Mass-independent fractionation during Mo isotope measurement by MC-ICP-MS: implications for application of the double spike technique

被引:3
|
作者
Zhao, Yan [1 ]
Yang, Wubin [2 ,3 ]
Leng, Chengbiao [1 ]
机构
[1] East China Univ Technol, State Key Lab Nucl Resources & Environm, Nanchang 330013, Peoples R China
[2] Chinese Acad Sci, Guangzhou Inst Geochem, Key Lab Mineral & Metallogeny, Guangdong Prov Key Lab Mineral Phys & Mat, Guangzhou 510640, Peoples R China
[3] CAS Ctr Excellence Deep Earth Sci, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
GEOLOGICAL SAMPLES; ERROR PROPAGATION; AMOUNT RATIOS; MOLYBDENUM; EQUATIONS; PRECISE;
D O I
10.1039/d2ja00427e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents our new observation on mass-independent fractionation (MIF) during Mo isotope measurement by MC-ICP-MS and investigates its implication for the application of the double spike (DS) technique. A mixture of NIST SRM 3134 Mo solution with a calibrated Mo-97-Mo-100 DS (1 : 1) was prepared for measurements over similar to 15 h. The Mo isotopic data in this study show a good linear relationship in the scatter plots of ln(Mo-97/95) vs. ln(Mo-98/95), ln(Mo-97/95) vs. ln(Mo-100/95), and ln(Mo-98/95) vs. ln(Mo-100/95). Considering measurement errors on both vertical and horizontal axes, York linear regression was applied to linear fit. The slopes derived from the York linear regression are 1.33 +/- 0.12 (2SE), 2.30 +/- 0.20 (2SE), and 1.73 +/- 0.14 (2SE), respectively. Given the error, the slopes are not exactly consistent with their theoretically expected values (1.49, 2.46, and 1.64) based on the assumption of mass-dependent fractionation (MDF). This study, for the first time, identifies MIF during Mo isotope measurement by MC-ICP-MS. DS calculation using theoretical mass fractionation factors shows that the analyzed NIST SRM 3134 Mo solution yielded delta Mo-98/95 values of 0.00 +/- 0.04 parts per thousand (2SD, n = 17) relative to the originally calibrated NIST SRM 3134 Mo. However, using experimental mass fractionation factors calculated from the slopes of line relationships, there is a deviation of about 0.46 parts per thousand for delta Mo-98/95. The results indicate that the calibrated isotope ratios of the standard and DS could not be the true values but approximate values for better matching with the MDF-based equations. After DS calculation using experimental and theoretical mass fractionation factors, respectively, an additional standard-sample bracketing (SSB) method was conducted. Both calculations gave identical and accurate delta Mo-98/95 values (0.00 +/- 0.06 parts per thousand), indicating that the SSB method is able to correct deviation from MIF during DS calculation. Accordingly, we proposed that an additional SSB method is recommended to acquire accurate isotope ratios during the application of the DS technique. This study highlights that researchers should pay attention to the possible existence of instrument-related MIF during isotope measurement.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 50 条
  • [41] A common matrix method for precise and accurate isotope ratio measurement by MC-ICP-MS
    Barling, Jane
    Weis, Dominique
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A56 - A56
  • [42] High-Precision Cd Isotope Measurements of Soil and Rock Reference Materials by MC-ICP-MS with Double Spike Correction
    Liu, Meng-Shu
    Zhang, Qun
    Zhang, Yingnan
    Zhang, Zhaofeng
    Huang, Fang
    Yu, Hui-Min
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2020, 44 (01) : 169 - 182
  • [43] Sulfur isotope measurement of sulfate and sulfide by high-resolution MC-ICP-MS
    Craddock, Paul R.
    Rouxel, Olivier J.
    Ball, Lary A.
    Bach, Wolfgang
    CHEMICAL GEOLOGY, 2008, 253 (3-4) : 102 - 113
  • [44] Measurement of sulfur isotope ratios in trace amounts of dissolved sulfate by MC-ICP-MS
    Moon, Jonghan
    Joo, Young Ji
    Kang, Jung Ok
    Sim, Min Sub
    JOURNAL OF THE GEOLOGICAL SOCIETY OF KOREA, 2021, 57 (01) : 99 - 108
  • [45] Development of a Direct Procedure for the Measurement of Sulfur Isotope Variability in Beers by MC-ICP-MS
    Giner Martinez-Sierra, J.
    Santamaria-Fernandez, R.
    Hearn, R.
    Marchante Gayon, J. M.
    Garcia Alonso, J. I.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (07) : 4043 - 4050
  • [46] Precise isotope ratio measurements by MC-ICP-MS and application of the isotope dilution technique for the determination of germanium in the Gallium Neutrino Observatory
    Wallenius, M.
    Mayer, K.
    Millet, S.
    Nicholl, A.
    Henrich, E.
    Balata, M.
    Nisi, S.
    Luetzenkirchen, K.
    RADIOCHIMICA ACTA, 2008, 96 (08) : 449 - 453
  • [47] Observations of Large Mass-Independent Fractionation Occurring in MC-ICPMS: Implications for Determination of Accurate Isotope Amount Ratios
    Yang, Lu
    Mester, Zoltan
    Zhou, Lian
    Gao, Shan
    Sturgeon, Ralph E.
    Meija, Juris
    ANALYTICAL CHEMISTRY, 2011, 83 (23) : 8999 - 9004
  • [48] Application of strontium isotope abundance ratios measured by MC-ICP-MS for food authentication
    Fortunato, G
    Mumic, K
    Wunderli, S
    Pillonel, L
    Bosset, JO
    Gremaud, G
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (02) : 227 - 234
  • [49] Lead isotope measurement using a multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Choi, Hye-Bin
    Ryu, Jong-Sik
    Park, Sanghee
    Lee, Jeonghoon
    JOURNAL OF THE GEOLOGICAL SOCIETY OF KOREA, 2018, 54 (03) : 311 - 318
  • [50] Germanium isotope measurements of high-temperature geothermal fluids using double-spike hydride generation MC-ICP-MS
    Siebert, Christopher
    Ross, Andy
    McManus, James
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (15) : 3986 - 3995