Iterative Denoising Accelerated 3D FLAIR Sequence for Hydrops MR Imaging at 3T

被引:1
|
作者
Quint, R. [1 ]
Vaussy, A. [3 ]
Stemmer, A. [4 ]
Hautefort, C. [2 ]
Houdart, E. [1 ,5 ]
Eliezer, M. [1 ,6 ]
机构
[1] Lariboisiere Univ Hosp, Dept Neuroradiol, Paris, France
[2] Lariboisiere Univ Hosp, Head & Neck Surg, Paris, France
[3] Siemens Healthineers France, St Denis, France
[4] Siemens Healthineers, Erlangen, Germany
[5] Univ Paris, Fac Med, Paris, France
[6] Lariboisiere Univ Hosp, Dept Neuroradiol, F-75010 Paris, France
关键词
ENDOLYMPHATIC HYDROPS; MENIERE;
D O I
10.3174/ajnr.A7953
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: 3D FLAIR sequences have become the criterion standard for identifying endolymphatic hydrops, but scan time remains an important limitation to their widespread use. Our purpose was to evaluate the diagnostic performance and image quality of an accelerated 3D FLAIR sequence combined with an iterative denoising algorithm. MATERIALS AND METHODS: This was a retrospective study performed on 30 patients with clinical suspicion of endolymphatic hydrops who underwent 3T MR imaging 4 hours after gadolinium injection using two 3D FLAIR sequences. The first (conventional FLAIR) was accelerated with a conventional turbo factor of 187. The second was accelerated with an increased turbo factor of 263, resulting in a 33% scan time reduction (5 minutes 36 seconds versus 8 minutes 15 seconds, respectively). A sequence was reconstructed in-line immediately after the accelerated 3D FLAIR acquisition from the same raw data with iterative denoising (accelerated-FLAIR iterative denoising). The signal intensity ratio image quality score and endolymphatic hydrops diagnosis were evaluated. RESULTS: The mean signal intensity ratio for symptomatic and asymptomatic ears of accelerated-FLAIR iterative denoising was significantly higher than the mean SNR of conventional FLAIR (29.5 versus 19 and 25.9 versus 16.3, P,.001). Compared with the conventional FLAIR sequence, the image-quality score was higher with accelerated-FLAIR iterative denoising (mean image-quality score, 3.8 [SD, 0.4] versus 3.3 [SD, 0.6] for accelerated-FLAIR iterative denoising and conventional FLAIR, respectively, P = .003). There was no significant difference in the diagnosis of endolymphatic hydrops between the 2 sequences. Interreader agreement was good-toexcellent. CONCLUSIONS: The iterative denoising algorithm applied to an accelerated 3D FLAIR sequence for exploration of endolymphatic hydrops enabled significantly reducing the scan time without compromising image quality and diagnostic performance.
引用
收藏
页码:1064 / 1069
页数:6
相关论文
共 50 条
  • [21] "Value of 3D STIR Gated MRI Sequence in Cardiac and Chest Imaging with 3T MRI": Initial Experiences
    Kandasamy, Geetha
    Peter, S. Babu
    Priya, R. Bharathi
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (01) : TC6 - TC9
  • [22] 3T MR imaging: The pros and cons - Reply
    Bradley, WG
    Safar, FG
    Hurtado, C
    Ord, J
    Alksne, JF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (09) : 1455 - 1455
  • [23] In vivo sodium MR imaging of the abdomen at 3T
    Judy R. James
    Anshuman Panda
    Chen Lin
    Ulrike Dydak
    Brian M. Dale
    Navin Bansal
    Abdominal Imaging, 2015, 40 : 2272 - 2280
  • [24] MR safety and imaging of Neuroform stents at 3T
    Nehra, A
    Moran, CJ
    Cross, DT
    Derdeyn, CP
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (09) : 1476 - 1478
  • [25] 3D MR thermometry of frozen tissue: Feasibility and accuracy during cryoablation at 3T
    Overduin, Christiaan G.
    Futterer, Jurgen J.
    Scheenen, Tom W. J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (06) : 1572 - 1579
  • [26] Improving Detection of Multiple Sclerosis Lesions in the Posterior Fossa Using an Optimized 3D-FLAIR Sequence at 3T
    Lecler, A.
    El Sanharawi, I.
    El Methni, J.
    Gout, O.
    Koskas, P.
    Savatovsky, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (07) : 1170 - 1176
  • [27] Identification of Endolymphatic Hydrops in Meniere's Disease Utilizing Delayed Postcontrast 3D FLAIR and Fused 3D FLAIR and CISS Color Maps
    Hagiwara, Mari
    Roland, J. Thomas, Jr.
    Wu, Xin
    Nusbaum, Annette
    Babb, James S.
    Roehm, Pamela C.
    Hammerschlag, Paul
    Lalwani, Anil K.
    Fatterpekar, Girish
    OTOLOGY & NEUROTOLOGY, 2014, 35 (10) : E337 - E342
  • [28] Generalized Multiple-Layer Appearance of the Cerebral Cortex with 3D FLAIR 7.0-T MR Imaging
    Zwanenburg, Jaco J. M.
    Hendrikse, Jeroen
    Luijten, Peter R.
    RADIOLOGY, 2012, 262 (03) : 995 - 1001
  • [29] 3D Turbo Spin-Echo Sequence with Motion-Sensitized Driven-Equilibrium Preparation for Detection of Brain Metastases on 3T MR Imaging
    Nagao, E.
    Yoshiura, T.
    Hiwatashi, A.
    Obara, M.
    Yamashita, K.
    Kamano, H.
    Takayama, Y.
    Kobayashi, K.
    Honda, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (04) : 664 - 670
  • [30] Assessment of central vein sign conspicuity in multicenter 3t flair☆ imaging
    Martin, M.
    Cao, Q.
    Renner, B.
    Daboul, L.
    O'Donnell, C.
    Moreno-Dominguez, D.
    Rodrigues, P.
    Derbyshire, J.
    Azevedo, C.
    Bar-Or, A.
    Caverzasi, E.
    Calabresi, P.
    Cree, B.
    Freeman, L.
    Henry, R.
    Longbrake, E.
    Oh, J.
    Papinutto, N.
    Samudralwar, R.
    Schindler, M.
    Sotirchos, E.
    Sicotte, N.
    Solomon, A.
    Shinohara, R.
    Reich, D.
    Ontaneda, D.
    Sati, P.
    MULTIPLE SCLEROSIS JOURNAL, 2020, 26 (3_SUPPL) : 376 - 377