Evaluation of the MRI compatibility of PET detectors modules for organ-specific inserts in a 3T and 7T MRI scanner

被引:0
|
作者
Schmidt, Fabian P. [1 ,9 ]
Allen, Magdelena S. [2 ,3 ]
Ladebeck, Ralf [4 ]
Breuer, Johannes [5 ]
Judenhofer, Martin [6 ]
Schmand, Matthias [6 ]
Catana, Ciprian [2 ,7 ]
Pichler, Bernd J. [1 ,8 ]
机构
[1] Eberhard Karls Univ Tuebingen, Werner Siemens Imaging Ctr, Dept Preclin Imaging & Radiopharm, Tubingen, Germany
[2] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Charlestown, MA USA
[3] MIT, Dept Phys, Lab Nucl Sci, Cambridge, MA USA
[4] Siemens Healthcare GmbH, Magnet Resonance, Erlangen, Germany
[5] Siemens Healthcare GmbH, Mol Imaging, Forchheim, Germany
[6] Siemens Med Solut USA Inc, Mol Imaging, Knoxville, TN USA
[7] Harvard Med Sch, Boston, MA USA
[8] Univ Tubingen, Cluster Excellence iFIT EXC 2180 Image Guided & Fu, Ctr CNS Tumors, Tubingen, Germany
[9] Werner Siemens Imaging Ctr, Rontgenweg 13, D-72076 Tubingen, Germany
关键词
SILICON PHOTOMULTIPLIER PET; PET/MRI; PROTOTYPE; PRINCIPLES; SYSTEM; BRAIN; COIL;
D O I
10.1002/mp.16923
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundSimultaneous positron emission tomography (PET)/magnetic resonance imaging (MRI) scanners and inserts are valuable tools for accurate diagnosis, treatment planning, and monitoring due to their complementary information. However, the integration of a PET system into an MRI scanner presents technical challenges for a distortion-free operation.PurposeWe aim to develop a PET insert dedicated to breast imaging in combination with the 3T PET/MRI scanner Biograph mMR (Siemens Healthineers) as well as a brain PET insert for the 7T MRI scanner MAGNETOM Terra (Siemens Healthineers). For this development, we selected as a basis the C13500 series PET modules (Hamamatsu Photonics K.K.) as they offer an all-in-one solution with a scalable, modular design for compact integration with state-of-the-art performance. The original PET modules were not designed to be operated with an MRI scanner, therefore we implemented several modifications such as signal transmission via plastic optical fiber, radio frequency (RF) shielding of the front-end electronics, and filter for the power supply lines. In this work, we evaluated the mutual MRI compatibility between the modified PET modules and the 3T and 7T MRI scanner.MethodsWe used a proof-of-concept setup with two detectors to comprehensively evaluate a potential distortion of the performance of the modified PET modules whilst exposing them to a variety of MR sequences up to the peak operation conditions of the Biograph mMR. A method using the periodicity of the sequences to identify distortions of the PET events in the phase of RF pulse transmission was introduced. Vice versa, the potential distortion of the Biograph mMR was evaluated by vendor proprietary MRI compatibility test sequences. Afterwards, these studies were extended to the MAGNETOM Terra.ResultsNo distortions were introduced by gradient field switching (field strength up to 20 mT/m at a slew rate of 66.0 T/ms-1). However, RF pulse transmission induced a reduction of the single event rate from 33.0 kcounts/s to 32.0 kcounts/s and a degradation of the coincidence resolution time from 251 to 299 ps. Further, the proposed method revealed artifacts in the energy and timing histograms. Finally, by using the front-end filters it was possible to prevent any RF pulse induced distortion of event rate, energy, or time stamps even for a 700 degrees flip angle (45.5 mu T) sequence.The evaluations to assess potential distortions of the MRI scanner showed that carefully designed RF shielding boxes for the PET modules were required to prevent distortion of the RF spectra. The increase in B0 field inhomogeneity of 0.254 ppm and local changes of the B1 field of 12.5% introduced by the PET modules did not qualitatively affect the MR imaging with a spin echo and MPRAGE sequence for the Biograph mMR and the MAGNETOM Terra, respectively.ResultsNo distortions were introduced by gradient field switching (field strength up to 20 mT/m at a slew rate of 66.0 T/ms-1). However, RF pulse transmission induced a reduction of the single event rate from 33.0 kcounts/s to 32.0 kcounts/s and a degradation of the coincidence resolution time from 251 to 299 ps. Further, the proposed method revealed artifacts in the energy and timing histograms. Finally, by using the front-end filters it was possible to prevent any RF pulse induced distortion of event rate, energy, or time stamps even for a 700 degrees flip angle (45.5 mu T) sequence. The evaluations to assess potential distortions of the MRI scanner showed that carefully designed RF shielding boxes for the PET modules were required to prevent distortion of the RF spectra. The increase in B0 field inhomogeneity of 0.254 ppm and local changes of the B1 field of 12.5% introduced by the PET modules did not qualitatively affect the MR imaging with a spin echo and MPRAGE sequence for the Biograph mMR and the MAGNETOM Terra, respectively.ConclusionOur study demonstrates the feasibility of using a modified version of the PET modules in combination with 3T and 7T MRI scanners. Building upon the encouraging MRI compatibility results from our proof-of-concept detectors, we will proceed to develop PET inserts for breast and brain imaging using these modules.
引用
收藏
页码:991 / 1006
页数:16
相关论文
共 50 条
  • [41] Bone Structure Analysis of the Radius Using Ultrahigh Field (7T) MRI: Relevance of Technical Parameters and Comparison with 3T MRI and Radiography
    Jarraya, Mohamed
    Heiss, Rafael
    Duryea, Jeffrey
    Nagel, Armin M.
    Lynch, John A.
    Guermazi, Ali
    Weber, Marc-Andre
    Arkudas, Andreas
    Horch, Raymund E.
    Uder, Michael
    Roemer, Frank W.
    DIAGNOSTICS, 2021, 11 (01)
  • [42] TRABECULAR SUBCHONDRAL BONE ANALYSIS OF THE DISTAL RADIUS AT ULTRA-HIGH FIELD (7T) MRI: COMPARISON WITH 3T MRI AND RADIOGRAPHY
    Jarraya, M.
    Heiss, R.
    Duryea, J.
    Nagel, A. N.
    Lynch, J. A.
    Guermazi, A.
    Weber, M. -A.
    Arkudas, A.
    Horch, R. E.
    Uder, M.
    Roemer, F. W.
    OSTEOARTHRITIS AND CARTILAGE, 2021, 29 : S156 - S157
  • [43] Geometry optimization of electrically floating PET inserts for improved RF penetration for a 3T MRI system
    Akram, Md Shahadat Hossain
    Levin, Craig S.
    Obata, Takayuki
    Hirumi, Genki
    Yamaya, Taiga
    MEDICAL PHYSICS, 2018, 45 (10) : 4627 - 4641
  • [44] Conformance of a 3T radiotherapy MRI scanner to the QIBA Diffusion Profile
    Carr, Madeline E.
    Keenan, Kathryn E.
    Rai, Robba
    Boss, Michael A.
    Metcalfe, Peter
    Walker, Amy
    Holloway, Lois
    MEDICAL PHYSICS, 2022, 49 (07) : 4508 - 4517
  • [45] Central Vein Sign in Multiple Sclerosis: A Comparison Study of the Diagnostic Performance of 3T versus 7T MRI
    Okromelidze, Lela
    Patel, Vishal
    Singh, Rahul B.
    Chiriboga, Alfonso S. Lopez
    Tao, Shengzhen
    Zhou, Xiangzhi
    Straub, Sina
    Westerhold, Erin M.
    Gupta, Vivek
    Agarwal, Amit K.
    Murray, John V.
    Desai, Amit
    Sandhu, S. J. S.
    Collazo, I. Vanessa Marin
    Middlebrooks, Erik H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (01) : 76 - 81
  • [46] Improved depiction of hemodynamics in intracranial aneurysms by 4D flow MRI at 7T compared to 3T
    P van Ooij
    R Kleinloog
    JJ Zwanenburg
    F Visser
    P Luijten
    AJ Barker
    M Markl
    A Nederveen
    CB Majoie
    L Regli
    G Rinkel
    B Verweij
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [47] High-resolution intracranial vessel wall MRI in an elderly asymptomatic population: comparison of 3T and 7T
    Anita A. Harteveld
    Anja G. van der Kolk
    H. Bart van der Worp
    Nikki Dieleman
    Jeroen C. W. Siero
    Hugo J. Kuijf
    Catharina J. M. Frijns
    Peter R. Luijten
    Jaco J. M. Zwanenburg
    Jeroen Hendrikse
    European Radiology, 2017, 27 : 1585 - 1595
  • [48] 3T MRI detection of 7T paramagnetic rims in multiple sclerosis lesions: a step toward the clinical application
    Absinta, M.
    Sati, P.
    Fechner, A.
    Schindler, M. K.
    Reich, D. S.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 79 - 80
  • [49] Dynamic contrast-enhanced breast MRI at 7T and 3T: an intra-individual comparison study
    Menezes, Gisela L. G.
    Stehouwer, Bertine L.
    Klomp, Dennis W. J.
    van der Velden, Tijl A.
    van den Bosch, Maurice A. A. J.
    Knuttel, Floortje M.
    Boer, Vincent O.
    van der Kemp, Wybe J. M.
    Luijten, Peter R.
    Veldhuis, Wouter B.
    SPRINGERPLUS, 2016, 5 : 1 - 12
  • [50] Comparison of Paramagnetic Rim Lesions Identified on Quantitative Susceptibility Mapping and Phase Maps on 7T and 3T MRI
    Choi, Seongjin
    Li, Xu
    Zhuo, Jiachen
    Harrison, Daniel
    MULTIPLE SCLEROSIS JOURNAL, 2024, 30 (03) : 283 - 284