Evaluation of the MRI compatibility of PET detectors modules for organ-specific inserts in a 3T and 7T MRI scanner

被引:0
|
作者
Schmidt, Fabian P. [1 ,9 ]
Allen, Magdelena S. [2 ,3 ]
Ladebeck, Ralf [4 ]
Breuer, Johannes [5 ]
Judenhofer, Martin [6 ]
Schmand, Matthias [6 ]
Catana, Ciprian [2 ,7 ]
Pichler, Bernd J. [1 ,8 ]
机构
[1] Eberhard Karls Univ Tuebingen, Werner Siemens Imaging Ctr, Dept Preclin Imaging & Radiopharm, Tubingen, Germany
[2] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Charlestown, MA USA
[3] MIT, Dept Phys, Lab Nucl Sci, Cambridge, MA USA
[4] Siemens Healthcare GmbH, Magnet Resonance, Erlangen, Germany
[5] Siemens Healthcare GmbH, Mol Imaging, Forchheim, Germany
[6] Siemens Med Solut USA Inc, Mol Imaging, Knoxville, TN USA
[7] Harvard Med Sch, Boston, MA USA
[8] Univ Tubingen, Cluster Excellence iFIT EXC 2180 Image Guided & Fu, Ctr CNS Tumors, Tubingen, Germany
[9] Werner Siemens Imaging Ctr, Rontgenweg 13, D-72076 Tubingen, Germany
关键词
SILICON PHOTOMULTIPLIER PET; PET/MRI; PROTOTYPE; PRINCIPLES; SYSTEM; BRAIN; COIL;
D O I
10.1002/mp.16923
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundSimultaneous positron emission tomography (PET)/magnetic resonance imaging (MRI) scanners and inserts are valuable tools for accurate diagnosis, treatment planning, and monitoring due to their complementary information. However, the integration of a PET system into an MRI scanner presents technical challenges for a distortion-free operation.PurposeWe aim to develop a PET insert dedicated to breast imaging in combination with the 3T PET/MRI scanner Biograph mMR (Siemens Healthineers) as well as a brain PET insert for the 7T MRI scanner MAGNETOM Terra (Siemens Healthineers). For this development, we selected as a basis the C13500 series PET modules (Hamamatsu Photonics K.K.) as they offer an all-in-one solution with a scalable, modular design for compact integration with state-of-the-art performance. The original PET modules were not designed to be operated with an MRI scanner, therefore we implemented several modifications such as signal transmission via plastic optical fiber, radio frequency (RF) shielding of the front-end electronics, and filter for the power supply lines. In this work, we evaluated the mutual MRI compatibility between the modified PET modules and the 3T and 7T MRI scanner.MethodsWe used a proof-of-concept setup with two detectors to comprehensively evaluate a potential distortion of the performance of the modified PET modules whilst exposing them to a variety of MR sequences up to the peak operation conditions of the Biograph mMR. A method using the periodicity of the sequences to identify distortions of the PET events in the phase of RF pulse transmission was introduced. Vice versa, the potential distortion of the Biograph mMR was evaluated by vendor proprietary MRI compatibility test sequences. Afterwards, these studies were extended to the MAGNETOM Terra.ResultsNo distortions were introduced by gradient field switching (field strength up to 20 mT/m at a slew rate of 66.0 T/ms-1). However, RF pulse transmission induced a reduction of the single event rate from 33.0 kcounts/s to 32.0 kcounts/s and a degradation of the coincidence resolution time from 251 to 299 ps. Further, the proposed method revealed artifacts in the energy and timing histograms. Finally, by using the front-end filters it was possible to prevent any RF pulse induced distortion of event rate, energy, or time stamps even for a 700 degrees flip angle (45.5 mu T) sequence.The evaluations to assess potential distortions of the MRI scanner showed that carefully designed RF shielding boxes for the PET modules were required to prevent distortion of the RF spectra. The increase in B0 field inhomogeneity of 0.254 ppm and local changes of the B1 field of 12.5% introduced by the PET modules did not qualitatively affect the MR imaging with a spin echo and MPRAGE sequence for the Biograph mMR and the MAGNETOM Terra, respectively.ResultsNo distortions were introduced by gradient field switching (field strength up to 20 mT/m at a slew rate of 66.0 T/ms-1). However, RF pulse transmission induced a reduction of the single event rate from 33.0 kcounts/s to 32.0 kcounts/s and a degradation of the coincidence resolution time from 251 to 299 ps. Further, the proposed method revealed artifacts in the energy and timing histograms. Finally, by using the front-end filters it was possible to prevent any RF pulse induced distortion of event rate, energy, or time stamps even for a 700 degrees flip angle (45.5 mu T) sequence. The evaluations to assess potential distortions of the MRI scanner showed that carefully designed RF shielding boxes for the PET modules were required to prevent distortion of the RF spectra. The increase in B0 field inhomogeneity of 0.254 ppm and local changes of the B1 field of 12.5% introduced by the PET modules did not qualitatively affect the MR imaging with a spin echo and MPRAGE sequence for the Biograph mMR and the MAGNETOM Terra, respectively.ConclusionOur study demonstrates the feasibility of using a modified version of the PET modules in combination with 3T and 7T MRI scanners. Building upon the encouraging MRI compatibility results from our proof-of-concept detectors, we will proceed to develop PET inserts for breast and brain imaging using these modules.
引用
收藏
页码:991 / 1006
页数:16
相关论文
共 50 条
  • [31] Atherosclerotic Carotid Plaque Composition: A 3T and 7T MRI-Histology Correlation Study
    Gonzalez, M. R. Lopez
    Foo, S. Y.
    Holmes, W. M.
    Stewart, W.
    Muir, K. W.
    Condon, B.
    Welch, G.
    Forbes, K. P.
    JOURNAL OF NEUROIMAGING, 2016, 26 (04) : 406 - 413
  • [32] Experience with the Set-Up of a 7T Clinical MRI Scanner
    Fagan, A.
    Watson, R.
    Carlson, S.
    Amrami, K.
    Welker, K.
    Felmlee, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E419 - E420
  • [33] NEMA Performance Evaluation of Long Axial Field-of-View Brain PET Insert with 7T MRI Compatibility
    Park, Haewook
    Lee, Seungeun
    Won, Jun Yeon
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [34] Calorimetric Calibration of Specific Absorption Rate (SAR) On a Compact 3T MRI Scanner
    Shu, Y.
    Tao, S.
    Yeo, D.
    Foo, T.
    Weavers, P.
    Trzasko, J.
    Huston, J.
    Bernstein, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3048 - 3048
  • [35] Electromagnetic Exposure of Personnel Involved in Cardiac MRI Examinations in 1.5T, 3T and 7T Scanners
    Sklinda, Katarzyna
    Karpowicz, Jolanta
    Stepniewski, Andrzej
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (01)
  • [36] Occult Amyloid-β-Related Angiitis: Neuroimaging Findings at 1.5T, 3T, and 7T MRI
    Ozutemiz, Can
    Hussein, Haitham M.
    Ikramuddin, Salman
    Clark, H. Brent
    Charidimou, Andreas
    Streib, Christopher
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (08) : 1013 - 1018
  • [37] Quantitative Comparison Between 3T and 7T MRI for Detection of Head and Neck Cancer for MRI-Based Treatment Planning
    Lee, M.
    Song, K.
    Choe, B.
    Suh, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E190 - E190
  • [38] Numerical Design of Dual Resonant Phased Array RF Coil for MRI 3T and 7T System
    Basari
    Yuliyanti, Sri
    Rahardjo, Eko Tjipto
    Zulkifli, Fitri Yuli
    2015 2ND INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY, COMPUTER, AND ELECTRICAL ENGINEERING (ICITACEE), 2015, : 275 - 278
  • [39] Comparing ultra-high Field 7T to 3T MRI in a paediatric focal epilepsy cohort
    Vecchiato, K.
    Casella, C.
    Dokumaci, A. S.
    Bridgen, P.
    Egloff, A.
    Siddiqui, A.
    Jarosz, J.
    Colford, K.
    Singh, R.
    Tomi-Tricot, R.
    Wilkinson, T.
    Malik, S.
    Hajnal, J.
    Giles, S. L.
    Hammers, A.
    Carmichael, D.
    O'Muircheartaigh, J.
    EPILEPSIA, 2023, 64 : 134 - 134
  • [40] MRI compatibility study of an integrated PET/RF-coil prototype system at 3T
    Akram, Md Shahadat Hossain
    Obata, Takayuki
    Suga, Mikio
    Nishikido, Fumihiko
    Yoshida, Eiji
    Saito, Kazuyuki
    Yamaya, Taiga
    JOURNAL OF MAGNETIC RESONANCE, 2017, 283 : 62 - 70