Manual and semi-automated computed tomography volumetry significantly overestimates the right liver lobe graft weight: a single-center study with adult living liver donors

被引:0
|
作者
Celik, Hakki [1 ]
Odaman, Hueseyin
Altay, Canan [1 ]
Unek, Tarkan [2 ]
Ozbilgin, Muecahit
Egeli, Tufan [2 ]
Agalar, Cihan [2 ]
Astarcioglu, Ibrahim Kemal [2 ]
Barlik, Funda [1 ]
机构
[1] Dokuz Eylul Univ, Fac Med, Dept Radiol, Izmir, Turkiye
[2] Dokuz Eylul Univ, Fac Med, Dept Gen Surg, Izmir, Turkiye
来源
关键词
Liver; living donor liver transplantation; manual CT volumetry; semi-automated CT volumetry; transplantation; TRANSPLANTATION;
D O I
10.4274/dir.2023.221903
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE Preoperative evaluation of donor liver volume is indispensable in living donor liver transplantation to ensure sufficient residual liver and graft -to -recipient weight ratio. This study aims to evaluate the accuracy of two computed tomography (CT) volumetry programs, an interactive manual and a semi -automated one, in the preoperative estimation of the right lobe graft weight. METHODS One hundred and nine right liver lobe living donors between January 2008 and January 2020 were enrolled in this retrospective study. Two radiologists measured the liver graft volumes independently using manual and semi -automated CT volumetry, and the interaction time was recorded. Actual graft weight (AGW) measured intraoperatively served as the reference standard. The paired samples t -test was used to compare the estimated graft weight (EGW) and the AGW. Inter -user and inter -method agreements were assessed with Bland-Altman plots. RESULTS Both manual and semi -automated CT volumetry significantly overestimated the graft weight (EGW manual: 893 +/- 155 mL vs. AGW manual: 787 +/- 128 g, P < 0.001, EGW semi -automated: 879 +/- 143 mL vs. AGW semi -automated, P < 0.001). The junior radiologist measured higher volumes than the senior radiologist with either method (P < 0.001). The Bland-Altman analysis revealed mean difference and standard deviation for inter -method agreement of 7 +/- 48 cc for the senior radiologist, and 34 +/- 54 cc for the junior radiologist. The mean difference and standard deviation for inter -method agreement was 63 +/- 59 cc in manual volumetry and 22 +/- 38 cc in semi -automated volumetry. The mean interaction time was 27.3 +/- 14.2 min for manual volumetry and 6.8 +/- 1.4 min for semi -automated volumetry (P < 0.001). CONCLUSION Both manual and semi -automated CT volumetry significantly overestimated the right liver graft weight, while semi -automated volumetry significantly reduced the interaction time.
引用
收藏
页码:3 / 8
页数:6
相关论文
共 50 条
  • [21] POSTOPERATIVE OUTCOME OF DONORS IN RIGHT LOBE LIVING DONOR LIVER TRANSPLANTATION IN ADULTS - A SINGLE CENTER EXPERIENCE
    Baerthel, E.
    Ispikoudis, N.
    Goetz, M.
    Bauschke, A.
    Voigt, R.
    Heise, M.
    Settmacher, U.
    TRANSPLANT INTERNATIONAL, 2011, 24 : 42 - 42
  • [22] Guideline proposal for graft type selection with right lobe graft by the novel approach to volumetry in adult living-donor liver transplantation.
    Fujimoto, Y
    Bourquain, H
    Kasahara, M
    Ito, T
    Ogura, Y
    Ogawa, K
    Egawa, H
    Takada, Y
    Peitgen, HO
    Tanaka, K
    AMERICAN JOURNAL OF TRANSPLANTATION, 2004, 4 : 169 - 169
  • [23] Respiratory Complications Among Living Liver Donors: A Single-Center Retrospective Observational Study
    Shorbagy, Mohammed S.
    Saleh, Mohammed
    Elbeialy, Marwa A. K.
    Elsaid, Kamal
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2020, 18 (04) : 474 - 480
  • [24] Preoperative Estimation of the Liver Graft Weight in Adult Right Lobe Living Donor Liver Transplantation Using Maximal Portal Vein Diameters
    Wang, Frank
    Pan, Kuang-Tse
    Chu, Sung-Yu
    Chan, Kun-Ming
    Chou, Hong-Shiue
    Wu, Ting-Jung
    Lee, Wei-Chen
    LIVER TRANSPLANTATION, 2011, 17 (04) : 373 - 380
  • [25] Evaluation of Renal Arteries of 286 Living Donors by Multidetector Computed Tomography Angiography: A Single-Center Study
    Cira, Kamil
    Demirtas, Hakan
    Durmaz, Mehmet Sedat
    Ceken, Kagan
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2015, 13 (06) : 581 - 587
  • [26] Venous outflow reconstruction using a polytetrafluoroethylene (PTFE) graft in right lobe living donor liver transplantation: A single center study
    Singhal, Ashish
    Makki, Kausar
    Chorasiya, Vishal
    Khan, Arif Ali
    Mohamed, Qaleem
    Ahmad, Furquan
    Srivastava, Ajitabh
    Vij, Vivek
    SURGERY, 2021, 169 (06) : 1500 - 1509
  • [27] Urgent adult-to-adult right lobe living donor liver transplantation for acute liver failure; A single center experience from Turkey
    Karasu, Zeki
    Akyildiz, Murat
    Zeytunlu, Murat
    Noyan, Aysin
    Yuzer, Yidiray
    Tokat, Yaman
    Kilic, Murat
    HEPATO-GASTROENTEROLOGY, 2007, 54 (75) : 810 - 813
  • [28] Accuracy of Estimation of Graft Size for Living-Related Liver Transplantation: First Results of a Semi-Automated Interactive Software for CT-Volumetry
    Mokry, Theresa
    Bellemann, Nadine
    Mueller, Dirk
    Bermejo, Justo Lorenzo
    Klauss, Miriam
    Stampfl, Ulrike
    Radeleff, Boris
    Schemmer, Peter
    Kauczor, Hans-Ulrich
    Sommer, Christof-Matthias
    PLOS ONE, 2014, 9 (10):
  • [29] Adult-to-adult right lobe graft living donor liver transplantation for acute-on-chronic liver failure: a single-centre retrospective study in Vietnam
    Vu, Quang V.
    Le, Thanh V.
    Le, Hieu T.
    Nguyen, Anh H. N.
    Nguyen, Duy T.
    ANNALS OF MEDICINE AND SURGERY, 2024, 86 (03): : 1261 - 1267
  • [30] Adult-to-adult living donor liver transplantation using right-lobe grafts: Results and lessons learned from a single-center experience
    Bak, T
    Wachs, M
    Trotter, J
    Everson, G
    Trouillot, T
    Kugelmas, M
    Steinberg, T
    Kam, I
    LIVER TRANSPLANTATION, 2001, 7 (08) : 680 - 686