False Lumen Intercostal Artery Embolization to Halt Type R Entry Flow in Chronic Type B Aortic Dissection

被引:0
|
作者
Yi, Jeniann A. [1 ,4 ]
Magee, Gregory A. [2 ]
Potter, Helen A. [2 ]
Kuwayama, David P. [3 ]
机构
[1] Univ Colorado, Dept Surg, Div Vasc Surg & Endovasc Therapy, Aurora, CO USA
[2] Univ Southern Calif, Dept Surg, Div Vasc Surg & Endovasc Therapy, Los Angeles, CA USA
[3] Dartmouth Hitchcock Med Ctr, Dept Surg, Sect Vasc Surg, Lebanon, NH USA
[4] Univ Colorado, Anschutz Med Campus,12631 E 17th Ave,MC C312 Room, Aurora, CO 80045 USA
关键词
ENDOVASCULAR REPAIR; SPINAL-CORD; COIL EMBOLIZATION; THROMBOSIS; PREDICTORS;
D O I
10.1016/j.avsg.2022.07.023
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Treatment of aneurysmal type B aortic dissection often involves thoracic endovascular aortic repair (TEVAR). However, persistent patency of the false lumen from type R entry flow is common and is associated with late complications including rupture. We describe 9 patients with aneurysmal chronic type B aortic dissections and patent false lumens and 7 despite prior thoracic endovascular aortic repair. The goal of the false lumen intercostal embolization in these patients was to achieve propagation of false lumen thrombosis (FLT) and to prevent spinal cord ischemia (SCI) using a staged approach in the overall treatment of their complex aortic aneurysm.Methods: A multicenter retrospective review was performed of all consecutive false lumen intercostal embolization procedures; 9 were identified. Preoperative and postoperative computed tomographic angiograms were compared. We hypothesized that embolization was a safe and feasible treatment option. The primary outcome was procedural characteristics and SCI to establish safety and feasibility. Secondary outcomes included a change in supraceliac patent false lumen length and other perioperative clinical outcomes.Results: In total, 30 of 31 (97%) targeted false lumen intercostal arteries were successfully coiled. Median procedural time was 57 min (interquartile range [IQR] 23-99), median air kerma was 585 mGy (IQR 398-1,644), and median contrast dose was 141 mL (IQR 74-240). After embolization, all patients demonstrated propagation of FLT, with mean false lumen length decreasing by 48% from 13.8 cm to 6.6 cm. There was no mortality associated with this procedure; 2 patients suffered a lumbar drain-related complication; 1 with cerebrospinal fluid leak and 1 with a spinal hematoma that was managed conservatively with no neurological deficit. No other complications occurred.Conclusions: In this review, false lumen intercostal coil embolization was technically feasible and did not result in any cases of SCI. The procedures required acceptable amounts of operative time, fluoroscopic dose, and contrast. All patients experienced propagation of FLT and no longterm procedure-related morbidity was noted. More data will be required to ascertain whether this procedure is effective at halting type R entry flow, preventing future type II entry flow, and promoting aortic remodeling over time.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [11] Open and endovascular reinterventions after Candy Plug false lumen embolization of type B aortic dissection
    Loschi, Diletta
    Santoro, Annarita
    Rinaldi, Enrico
    Anselmi, Claudia
    Grignani, Camilla
    Chiesa, Roberto
    Melissano, Germano
    JOURNAL OF VASCULAR SURGERY, 2023, 78 (06) : 1409 - 1417
  • [12] Coil embolization of persistent false lumen after stent graft repair of type B aortic dissection
    San Norberto, Enrique Maria
    Manuel Gutierrez, Vicente
    Taylor, James
    Vaquero, Carlos
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (01) : 201 - 204
  • [13] A Case Report of Type B Aortic Dissection With Ruptured False Lumen
    Suthar, Pokhraj P.
    Hussein, Mohamed Z.
    Gaddikeri, Ramya
    Shah, Palmi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [14] Factors Affecting False Lumen Thrombosis In Type B Aortic Dissection
    Tang, Qian-hui
    Chen, Jing
    Yang, Han
    Qin, Zhong
    Lin, Qiu-ning
    Qin, Xiao
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2023, 120 (08)
  • [15] Coil Embolization for Persistent Thoracic False Lumen of Type B Aortic Dissection after Thoracic Endovascular Aortic Repair
    Zhang, Hong
    Ge, Yang Yang
    Lu, Kai
    Cao, Long
    Liu, Peng
    Liu, Xiao Ping
    Wang, Li Jun
    Guo, Wei
    ANNALS OF VASCULAR SURGERY, 2019, 57 : 60 - 68
  • [16] Importance of false lumen thrombosis in type B aortic dissection prognosis
    Trimarchi, Santi
    Tolenaar, Jip L.
    Jonker, Frederik H. W.
    Murray, Brian
    Tsai, Thomas T.
    Eagle, Kim A.
    Rampoldi, Vincenzo
    Verhagen, Hence J. M.
    van Herwaarden, Joost A.
    Moll, Frans L.
    Muhs, Bart E.
    Elefteriades, John A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (03): : S208 - S212
  • [17] Protective biomechanical and histological changes in the false lumen wall in chronic type B aortic dissection
    Dong, Hai
    Liu, Minliang
    Cebull, Hannah L.
    Chhabra, Arshiya
    Zhou, Yumeng
    Piccinelli, Marina
    Oshinski, John N.
    Elefteriades, John A.
    Gleason, Rudolph L.
    Leshnower, Bradley G.
    JTCVS OPEN, 2025, 23 : 60 - 68
  • [18] Relationship between false lumen morphology and entry tear in acute type A aortic dissection
    Furui, Masato
    Uesugi, Noriko
    Matsumura, Hitoshi
    Hayashida, Yoshio
    Kuwahara, Go
    Fujii, Mitsuru
    Shimizu, Masayuki
    Morita, Yuichi
    Ito, Chihaya
    Hayama, Masato
    Wada, Hideichi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2024, 65 (02)
  • [19] Coil embolization for persistent false lumen in type B aortic dissection: A single-center retrospective study
    Li, Zilin
    Zhang, Jinglong
    Yu, Liming
    Zuo, Jian
    ASIAN JOURNAL OF SURGERY, 2024, 47 (12) : 5462 - 5463
  • [20] Expansion of False Lumen Led to Rapid Aortic Enlargement in Type B Aortic Dissection
    Matsushita, Akihito
    Hattori, Takashi
    Mihara, Wahei
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E63 - E64