Mass-independent fractionation during Mo isotope measurement by MC-ICP-MS: implications for application of the double spike technique

被引:3
|
作者
Zhao, Yan [1 ]
Yang, Wubin [2 ,3 ]
Leng, Chengbiao [1 ]
机构
[1] East China Univ Technol, State Key Lab Nucl Resources & Environm, Nanchang 330013, Peoples R China
[2] Chinese Acad Sci, Guangzhou Inst Geochem, Key Lab Mineral & Metallogeny, Guangdong Prov Key Lab Mineral Phys & Mat, Guangzhou 510640, Peoples R China
[3] CAS Ctr Excellence Deep Earth Sci, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
GEOLOGICAL SAMPLES; ERROR PROPAGATION; AMOUNT RATIOS; MOLYBDENUM; EQUATIONS; PRECISE;
D O I
10.1039/d2ja00427e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents our new observation on mass-independent fractionation (MIF) during Mo isotope measurement by MC-ICP-MS and investigates its implication for the application of the double spike (DS) technique. A mixture of NIST SRM 3134 Mo solution with a calibrated Mo-97-Mo-100 DS (1 : 1) was prepared for measurements over similar to 15 h. The Mo isotopic data in this study show a good linear relationship in the scatter plots of ln(Mo-97/95) vs. ln(Mo-98/95), ln(Mo-97/95) vs. ln(Mo-100/95), and ln(Mo-98/95) vs. ln(Mo-100/95). Considering measurement errors on both vertical and horizontal axes, York linear regression was applied to linear fit. The slopes derived from the York linear regression are 1.33 +/- 0.12 (2SE), 2.30 +/- 0.20 (2SE), and 1.73 +/- 0.14 (2SE), respectively. Given the error, the slopes are not exactly consistent with their theoretically expected values (1.49, 2.46, and 1.64) based on the assumption of mass-dependent fractionation (MDF). This study, for the first time, identifies MIF during Mo isotope measurement by MC-ICP-MS. DS calculation using theoretical mass fractionation factors shows that the analyzed NIST SRM 3134 Mo solution yielded delta Mo-98/95 values of 0.00 +/- 0.04 parts per thousand (2SD, n = 17) relative to the originally calibrated NIST SRM 3134 Mo. However, using experimental mass fractionation factors calculated from the slopes of line relationships, there is a deviation of about 0.46 parts per thousand for delta Mo-98/95. The results indicate that the calibrated isotope ratios of the standard and DS could not be the true values but approximate values for better matching with the MDF-based equations. After DS calculation using experimental and theoretical mass fractionation factors, respectively, an additional standard-sample bracketing (SSB) method was conducted. Both calculations gave identical and accurate delta Mo-98/95 values (0.00 +/- 0.06 parts per thousand), indicating that the SSB method is able to correct deviation from MIF during DS calculation. Accordingly, we proposed that an additional SSB method is recommended to acquire accurate isotope ratios during the application of the DS technique. This study highlights that researchers should pay attention to the possible existence of instrument-related MIF during isotope measurement.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 50 条
  • [31] An improved method of Cr purification for high precision measurement of Cr isotopes by double spike MC-ICP-MS
    Zhu, Jian-Ming
    Wu, Guangliang
    Wang, Xiangli
    Han, Guilin
    Zhang, Lixin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (05) : 809 - 821
  • [32] High-Sensitivity Measurement of Cr Isotopes by Double Spike MC-ICP-MS at the 10 ng Level
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    Johnson, Thomas M.
    Han, Guilin
    ANALYTICAL CHEMISTRY, 2020, 92 (01) : 1463 - 1469
  • [33] Ultra-precise titanium stable isotope measurements by double-spike high resolution MC-ICP-MS
    Millet, Marc-Alban
    Dauphas, Nicolas
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (08) : 1444 - 1458
  • [34] High-Precision Sn Isotopic Measurement in Geological Materials by Double-Spike MC-ICP-MS
    Song, Wenrui
    Zhu, Chuanwei
    Wen, Hanjie
    Zhang, Yuxu
    Liu, Zerui
    Zhou, Meifu
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024,
  • [35] Stable W Isotope Measurements of Geological Reference Materials and Tungsten Ore Minerals by Double Spike MC-ICP-MS
    Zhang, Tianli
    Liu, Jia
    Zhang, Qun
    Zhang, Yingnan
    Qin, Liping
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 47 (01) : 169 - 183
  • [36] Mass-dependent isotopic fractionation of Sr in geochemical samples by MC-ICP-MS
    Ohno, Takeshi
    Wakabayashi, Takahiro
    Hirata, Takafumi
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A701 - A701
  • [37] The influence of the double spike proportion effect on stable isotope (Zn, Mo, Cd, and Sn) measurements by multicollector-inductively coupled plasma-mass spectrometry (MC-ICP-MS)
    Zhang, Le
    Li, Jie
    Xu, Yi-Gang
    Ren, Zhong-Yuan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (04) : 555 - 562
  • [38] Stable Cr isotope ratio measurements using a double-spike method and high-resolution MC-ICP-MS
    von Blanckenburg, F
    Schoenberg, R
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A867 - A867
  • [39] Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS
    Guo, Chao
    Li, Tao
    Li, Gaojun
    Chen, Tianyu
    Li, Le
    Zhao, Liang
    Ji, Junfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2470 - 2479
  • [40] A novel chemical purification method for accurate Sn isotope measurement by MC-ICP-MS
    Qu, Qinyuan
    Liu, Wengang
    Zheng, Wang
    Chetelat, Benjamin
    Liu, Qingchuan
    Chen, Jiubin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (09) : 2258 - 2269