hitoshi
    Yamashita, Katsuji
    Hayashi, Hideharu
    CIRCULATION JOURNAL, 2010, 74 (09) : 1986 - 1988
  • [40] Feasibility of combined ECG-Gated and Helical acquisition mode in a pre-TAVI computed tomography angiography protocol using a fixed low-volume contrast medium injection
    Gallo, Giuseppe S.
    Gerasia, Roberta
    Caruso, Calogero
    Tafaro, Corrado
    Iannazzo, Erica
    Cannataci, Christine
    Gentile, Giovanni
    Mamone, Giuseppe
    Gandolfo, Caterina
    Miraglia, Roberto
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131