False Lumen Intercostal Artery Embolization to Halt Type R Entry Flow in Chronic Type B Aortic Dissection

被引:0
|
作者
Yi, Jeniann A. [1 ,4 ]
Magee, Gregory A. [2 ]
Potter, Helen A. [2 ]
Kuwayama, David P. [3 ]
机构
[1] Univ Colorado, Dept Surg, Div Vasc Surg & Endovasc Therapy, Aurora, CO USA
[2] Univ Southern Calif, Dept Surg, Div Vasc Surg & Endovasc Therapy, Los Angeles, CA USA
[3] Dartmouth Hitchcock Med Ctr, Dept Surg, Sect Vasc Surg, Lebanon, NH USA
[4] Univ Colorado, Anschutz Med Campus,12631 E 17th Ave,MC C312 Room, Aurora, CO 80045 USA
关键词
ENDOVASCULAR REPAIR; SPINAL-CORD; COIL EMBOLIZATION; THROMBOSIS; PREDICTORS;
D O I
10.1016/j.avsg.2022.07.023
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Treatment of aneurysmal type B aortic dissection often involves thoracic endovascular aortic repair (TEVAR). However, persistent patency of the false lumen from type R entry flow is common and is associated with late complications including rupture. We describe 9 patients with aneurysmal chronic type B aortic dissections and patent false lumens and 7 despite prior thoracic endovascular aortic repair. The goal of the false lumen intercostal embolization in these patients was to achieve propagation of false lumen thrombosis (FLT) and to prevent spinal cord ischemia (SCI) using a staged approach in the overall treatment of their complex aortic aneurysm.Methods: A multicenter retrospective review was performed of all consecutive false lumen intercostal embolization procedures; 9 were identified. Preoperative and postoperative computed tomographic angiograms were compared. We hypothesized that embolization was a safe and feasible treatment option. The primary outcome was procedural characteristics and SCI to establish safety and feasibility. Secondary outcomes included a change in supraceliac patent false lumen length and other perioperative clinical outcomes.Results: In total, 30 of 31 (97%) targeted false lumen intercostal arteries were successfully coiled. Median procedural time was 57 min (interquartile range [IQR] 23-99), median air kerma was 585 mGy (IQR 398-1,644), and median contrast dose was 141 mL (IQR 74-240). After embolization, all patients demonstrated propagation of FLT, with mean false lumen length decreasing by 48% from 13.8 cm to 6.6 cm. There was no mortality associated with this procedure; 2 patients suffered a lumbar drain-related complication; 1 with cerebrospinal fluid leak and 1 with a spinal hematoma that was managed conservatively with no neurological deficit. No other complications occurred.Conclusions: In this review, false lumen intercostal coil embolization was technically feasible and did not result in any cases of SCI. The procedures required acceptable amounts of operative time, fluoroscopic dose, and contrast. All patients experienced propagation of FLT and no longterm procedure-related morbidity was noted. More data will be required to ascertain whether this procedure is effective at halting type R entry flow, preventing future type II entry flow, and promoting aortic remodeling over time.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] Intercostal artery embolization to induce false lumen thrombosis in type B aortic dissection
    Magee, Gregory A.
    Yi, Jeniann A.
    Kuwayama, David P.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2020, 6 (03): : 433 - 437
  • [2] Intercostal Coil Embolization to Induce False Lumen Thrombosis in Chronic Type B Aortic Dissection
    Yi, Jeniann A.
    Magee, Gregory A.
    Eldeiry, Mohammed
    Reese, T. Brett
    Kuwayama, David P.
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E207 - E207
  • [3] Techniques and outcomes of false lumen embolization in chronic type B aortic dissection
    Rohlffs, Fiona
    Spanos, Konstantinos
    Tsilimparis, Nikolaos
    Debus, Eike S.
    Koelbel, Tilo
    JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 59 (06): : 784 - 788
  • [4] Coil Embolization of the False Lumen in Complicated Type B Aortic Dissection
    Hussain, Mohamad A.
    Lindsay, Thomas F.
    Tan, Kong T.
    Moloney, Tony
    ANNALS OF VASCULAR SURGERY, 2015, 29 (01)
  • [5] False lumen embolization for type B dissection complicated by hemoptysis
    López-Benítez, R
    Richter, GM
    Luburic, A
    Böckler, D
    Kauffmann, G
    Hallscheidt, PJ
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2005, 30 (04) : 370 - 375
  • [6] Aortic Diameter, True Lumen, and False Lumen Growth Rates in Chronic Type B Aortic Dissection
    Blount, Kevin J.
    Hagspiel, Klaus D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05) : W222 - W229
  • [7] Initial experience with a modified "candy-plug" technique for false lumen embolization in chronic type B aortic dissection
    Miles, Daniel
    Arbabi, Cassra
    McMackin, Katherine
    Tjaden, Bruce
    Schonefeld, Sally
    Baril, Donald
    Gupta, NavYash
    Gewertz, Bruce
    Azizzadeh, Ali
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2023, 9 (02):
  • [8] The Knickerbocker Technique for Endovascular Exclusion of False Lumen in Chronic Type B Aortic Dissection
    Verzini, Fabio
    Loschi, Diletta
    Simonte, Gioele
    Farchioni, Luca
    Parlani, Gianbattista
    De Rango, Paola
    JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) : 231S - 232S
  • [9] Placement of a branched stent graft into the false lumen of a chronic type B aortic dissection
    Simring, Dominic
    Raja, Jowad
    Morgan-Rowe, Luke
    Hague, Julian
    Harris, Peter L.
    Ivancev, Krassi
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (06) : 1784 - 1787
  • [10] Aortic Arch False Lumen Embolisation in a Residual Chronic Type A Aortic Dissection
    Pellenc, Quentin
    Castier, Yves
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 58 (04) : 600 - 601