Evaluation of the MRI compatibility of PET detectors modules for organ-specific inserts in a 3T and 7T MRI scanner

被引:0
|
作者
Schmidt, Fabian P. [1 ,9 ]
Allen, Magdelena S. [2 ,3 ]
Ladebeck, Ralf [4 ]
Breuer, Johannes [5 ]
Judenhofer, Martin [6 ]
Schmand, Matthias [6 ]
Catana, Ciprian [2 ,7 ]
Pichler, Bernd J. [1 ,8 ]
机构
[1] Eberhard Karls Univ Tuebingen, Werner Siemens Imaging Ctr, Dept Preclin Imaging & Radiopharm, Tubingen, Germany
[2] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Charlestown, MA USA
[3] MIT, Dept Phys, Lab Nucl Sci, Cambridge, MA USA
[4] Siemens Healthcare GmbH, Magnet Resonance, Erlangen, Germany
[5] Siemens Healthcare GmbH, Mol Imaging, Forchheim, Germany
[6] Siemens Med Solut USA Inc, Mol Imaging, Knoxville, TN USA
[7] Harvard Med Sch, Boston, MA USA
[8] Univ Tubingen, Cluster Excellence iFIT EXC 2180 Image Guided & Fu, Ctr CNS Tumors, Tubingen, Germany
[9] Werner Siemens Imaging Ctr, Rontgenweg 13, D-72076 Tubingen, Germany
关键词
SILICON PHOTOMULTIPLIER PET; PET/MRI; PROTOTYPE; PRINCIPLES; SYSTEM; BRAIN; COIL;
D O I
10.1002/mp.16923
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundSimultaneous positron emission tomography (PET)/magnetic resonance imaging (MRI) scanners and inserts are valuable tools for accurate diagnosis, treatment planning, and monitoring due to their complementary information. However, the integration of a PET system into an MRI scanner presents technical challenges for a distortion-free operation.PurposeWe aim to develop a PET insert dedicated to breast imaging in combination with the 3T PET/MRI scanner Biograph mMR (Siemens Healthineers) as well as a brain PET insert for the 7T MRI scanner MAGNETOM Terra (Siemens Healthineers). For this development, we selected as a basis the C13500 series PET modules (Hamamatsu Photonics K.K.) as they offer an all-in-one solution with a scalable, modular design for compact integration with state-of-the-art performance. The original PET modules were not designed to be operated with an MRI scanner, therefore we implemented several modifications such as signal transmission via plastic optical fiber, radio frequency (RF) shielding of the front-end electronics, and filter for the power supply lines. In this work, we evaluated the mutual MRI compatibility between the modified PET modules and the 3T and 7T MRI scanner.MethodsWe used a proof-of-concept setup with two detectors to comprehensively evaluate a potential distortion of the performance of the modified PET modules whilst exposing them to a variety of MR sequences up to the peak operation conditions of the Biograph mMR. A method using the periodicity of the sequences to identify distortions of the PET events in the phase of RF pulse transmission was introduced. Vice versa, the potential distortion of the Biograph mMR was evaluated by vendor proprietary MRI compatibility test sequences. Afterwards, these studies were extended to the MAGNETOM Terra.ResultsNo distortions were introduced by gradient field switching (field strength up to 20 mT/m at a slew rate of 66.0 T/ms-1). However, RF pulse transmission induced a reduction of the single event rate from 33.0 kcounts/s to 32.0 kcounts/s and a degradation of the coincidence resolution time from 251 to 299 ps. Further, the proposed method revealed artifacts in the energy and timing histograms. Finally, by using the front-end filters it was possible to prevent any RF pulse induced distortion of event rate, energy, or time stamps even for a 700 degrees flip angle (45.5 mu T) sequence.The evaluations to assess potential distortions of the MRI scanner showed that carefully designed RF shielding boxes for the PET modules were required to prevent distortion of the RF spectra. The increase in B0 field inhomogeneity of 0.254 ppm and local changes of the B1 field of 12.5% introduced by the PET modules did not qualitatively affect the MR imaging with a spin echo and MPRAGE sequence for the Biograph mMR and the MAGNETOM Terra, respectively.ResultsNo distortions were introduced by gradient field switching (field strength up to 20 mT/m at a slew rate of 66.0 T/ms-1). However, RF pulse transmission induced a reduction of the single event rate from 33.0 kcounts/s to 32.0 kcounts/s and a degradation of the coincidence resolution time from 251 to 299 ps. Further, the proposed method revealed artifacts in the energy and timing histograms. Finally, by using the front-end filters it was possible to prevent any RF pulse induced distortion of event rate, energy, or time stamps even for a 700 degrees flip angle (45.5 mu T) sequence. The evaluations to assess potential distortions of the MRI scanner showed that carefully designed RF shielding boxes for the PET modules were required to prevent distortion of the RF spectra. The increase in B0 field inhomogeneity of 0.254 ppm and local changes of the B1 field of 12.5% introduced by the PET modules did not qualitatively affect the MR imaging with a spin echo and MPRAGE sequence for the Biograph mMR and the MAGNETOM Terra, respectively.ConclusionOur study demonstrates the feasibility of using a modified version of the PET modules in combination with 3T and 7T MRI scanners. Building upon the encouraging MRI compatibility results from our proof-of-concept detectors, we will proceed to develop PET inserts for breast and brain imaging using these modules.
引用
收藏
页码:991 / 1006
页数:16
相关论文
共 50 条
  • [21] Wireless video transmission into the MRI magnet room: implementation and evaluation at 1.5T, 3T and 7T
    Hensen, Bennet
    Kaegebein, Urte
    Gutberlet, Marcel
    Ringe, Kristina, I
    Van Dai Vo-Chieu
    Stucht, Daniel
    Speck, Oliver
    Vick, Ralf
    Wacker, Frank
    Pannicke, Enrico
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2019, 64 (04): : 373 - 382
  • [22] 7T MRI is More Sensitive to Leptomeningeal Contrast Enhancement in MS than 3T MRI: a Direct Comparison
    Araujo, D.
    Fetco, D.
    Arnaoutelis, R.
    Tagge, I. J.
    Rudko, D. A.
    Arnold, D. L.
    Narayanan, S.
    MULTIPLE SCLEROSIS JOURNAL, 2022, 28 (1_SUPPL) : 117 - 118
  • [23] A 7T MRI-Guided Learning Method for Automatic Hippocampal Subfield Segmentation on Routine 3T MRI
    Wang, Linjin
    He, Jiangtao
    Geng, Guohong
    Zhong, Lisha
    Li, Xinwei
    IEEE ACCESS, 2025, 13 : 42428 - 42440
  • [24] Digging deep in 7T MRI: potential epileptogenic and surgical lesions in epilepsy patients with nonlesional 3T MRI
    Chalia, Mayur
    Panda, Ananya
    Brinkmann, Benjamin
    Britton, Jeffrey
    Messina, Steven
    Krecke, Karl
    Witte, Robert
    Welker, Kirk
    Wong-Kisiel, Lily
    EPILEPSIA, 2021, 62 : 229 - 230
  • [25] Comparison of 3T and 7T MRI for the visualization of globus pallidus sub-segments
    Shuki Maruyama
    Masaki Fukunaga
    Hans-Peter Fautz
    Robin Heidemann
    Norihiro Sadato
    Scientific Reports, 9
  • [26] Comparison of 3T and 7T MRI for the visualization of globus pallidus sub-segments
    Maruyama, Shuki
    Fukunaga, Masaki
    Fautz, Hans-Peter
    Heidemann, Robin
    Sadato, Norihiro
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [27] Dual-Domain Cascaded Regression for Synthesizing 7T from 3T MRI
    Zhang, Yongqin
    Cheng, Jie-Zhi
    Xiang, Lei
    Yap, Pew-Thian
    Shen, Dinggang
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT I, 2018, 11070 : 410 - 417
  • [28] Evaluation of postcontrast images of intracranial tumors at 7T and 3T MRI: An intra-individual comparison study
    Cheng, Kun
    Duan, Qi
    Hu, Jianxing
    Li, Chenxi
    Ma, Xiaoxiao
    Bian, Xiangbing
    Duan, Caohui
    Xiong, Yongqin
    Lin, Jiaji
    Lu, Haoxuan
    Deng, Linlin
    Li, Ze
    Wei, Mengting
    Lyu, Jinhao
    Chen, Ling
    Lou, Xin
    CNS NEUROSCIENCE & THERAPEUTICS, 2023, 29 (02) : 559 - 565
  • [29] No Increased Mercury Release from Dental Restorations at 1.5T, 3T, or 7T MRI
    Burkett, Brian J.
    Rasmussen, Chad M.
    Fillmore, W. Jonathan
    McDonald, Jennifer S.
    McDonald, Robert J.
    Fagan, Andrew J.
    Erdahl, Sarah A.
    Eckdahl, Steven J.
    Welker, Kirk M.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 660 - 669
  • [30] Comparison of Multiple Sclerosis Cortical Lesion Types Detected by Multicontrast 3T and 7T MRI
    Maranzano, J.
    Dadar, M.
    Rudko, D. A.
    De Nigris, D.
    Elliott, C.
    Gati, J. S.
    Morrow, S. A.
    Menon, R. S.
    Collins, D. L.
    Arnold, D. L.
    Narayanan, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (07) : 1162 - 1169