Improving image quality using the pause function combination to PROPELLER sequence in brain MRI: a phantom study

被引:0
|
作者
Saotome, Kousaku [1 ,2 ]
Matsumoto, Koji [3 ]
Kato, Yoshiaki [4 ]
Ozaki, Yoshihiro [5 ]
Nagai, Motohiro [4 ]
Hasegawa, Tomoyuki [6 ]
Tsuchiya, Hiroki [7 ]
Yamao, Tensho [1 ]
机构
[1] Fukushima Med Univ, Sch Hlth Sci, Dept Radiol Sci, 10-6 Sakaemachi, Fukushima, Fukushima 9608516, Japan
[2] Univ Tsukuba, Ctr Cybern Res, Tsukuba, Ibaraki 3058577, Japan
[3] Chiba Univ Hosp, Natl Univ Corp, Dept Radiol, Chuo Ku, Chiba, Chiba 2608677, Japan
[4] Kameda Gen Hosp, Med Technol Dept, Diagnost Imaging Room, Kamogawa, Chiba 2968602, Japan
[5] Meiwa Hosp, Dept Radiol, Nishinomiya, Hyogo 6638186, Japan
[6] Hitachi Ltd, Hitachinaka Gen Hosp, Dept Radiol Technol, Hitachinaka, Ibaraki 3120057, Japan
[7] QST Hosp, Natl Inst Quantum Sci & Technol, Dept Med Technol, Radiol Technol Sect, Anagawa, Chiba 2638555, Japan
关键词
PROPELLER; Magnetic resonance imaging; Pause; Radial scan; Phantom; Brain; OVERLAPPING PARALLEL LINES; ENHANCED RECONSTRUCTION PROPELLER; MOTION CORRECTION; BLADE; CONTRAST;
D O I
10.1007/s12194-024-00784-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
While some MRI systems offer a "pause" function, combining it with the PROPELLER method for image quality improvement remains underexplored. This study investigated whether repositioning the head after pausing during PROPELLER imaging enhances image quality. All brain phantom images in this study were obtained using a 3.0 T MRI and acquired using the fast spin-echo T2WI-based PROPELLER with motion correction. By combining the angle of rotational motion of the head phantom and the number of repositioning after a pause, two studies including seven trials were performed. Increasing the rotation angle decreased the image quality; however, pausing the image and repositioning the head phantom to the original angle improved the image quality. A similar result was obtained by repositioning the angle closer to its original angle. Experiments with multiple head movements showed that pausing the scan and repositioning the phantom with each movement improved image quality.
引用
收藏
页码:518 / 526
页数:9
相关论文
共 50 条
  • [41] Estimates of the image quality in accordance with radiation dose for pediatric imaging using deep learning CT: A phantom study
    Jeon, Pil-Hyun
    Kim, Daehong
    Chung, Myung-Ae
    2022 IEEE INTERNATIONAL CONFERENCE ON BIG DATA AND SMART COMPUTING (IEEE BIGCOMP 2022), 2022, : 352 - 356
  • [42] Optimization of image quality and accuracy of low iodine concentration quantification as function of kVp pairs for abdominal imaging using dual-source CT: A phantom study
    Dabli, Djamel
    Frandon, Julien
    Hamard, Aymeric
    Belaouni, Asmaa
    Addala, Takieddine
    Beregi, Jean-Paul
    Greffier, Joel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 285 - 292
  • [43] Editorial for "Image Quality Assessment of Fetal Brain MRI Using Multi-Instance Deep Learning Methods"
    Chen, Luguang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (03) : 830 - 831
  • [44] Longitudinal acquisition repeatability of MRI radiomics features: An ACR MRI phantom study on two MRI scanners using a 3D T1W TSE sequence
    Wong, Oi Lei
    Yuan, JIng
    Zhou, Yihang
    Yu, Siu Ki
    Cheung, Kin Yin
    MEDICAL PHYSICS, 2021, 48 (03) : 1239 - 1249
  • [45] Improving portable low-field MRI image quality through image-to-image translation using paired low- and high-field images
    Islam, Kh Tohidul
    Zhong, Shenjun
    Zakavi, Parisa
    Chen, Zhifeng
    Kavnoudias, Helen
    Farquharson, Shawna
    Durbridge, Gail
    Barth, Markus
    McMahon, Katie L.
    Parizel, Paul M.
    Dwyer, Andrew
    Egan, Gary F.
    Law, Meng
    Chen, Zhaolin
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [46] Improving portable low-field MRI image quality through image-to-image translation using paired low- and high-field images
    Kh Tohidul Islam
    Shenjun Zhong
    Parisa Zakavi
    Zhifeng Chen
    Helen Kavnoudias
    Shawna Farquharson
    Gail Durbridge
    Markus Barth
    Katie L. McMahon
    Paul M. Parizel
    Andrew Dwyer
    Gary F. Egan
    Meng Law
    Zhaolin Chen
    Scientific Reports, 13
  • [47] Study of Image Quality From CT Scanner Multi-Detector by using Americans College of Radiology (ACR) Phantom
    Mulyadin
    Dewang, Syamsir
    Abdullah, Bualkar
    Tahir, Dahlang
    2ND INTERNATIONAL CONFERENCE ON SCIENCE (ICOS), 2018, 979
  • [48] Optimizing image quality using automatic exposure control based on the signal-difference-to-noise ratio: a phantom study
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Hanaoka, Shinsuke
    Matsubara, Kosuke
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (03) : 803 - 810
  • [49] Optimizing image quality using automatic exposure control based on the signal-difference-to-noise ratio: a phantom study
    Hiroki Kawashima
    Katsuhiro Ichikawa
    Shinsuke Hanaoka
    Kosuke Matsubara
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 803 - 810
  • [50] Application of Deconvolution Algorithm of Point Spread Function in Improving Image Quality: An Observer Preference Study on Chest Radiography
    Chae, Kum Ju
    Goo, Jin Mo
    Ahn, Su Yeon
    Yoo, Jin Young
    Yoon, Soon Ho
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (01) : 147 - 152