Improving portable low-field MRI image quality through image-to-image translation using paired low- and high-field images

被引:12
|
作者
Islam, Kh Tohidul [1 ]
Zhong, Shenjun [1 ,5 ]
Zakavi, Parisa [1 ]
Chen, Zhifeng [1 ,2 ]
Kavnoudias, Helen [3 ,4 ]
Farquharson, Shawna [5 ]
Durbridge, Gail [6 ]
Barth, Markus [7 ,8 ]
McMahon, Katie L. [9 ]
Parizel, Paul M. [10 ,11 ]
Dwyer, Andrew [12 ]
Egan, Gary F. [1 ]
Law, Meng [3 ,4 ]
Chen, Zhaolin [1 ,2 ]
机构
[1] Monash Univ, Monash Biomed Imaging, Melbourne, Vic, Australia
[2] Monash Univ, Fac Informat Technol, Dept Data Sci & AI, Melbourne, Vic, Australia
[3] Monash Univ, Cent Clin Sch, Dept Neurosci, Melbourne, Vic, Australia
[4] Alfred Hosp, Dept Radiol, Melbourne, Vic, Australia
[5] Australian Natl Imaging Facil, Brisbane, Qld, Australia
[6] Queensland Univ Technol, Herston Imaging Res Facil, Brisbane, Qld, Australia
[7] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld, Australia
[8] Univ Queensland, Ctr Adv Imaging, Brisbane, Qld, Australia
[9] Queensland Univ Technol, Sch Clin Sci, Herston Imaging Res Facil, Brisbane, Qld, Australia
[10] Royal Perth Hosp, David Hartley Chair Radiol, Dept Radiol, Perth, WA, Australia
[11] Univ Western Australia, Med Sch, Perth, WA, Australia
[12] South Australian Hlth & Med Res Inst, Adelaide, SA, Australia
关键词
D O I
10.1038/s41598-023-48438-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Low-field portable magnetic resonance imaging (MRI) scanners are more accessible, cost-effective, sustainable with lower carbon emissions than superconducting high-field MRI scanners. However, the images produced have relatively poor image quality, lower signal-to-noise ratio, and limited spatial resolution. This study develops and investigates an image-to-image translation deep learning model, LoHiResGAN, to enhance the quality of low-field (64mT) MRI scans and generate synthetic high-field (3T) MRI scans. We employed a paired dataset comprising T1- and T2-weighted MRI sequences from the 64mT and 3T and compared the performance of the LoHiResGAN model with other state-of-the-art models, including GANs, CycleGAN, U-Net, and cGAN. Our proposed method demonstrates superior performance in terms of image quality metrics, such as normalized root-mean-squared error, structural similarity index measure, peak signal-to-noise ratio, and perception-based image quality evaluator. Additionally, we evaluated the accuracy of brain morphometry measurements for 33 brain regions across the original 3T, 64mT, and synthetic 3T images. The results indicate that the synthetic 3T images created using our proposed LoHiResGAN model significantly improve the image quality of low-field MRI data compared to other methods (GANs, CycleGAN, U-Net, cGAN) and provide more consistent brain morphometry measurements across various brain regions in reference to 3T. Synthetic images generated by our method demonstrated high quality both quantitatively and qualitatively. However, additional research, involving diverse datasets and clinical validation, is necessary to fully understand its applicability for clinical diagnostics, especially in settings where high-field MRI scanners are less accessible.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Improving portable low-field MRI image quality through image-to-image translation using paired low- and high-field images
    Kh Tohidul Islam
    Shenjun Zhong
    Parisa Zakavi
    Zhifeng Chen
    Helen Kavnoudias
    Shawna Farquharson
    Gail Durbridge
    Markus Barth
    Katie L. McMahon
    Paul M. Parizel
    Andrew Dwyer
    Gary F. Egan
    Meng Law
    Zhaolin Chen
    Scientific Reports, 13
  • [2] IMPROVING IMAGE QUALITY IN LOW-FIELD MRI WITH DEEP LEARNING
    Hernandez, Armando Garcia
    Fau, Pierre
    Rapacchi, Stanislas
    Wojak, Julien
    Mailleux, Hugues
    Benkreira, Mohamed
    Adel, Mouloud
    2021 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2021, : 260 - 263
  • [3] Repeatability of image quality in very low-field MRI
    Poojar, Pavan
    Oiye, Ivan Etoku
    Aggarwal, Kunal
    Jimeno, Marina Manso
    Vaughan, John Thomas
    Geethanath, Sairam
    NMR IN BIOMEDICINE, 2024, 37 (10)
  • [4] A Preliminary Study of High-Field MRI Image Enhancement Techniques Applied to Low-Field MR Brain Images
    Ishak, N. F.
    Gangeh, M. J.
    Logeswaran, R.
    4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2): : 482 - 486
  • [5] Deep Learning for Low-Field to High-Field MR: Image Quality Transfer with Probabilistic Decimation Simulator
    Lin, Hongxiang
    Figini, Matteo
    Tanno, Ryutaro
    Blumberg, Stefano B.
    Kaden, Enrico
    Ogbole, Godwin
    Brown, Biobele J.
    D'Arco, Felice
    Carmichael, David W.
    Lagunju, Ikeoluwa
    Cross, Helen J.
    Fernandez-Reyes, Delmiro
    Alexander, Daniel C.
    MACHINE LEARNING FOR MEDICAL IMAGE RECONSTRUCTION, MLMIR 2019, 2019, 11905 : 58 - 70
  • [6] Effects of Encoding Fields of Permanent Magnet Arrays on Image Quality in Low-Field Portable MRI Systems
    Gong, Jia
    Huang, Shao Ying
    Ren, Zhi Hua
    Yu, Wenwei
    IEEE ACCESS, 2019, 7 : 80310 - 80327
  • [7] HIGH-FIELD VERSUS LOW-FIELD IMAGE-CONTRAST WITH RESPECT TO ACUTE AND AGING BLOOD
    SANDERS, JA
    LADYMAN, JA
    ORRISON, WW
    RADIOLOGY, 1995, 197 : 275 - 275
  • [8] Low-field magnetic resonance image enhancement via stochastic image quality transfer
    Lin, Hongxiang
    Figini, Matteo
    D'Arco, Felice
    Ogbole, Godwin
    Tanno, Ryutaro
    Blumberg, Stefano B.
    Ronan, Lisa
    Brown, Biobele J.
    Carmichael, David W.
    Lagunju, Ikeoluwa
    Cross, Judith Helen
    Reyes, Delmiro Fernandez-
    Alexander, Daniel C.
    MEDICAL IMAGE ANALYSIS, 2023, 87 : 1 - 16
  • [9] Low-field MRI can be more sensitive than high-field MRI
    Coffey, Aaron M.
    Truong, Milton L.
    Chekmenev, Eduard Y.
    JOURNAL OF MAGNETIC RESONANCE, 2013, 237 : 169 - 174
  • [10] MRI in rheumatoid arthritis of the hands: Comparison of high-field and low-field MRI
    Taouli, BA
    Zaim, S
    Lynch, JA
    Peterfy, CG
    Stork, A
    Fan, B
    RADIOLOGY, 2001, 221 : 523 - 523