Improving image quality using the pause function combination to PROPELLER sequence in brain MRI: a phantom study

被引:0
|
作者
Saotome, Kousaku [1 ,2 ]
Matsumoto, Koji [3 ]
Kato, Yoshiaki [4 ]
Ozaki, Yoshihiro [5 ]
Nagai, Motohiro [4 ]
Hasegawa, Tomoyuki [6 ]
Tsuchiya, Hiroki [7 ]
Yamao, Tensho [1 ]
机构
[1] Fukushima Med Univ, Sch Hlth Sci, Dept Radiol Sci, 10-6 Sakaemachi, Fukushima, Fukushima 9608516, Japan
[2] Univ Tsukuba, Ctr Cybern Res, Tsukuba, Ibaraki 3058577, Japan
[3] Chiba Univ Hosp, Natl Univ Corp, Dept Radiol, Chuo Ku, Chiba, Chiba 2608677, Japan
[4] Kameda Gen Hosp, Med Technol Dept, Diagnost Imaging Room, Kamogawa, Chiba 2968602, Japan
[5] Meiwa Hosp, Dept Radiol, Nishinomiya, Hyogo 6638186, Japan
[6] Hitachi Ltd, Hitachinaka Gen Hosp, Dept Radiol Technol, Hitachinaka, Ibaraki 3120057, Japan
[7] QST Hosp, Natl Inst Quantum Sci & Technol, Dept Med Technol, Radiol Technol Sect, Anagawa, Chiba 2638555, Japan
关键词
PROPELLER; Magnetic resonance imaging; Pause; Radial scan; Phantom; Brain; OVERLAPPING PARALLEL LINES; ENHANCED RECONSTRUCTION PROPELLER; MOTION CORRECTION; BLADE; CONTRAST;
D O I
10.1007/s12194-024-00784-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
While some MRI systems offer a "pause" function, combining it with the PROPELLER method for image quality improvement remains underexplored. This study investigated whether repositioning the head after pausing during PROPELLER imaging enhances image quality. All brain phantom images in this study were obtained using a 3.0 T MRI and acquired using the fast spin-echo T2WI-based PROPELLER with motion correction. By combining the angle of rotational motion of the head phantom and the number of repositioning after a pause, two studies including seven trials were performed. Increasing the rotation angle decreased the image quality; however, pausing the image and repositioning the head phantom to the original angle improved the image quality. A similar result was obtained by repositioning the angle closer to its original angle. Experiments with multiple head movements showed that pausing the scan and repositioning the phantom with each movement improved image quality.
引用
收藏
页码:518 / 526
页数:9
相关论文
共 50 条
  • [21] Improving Brain Tumor Segmentation in Multi-sequence MR Images Using Cross-Sequence MR Image Generation
    Zhao, Guojing
    Zhang, Jianpeng
    Xia, Yong
    BRAINLESION: GLIOMA, MULTIPLE SCLEROSIS, STROKE AND TRAUMATIC BRAIN INJURIES (BRAINLES 2019), PT II, 2020, 11993 : 27 - 36
  • [22] Evaluation of Golden-Angle-Sampled Dynamic Contrast-Enhanced MRI Reconstruction Using Objective Image Quality Measures: A Simulated Phantom Study
    Murtha, Nathan
    Mason, Allister
    Bowen, Chris
    Clarke, Sharon
    Rioux, James
    Beyea, Steven
    TOMOGRAPHY, 2020, 6 (04) : 362 - 372
  • [23] Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels
    Love, A.
    Olsson, M-L
    Siemund, R.
    Stalhammar, F.
    Bjorkman-Burtscher, I. M.
    Soderberg, M.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1031):
  • [24] Improving Image Quality of On-Board Cone-Beam CT in Radiation Therapy Using Image Information Provided by Planning Multi-Detector CT: A Phantom Study
    Yang, Ching-Ching
    Chen, Fong-Lin
    Lo, Yeh-Chi
    PLOS ONE, 2016, 11 (06):
  • [25] Quality Assessment of Brain MRI Scans using a Dense Neural Network Model and Image Metrics
    Gupta, Ashish
    Sadri, Amir Reza
    Viswanath, Satish E.
    Tiwari, Pallavi
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [26] Automated image quality evaluation of structural brain MRI using an ensemble of deep learning networks
    Sujit, Sheeba J.
    Coronado, Ivan
    Kamali, Arash
    Narayana, Ponnada A.
    Gabr, Refaat E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (04) : 1260 - 1267
  • [27] Vascular suppression technique in MRI using Gd-DTPA: Improving image quality of MR myelography
    Nasu, K
    Takano, H
    Ito, H
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (03) : 346 - 350
  • [28] Vascular suppression technique in MRI using Gd-DTPA: Improving image quality of MR myelography
    Nasu, Katsuhiro
    Takano, Hideyuki
    Ito, Hisao
    Journal of Computer Assisted Tomography, 23 (03): : 346 - 350
  • [29] Improving Image Quality and Reducing Scan Time for Synthetic MRI of Breast by Using Deep Learning Reconstruction
    Li, Jian
    Wu, Lin-Hua
    Xu, Meng-Ying
    Ren, Jia-Liang
    Li, Zhihao
    Liu, Jin-Rui
    Wang, Ai Jun
    Chen, Bing
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [30] Improving Image Synthesis Quality in Multi-Contrast MRI Using Transfer Learning via Autoencoders
    Selcuk, Saban Yoruc
    Dalmaz, Onat
    Dar, Salman ul Hassan
    Cukur, Tolga
    2022 30TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, SIU, 2022,