Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis

被引:7
|
作者
Zhong, Zhou [1 ]
Lan, Xuejun [2 ]
Xiang, Zhou [1 ]
Duan, Xin [1 ,3 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Orthoped Surg, 37 Guoxue Lane, Chengdu 610041, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Hlth Management Ctr, Gen Practice Ctr, 37 Guoxue Lane, Chengdu 610041, Peoples R China
[3] Sichuan Fifth Peoples Hosp, Dept Orthoped Surg, Chengdu 610000, Peoples R China
基金
中国国家自然科学基金;
关键词
Femoral neck fractures; Cannulated compression screws; Femoral neck system; Biomechanics; Finite element analysis; DYNAMIC HIP SCREW; INTERNAL-FIXATION; MANAGEMENT; POSITION; ANGLE; RISK;
D O I
10.1016/j.clinbiomech.2023.106060
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: High shear force is a major factor detrimental to the healing of vertical femoral neck fractures. In addition to firm fixation, reduction quality is crucial for postoperative stability. The present study aimed to compare the biomechanical stability of the newly invented femoral neck system and three inverted-triangle cannulated compression screws treatments for non-anatomical reduction of Pauwels type-III femoral neck fractures. Methods: A total of 18 non-anatomical reduction Pauwels type-III femoral neck fracture finite element models were fabricated and fixed using three inverted-triangle cannulated compression screws or the femoral neck system. A 1950-N force was applied to the femoral head to simulate the physiological load during a single-leg stance. Parameters of the maximum total deformation, the interfragmentary gap, and the maximum von Mises stress of the implants and the proximal femur were analyzed. Findings: The results of the maximum total deformation, interfragmentary gap, and maximum von Mises stress of the implants in the negative-negative buttress model fixed by the femoral neck system were the largest among all groups (3.58 mm, 0.252 mm, and 729.68 MPa, respectively). In contrast, the anatomical-anatomical reduction model fixed by three inverted-triangle cannulated compression screws demonstrated the minimum total deformation, interfragmentary gap, and minimum von Mises stress of implants (1.107 mm, 0.09 mm, and 189.83 MPa, respectively). Interpretation: Anatomical reduction or positive buttress in femoral neck fractures should be recommended during fracture reduction. The femoral neck system showed weaker biomechanical stability than three inverted-triangle cannulated compression screws in treating Pauwels type-III femoral neck fractures.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Medial femoral plate with cannulated screw for Pauwels type III femoral neck fracture: A meta-analysis
    Su, Zhengbing
    Liang, Linlin
    Hao, Yong
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2021, 34 (02) : 169 - 177
  • [42] Cannulated screws fixation as an alternative treatment of femoral neck osteoporotic fractures
    Ciesielczyk, B
    Tuchocka-Piotrowska, A
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 516 - +
  • [43] Is Femoral Neck System a Valid Alternative for the Treatment of Displaced Femoral Neck Fractures in Adolescents? A Comparative Study of Femoral Neck System versus Cannulated Compression Screw
    Lu, Yunan
    Canavese, Federico
    Nan, Guoxin
    Lin, Ran
    Huang, Yuling
    Pan, Nuoqi
    Chen, Shunyou
    MEDICINA-LITHUANIA, 2022, 58 (08):
  • [44] Comparative results of percutaneous cannulated screws, dynamic compression type plate and screw for the treatment of femoral neck fractures
    Kaplan, Tolga
    Akesen, Burak
    Demirag, Burak
    Bilgen, Sadik
    Durak, Kemal
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2012, 18 (01): : 65 - 70
  • [45] Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture
    Lin Tianye
    Yang Peng
    Xu Jingli
    Wei QiuShi
    Zhou GuangQuan
    He Wei
    Zhang Qingwen
    BIOMEDICINE & PHARMACOTHERAPY, 2019, 112
  • [46] Biomechanical comparison of Gofried positive support reduction of Pauwels type III femoral neck fractures: A finite elements analysis
    Ding, Ming
    Su, Zhihao
    Wang, Daoyu
    Mo, Lan
    Mei, Jiong
    Sun, Wanju
    Li, Shuang
    Ni, Ming
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (12):
  • [47] The effect of anteromedial support plate with three cannulated screws in the treatment of Pauwels type III femoral neck fracture in young adults
    Shanghui Lin
    Jinmei Li
    Renkai Wang
    Yongliang Ou
    Zhenyu Jia
    Ying Zhang
    Hong Xia
    Baofeng Li
    Bei Chen
    European Journal of Trauma and Emergency Surgery, 2022, 48 : 4011 - 4017
  • [48] The effect of anteromedial support plate with three cannulated screws in the treatment of Pauwels type III femoral neck fracture in young adults
    Lin, Shanghui
    Li, Jinmei
    Wang, Renkai
    Ou, Yongliang
    Jia, Zhenyu
    Zhang, Ying
    Xia, Hong
    Li, Baofeng
    Chen, Bei
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (05) : 4011 - 4017
  • [49] Biomechanical Evaluation of Cannulated Screw Optimization for Stabilization of Pauwels Type Femoral Neck Fractures
    Verim, Ozgur
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [50] Treatment of Delbet II/III Pediatric Femoral Neck Fractures With Proximal Femoral Locking Plate Versus Cannulated Screws
    Haider, Shamrez
    Harris, Timothy J.
    Turner, Alexander C.
    Podeszwa, David A.
    Hartman, Courtney A.
    Morris, William Z.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2024, 44 (04) : 213 - 220