False Lumen Intercostal Artery Embolization to Halt Type R Entry Flow in Chronic Type B Aortic Dissection

被引:0
|
作者
Yi, Jeniann A. [1 ,4 ]
Magee, Gregory A. [2 ]
Potter, Helen A. [2 ]
Kuwayama, David P. [3 ]
机构
[1] Univ Colorado, Dept Surg, Div Vasc Surg & Endovasc Therapy, Aurora, CO USA
[2] Univ Southern Calif, Dept Surg, Div Vasc Surg & Endovasc Therapy, Los Angeles, CA USA
[3] Dartmouth Hitchcock Med Ctr, Dept Surg, Sect Vasc Surg, Lebanon, NH USA
[4] Univ Colorado, Anschutz Med Campus,12631 E 17th Ave,MC C312 Room, Aurora, CO 80045 USA
关键词
ENDOVASCULAR REPAIR; SPINAL-CORD; COIL EMBOLIZATION; THROMBOSIS; PREDICTORS;
D O I
10.1016/j.avsg.2022.07.023
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Treatment of aneurysmal type B aortic dissection often involves thoracic endovascular aortic repair (TEVAR). However, persistent patency of the false lumen from type R entry flow is common and is associated with late complications including rupture. We describe 9 patients with aneurysmal chronic type B aortic dissections and patent false lumens and 7 despite prior thoracic endovascular aortic repair. The goal of the false lumen intercostal embolization in these patients was to achieve propagation of false lumen thrombosis (FLT) and to prevent spinal cord ischemia (SCI) using a staged approach in the overall treatment of their complex aortic aneurysm.Methods: A multicenter retrospective review was performed of all consecutive false lumen intercostal embolization procedures; 9 were identified. Preoperative and postoperative computed tomographic angiograms were compared. We hypothesized that embolization was a safe and feasible treatment option. The primary outcome was procedural characteristics and SCI to establish safety and feasibility. Secondary outcomes included a change in supraceliac patent false lumen length and other perioperative clinical outcomes.Results: In total, 30 of 31 (97%) targeted false lumen intercostal arteries were successfully coiled. Median procedural time was 57 min (interquartile range [IQR] 23-99), median air kerma was 585 mGy (IQR 398-1,644), and median contrast dose was 141 mL (IQR 74-240). After embolization, all patients demonstrated propagation of FLT, with mean false lumen length decreasing by 48% from 13.8 cm to 6.6 cm. There was no mortality associated with this procedure; 2 patients suffered a lumbar drain-related complication; 1 with cerebrospinal fluid leak and 1 with a spinal hematoma that was managed conservatively with no neurological deficit. No other complications occurred.Conclusions: In this review, false lumen intercostal coil embolization was technically feasible and did not result in any cases of SCI. The procedures required acceptable amounts of operative time, fluoroscopic dose, and contrast. All patients experienced propagation of FLT and no longterm procedure-related morbidity was noted. More data will be required to ascertain whether this procedure is effective at halting type R entry flow, preventing future type II entry flow, and promoting aortic remodeling over time.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [41] Flow dynamics in the false lumen in distal aorta following surgery for type A aortic dissection
    Desai, Dhaval
    Miranda, William
    Connolly, Heidi
    Tajik, A. Jamil
    EUROPEAN HEART JOURNAL, 2019, 40 (06) : 561 - 561
  • [42] Modified candy-plug device for aneurysmal false lumen occlusion in chronic type B aortic dissection
    Wu, I-Hui
    Chan, Chih-Yang
    Luo, Chien-Ming
    Wang, Shoei-Shen
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (05): : 1970 - +
  • [43] Percutaneous renal denervation through a false lumen fenestration in aortic dissection type B
    Ewen, S.
    Mahfoud, F.
    Boehm, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 1133 - 1133
  • [44] Influence of tear configuration on false and true lumen haemodynamics in type B aortic dissection
    Rudenick, Paula A.
    Bordone, Maurizio
    Bijnens, Bart H.
    Soudah, Eduardo
    Onate, Eugenio
    Garcia-Dorado, David
    Evangelista, Arturo
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 2509 - 2512
  • [45] Left atrial collapse due to a giant false lumen in type B aortic dissection
    Rodolfo San Antonio
    Eduardo Josué Flores Umanzor
    Paula Sánchez Somonte
    Guillem Caldentey
    Intensive Care Medicine, 2017, 43 : 133 - 134
  • [46] Left atrial collapse due to a giant false lumen in type B aortic dissection
    San Antonio, Rodolfo
    Flores Umanzor, Eduardo Josue
    Sanchez Somonte, Paula
    Caldentey, Guillem
    INTENSIVE CARE MEDICINE, 2017, 43 (01) : 133 - 134
  • [47] The Prevalence of Sleep Apnea in Type B Aortic Dissection: Implications for False Lumen Thrombosis
    Wang, Ling
    Chen, Jiyan
    Li, Guangxi
    Luo, Songyuan
    Wang, Rui
    Li, Wei
    Zhang, Jiawei
    Liu, Yuan
    Huang, Wenhui
    Cao, Yingshu
    Zhou, Yingling
    Chen, Pingyan
    Pressman, Gregg S.
    Somers, Virend K.
    Luo, Jianfang
    SLEEP, 2017, 40 (03)
  • [48] Successful Endovascular Correction of an Endograft Connected with the False Lumen of a Type B Aortic Dissection
    Delclaux, Nicolas
    Sobocinski, Jonathan
    Maurel, Blandine
    Le Roux, Marielle
    Tyrrell, Mark R.
    Azzaoui, Richard
    Haulon, Stephan
    ANNALS OF VASCULAR SURGERY, 2014, 28 (08) : 1935.e7 - 1935.e11
  • [49] Fate and Consequences of the False Lumen After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection
    Jubouri, Matti
    Patel, Ravi
    Tan, Sven Z. C. P.
    Al-Tawil, Mohammed
    Bashir, Mohamad
    Bailey, Damian M.
    Williams, Ian M.
    ANNALS OF VASCULAR SURGERY, 2023, 94 : 32 - 37
  • [50] Outflow Through Aortic Side Branches Drives False Lumen Patency in Type B Aortic Dissection
    Logghe, Gerlinde
    Trachet, Bram
    Segers, Patrick
    De Backer, Julie
    Mulorz, Joscha
    Dueppers, Philip
    Vermassen, Frank
    Schelzig, Hubert
    Van Herzeele, Isabelle
    Wagenhauser, Markus U.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8