Background: Treatment of aneurysmal type B aortic dissection often involves thoracic endovascular aortic repair (TEVAR). However, persistent patency of the false lumen from type R entry flow is common and is associated with late complications including rupture. We describe 9 patients with aneurysmal chronic type B aortic dissections and patent false lumens and 7 despite prior thoracic endovascular aortic repair. The goal of the false lumen intercostal embolization in these patients was to achieve propagation of false lumen thrombosis (FLT) and to prevent spinal cord ischemia (SCI) using a staged approach in the overall treatment of their complex aortic aneurysm.Methods: A multicenter retrospective review was performed of all consecutive false lumen intercostal embolization procedures; 9 were identified. Preoperative and postoperative computed tomographic angiograms were compared. We hypothesized that embolization was a safe and feasible treatment option. The primary outcome was procedural characteristics and SCI to establish safety and feasibility. Secondary outcomes included a change in supraceliac patent false lumen length and other perioperative clinical outcomes.Results: In total, 30 of 31 (97%) targeted false lumen intercostal arteries were successfully coiled. Median procedural time was 57 min (interquartile range [IQR] 23-99), median air kerma was 585 mGy (IQR 398-1,644), and median contrast dose was 141 mL (IQR 74-240). After embolization, all patients demonstrated propagation of FLT, with mean false lumen length decreasing by 48% from 13.8 cm to 6.6 cm. There was no mortality associated with this procedure; 2 patients suffered a lumbar drain-related complication; 1 with cerebrospinal fluid leak and 1 with a spinal hematoma that was managed conservatively with no neurological deficit. No other complications occurred.Conclusions: In this review, false lumen intercostal coil embolization was technically feasible and did not result in any cases of SCI. The procedures required acceptable amounts of operative time, fluoroscopic dose, and contrast. All patients experienced propagation of FLT and no longterm procedure-related morbidity was noted. More data will be required to ascertain whether this procedure is effective at halting type R entry flow, preventing future type II entry flow, and promoting aortic remodeling over time.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [31] Residual flow in false lumen of chronic descending aortic dissection
    M. Boulaksil
    S. S. Liem
    M. Akarkach
    J. Timmermans
    Netherlands Heart Journal, 2018, 26 : 50 - 51
  • [32] Residual flow in false lumen of chronic descending aortic dissection
    Boulaksil, M.
    Liem, S. S.
    Akarkach, M.
    Timmermans, J.
    NETHERLANDS HEART JOURNAL, 2018, 26 (01) : 50 - +
  • [33] Penetration of Dissected Membrane for False Lumen Embolization in a Case of Chronic Aortic Dissection
    Ichihashi, Shigeo
    Nagatomi, Satoru
    Iwakoshi, Shinichi
    Hirose, Tomoaki
    Bolstad, Francesco
    Kichikawa, Kimihiko
    VASCULAR AND ENDOVASCULAR SURGERY, 2022, 56 (01) : 80 - 84
  • [34] Impact of Endovascular False Lumen Embolization on Thoracic Aortic Remodeling in Chronic Dissection
    Miletic, Kyle G.
    Kindzelski, Bogdan A.
    Hodges, Kevin E.
    Beach, Jocelyn
    Tong, Michael Z.
    Bakaeen, Faisal
    Johnston, Douglas R.
    Desai, Milind
    Lyden, Sean
    Roselli, Eric E.
    ANNALS OF THORACIC SURGERY, 2021, 111 (02): : 495 - 501
  • [35] Spontaneous true lumen expansion in chronic type B aortic dissection
    Kawamura, Masashi
    Monta, Osamu
    EUROPEAN HEART JOURNAL, 2021, 42 (42) : 4403 - 4403
  • [36] Proximal false lumen thrombosis is associated with low false lumen pressure and fewer complications in type B aortic dissection
    Parker, Louis P.
    Reutersberg, Benedikt
    Syed, Maaz B. J.
    Munshi, Bijit
    Richards, Samantha
    Kelsey, Lachlan J.
    Sakalihasan, Natzi
    Eckstein, Hans-Henning
    Norman, Paul E.
    Doyle, Barry J.
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (04) : 1181 - +
  • [37] Acute type A aortic dissection and the consequences of a patent false lumen
    White, Abigail
    Bozso, Sabin J.
    Ouzounian, Maral
    Chu, Michael W. A.
    Moon, Michael C.
    JTCVS TECHNIQUES, 2021, 9 : 1 - 8
  • [38] Inducing false lumen thrombosis for retrograde type A aortic dissection
    Zhang, Rongjie
    Zhou, Jian
    Feng, Jiaxuan
    Zhao, Zhiqing
    Liu, Junjun
    Li, Zhenjiang
    Feng, Rui
    Jing, Zaiping
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (01): : 57 - 65
  • [39] Coil Embolization of Persistent False Lumen After Type A Dissection Repair
    Zink, Jill N.
    Maness, Mandy R.
    Powell, Charles S.
    Parker, Frank. M.
    Bogey, William M.
    Stoner, Michael C.
    Anderson, Curtis A.
    ANNALS OF THORACIC SURGERY, 2014, 97 (06): : 2193 - 2196
  • [40] Predictors for outcome in type A aortic dissection: A focus on false lumen
    Santamaria, Valeria
    Schirone, Leonardo
    Vinciguerra, Mattia
    De Bellis, Antonio
    Greco, Ernesto
    CIRUGIA CARDIOVASCULAR, 2021, 28 (02): : 71 - 76