Iterative Denoising Accelerated 3D FLAIR Sequence for Hydrops MR Imaging at 3T

被引:1
|
作者
Quint, R. [1 ]
Vaussy, A. [3 ]
Stemmer, A. [4 ]
Hautefort, C. [2 ]
Houdart, E. [1 ,5 ]
Eliezer, M. [1 ,6 ]
机构
[1] Lariboisiere Univ Hosp, Dept Neuroradiol, Paris, France
[2] Lariboisiere Univ Hosp, Head & Neck Surg, Paris, France
[3] Siemens Healthineers France, St Denis, France
[4] Siemens Healthineers, Erlangen, Germany
[5] Univ Paris, Fac Med, Paris, France
[6] Lariboisiere Univ Hosp, Dept Neuroradiol, F-75010 Paris, France
关键词
ENDOLYMPHATIC HYDROPS; MENIERE;
D O I
10.3174/ajnr.A7953
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: 3D FLAIR sequences have become the criterion standard for identifying endolymphatic hydrops, but scan time remains an important limitation to their widespread use. Our purpose was to evaluate the diagnostic performance and image quality of an accelerated 3D FLAIR sequence combined with an iterative denoising algorithm. MATERIALS AND METHODS: This was a retrospective study performed on 30 patients with clinical suspicion of endolymphatic hydrops who underwent 3T MR imaging 4 hours after gadolinium injection using two 3D FLAIR sequences. The first (conventional FLAIR) was accelerated with a conventional turbo factor of 187. The second was accelerated with an increased turbo factor of 263, resulting in a 33% scan time reduction (5 minutes 36 seconds versus 8 minutes 15 seconds, respectively). A sequence was reconstructed in-line immediately after the accelerated 3D FLAIR acquisition from the same raw data with iterative denoising (accelerated-FLAIR iterative denoising). The signal intensity ratio image quality score and endolymphatic hydrops diagnosis were evaluated. RESULTS: The mean signal intensity ratio for symptomatic and asymptomatic ears of accelerated-FLAIR iterative denoising was significantly higher than the mean SNR of conventional FLAIR (29.5 versus 19 and 25.9 versus 16.3, P,.001). Compared with the conventional FLAIR sequence, the image-quality score was higher with accelerated-FLAIR iterative denoising (mean image-quality score, 3.8 [SD, 0.4] versus 3.3 [SD, 0.6] for accelerated-FLAIR iterative denoising and conventional FLAIR, respectively, P = .003). There was no significant difference in the diagnosis of endolymphatic hydrops between the 2 sequences. Interreader agreement was good-toexcellent. CONCLUSIONS: The iterative denoising algorithm applied to an accelerated 3D FLAIR sequence for exploration of endolymphatic hydrops enabled significantly reducing the scan time without compromising image quality and diagnostic performance.
引用
收藏
页码:1064 / 1069
页数:6
相关论文
共 50 条
  • [31] Reliability of Central Vein Sign Imaging With 3T FLAIR* in a Multicenter Study
    Martin, Melissa Lynne
    Cao, Quy
    Luskin, Elaina
    Renner, Brian
    Daboul, Lynn
    O'Donnell, Carly M.
    Rodrigues, Paulo
    Derbyshire, John
    Azevedo, Christina J.
    Bar-Or, Amit
    Caverzasi, Eduardo
    Calabresi, Peter
    Cree, Bruce A. C.
    Freeman, Leorah
    Henry, Roland G.
    Longbrake, Erin E.
    Oh, Jiwon
    Papinutto, Nico
    Pelletier, Daniel
    Prchkovska, Vesna
    Ramos, Marc
    Samudralwar, Rohini D.
    Schindler, Matthew K.
    Sotirchos, Elias S.
    Sicotte, Nancy L.
    Solomon, Andrew J.
    Reich, Daniel S.
    Ontaneda, Daniel
    Shinohara, Russell T.
    Sati, Pascal
    JOURNAL OF NEUROIMAGING, 2025, 35 (01)
  • [32] Trabecular bone imaging using a 3D adiabatic inversion recovery prepared ultrashort TE Cones sequence at 3T
    Ma, Ya-Jun
    Chen, Yanjun
    Li, Liang
    Cai, Zhenyu
    Wei, Zhao
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1640 - 1651
  • [33] Influence of inversion time on endolymphatic hydrops evaluation in 3D-FLAIR imaging
    Eliezer, Michael
    Gillibert, Andre
    Tropres, Irene
    Krainik, Alexandre
    Attye, Arnaud
    JOURNAL OF NEURORADIOLOGY, 2017, 44 (05) : 339 - 343
  • [34] Accelerated 3D self-gated cardiac cine imaging at 3T using a tiny golden angle and compressed sensing
    Xiaoyong Zhang
    Guoxi Xie
    Hanwei Chen
    Yanchun Zhu
    Zijun Wei
    Shi Su
    Fei Yan
    Bensheng Qiu
    Xin Liu
    Zhaoyang Fan
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [35] 3D imaging of the whole spine at 3T compared to 1.5T: Initial experiences
    Rodegerdts, EA
    Boss, A
    Riemarzik, K
    Lichy, M
    Schick, F
    Claussen, CD
    Schlemmer, HP
    ACTA RADIOLOGICA, 2006, 47 (05) : 488 - 493
  • [36] Comparison of 3D Cube FLAIR with 2D FLAIR for Multiple Sclerosis Imaging at 3 Tesla
    Patzig, M.
    Burke, M.
    Brueckmann, H.
    Fesl, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (05): : 484 - 488
  • [37] MR imaging of the internal auditory canal and inner ear at 3T: Comparison between 3D driven equilibrium and 3D balanced fast field echo sequences
    Byun, Jun Soo
    Kim, Hyung-Jin
    Yim, You Jeong
    Kim, Sung Tae
    Jeon, Pyoung
    Kim, Keon Ha
    Kim, Sam Soo
    Jeon, Yong Hwan
    Lee, Jiwon
    KOREAN JOURNAL OF RADIOLOGY, 2008, 9 (03) : 212 - 218
  • [38] High-resolution 3D MR spectroscopic imaging of the prostate at 3 T with the MLEV-PRESS sequence
    Chen, Albert P.
    Cunningham, Charles H.
    Kurhanewicz, John
    Xu, Duan
    Hurd, Ralph E.
    Pauly, John M.
    Carvajal, Lucas
    Karpodinis, Kostas
    Vigneron, Daniel B.
    MAGNETIC RESONANCE IMAGING, 2006, 24 (07) : 825 - 832
  • [39] Comparison of 3D TOF-MRA and 3D CE-MRA at 3T for imaging of intracranial aneurysms
    Cirillo, Mario
    Scomazzoni, Francesco
    Cirillo, Luigi
    Cadioli, Marcello
    Simionato, Franco
    Iadanza, Antonella
    Kirchin, Miles
    Righi, Claudio
    Anzalone, Nicoletta
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : E853 - E859
  • [40] Quantitative PET imaging with the 3T MR-BrainPET
    Weirich, C.
    Scheins, J.
    Lohmann, P.
    Tellmann, L.
    Byars, L.
    Michel, C.
    Kops, E. Rota
    Brenner, D.
    Herzog, H.
    Shah, N. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 26 - 28