Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis

被引:7
|
作者
Zhong, Zhou [1 ]
Lan, Xuejun [2 ]
Xiang, Zhou [1 ]
Duan, Xin [1 ,3 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Orthoped Surg, 37 Guoxue Lane, Chengdu 610041, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Hlth Management Ctr, Gen Practice Ctr, 37 Guoxue Lane, Chengdu 610041, Peoples R China
[3] Sichuan Fifth Peoples Hosp, Dept Orthoped Surg, Chengdu 610000, Peoples R China
基金
中国国家自然科学基金;
关键词
Femoral neck fractures; Cannulated compression screws; Femoral neck system; Biomechanics; Finite element analysis; DYNAMIC HIP SCREW; INTERNAL-FIXATION; MANAGEMENT; POSITION; ANGLE; RISK;
D O I
10.1016/j.clinbiomech.2023.106060
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: High shear force is a major factor detrimental to the healing of vertical femoral neck fractures. In addition to firm fixation, reduction quality is crucial for postoperative stability. The present study aimed to compare the biomechanical stability of the newly invented femoral neck system and three inverted-triangle cannulated compression screws treatments for non-anatomical reduction of Pauwels type-III femoral neck fractures. Methods: A total of 18 non-anatomical reduction Pauwels type-III femoral neck fracture finite element models were fabricated and fixed using three inverted-triangle cannulated compression screws or the femoral neck system. A 1950-N force was applied to the femoral head to simulate the physiological load during a single-leg stance. Parameters of the maximum total deformation, the interfragmentary gap, and the maximum von Mises stress of the implants and the proximal femur were analyzed. Findings: The results of the maximum total deformation, interfragmentary gap, and maximum von Mises stress of the implants in the negative-negative buttress model fixed by the femoral neck system were the largest among all groups (3.58 mm, 0.252 mm, and 729.68 MPa, respectively). In contrast, the anatomical-anatomical reduction model fixed by three inverted-triangle cannulated compression screws demonstrated the minimum total deformation, interfragmentary gap, and minimum von Mises stress of implants (1.107 mm, 0.09 mm, and 189.83 MPa, respectively). Interpretation: Anatomical reduction or positive buttress in femoral neck fractures should be recommended during fracture reduction. The femoral neck system showed weaker biomechanical stability than three inverted-triangle cannulated compression screws in treating Pauwels type-III femoral neck fractures.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture
    Teng, Yanbin
    Zhang, Yan
    Guo, Chaowei
    MEDICINE, 2022, 101 (28) : E29450
  • [2] Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis
    Fan, Xiao
    Zhou, Yimin
    Dai, Shiyou
    Lao, Kecheng
    Zhang, Qiliang
    Yu, Tengbo
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [3] Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis
    Xiao Fan
    Yimin Zhou
    Shiyou Dai
    Kecheng Lao
    Qiliang Zhang
    Tengbo Yu
    BMC Musculoskeletal Disorders, 25
  • [4] Femoral Neck System vs. four cannulated screws in the treatment of Pauwels III femoral neck fracture
    Lin, Hongkuan
    Lai, Caosheng
    Zhou, Zhiping
    Wang, Chaoqiang
    Yu, Xinlin
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (06) : 1373 - 1378
  • [5] Finite element analysis of the Femoral neck system for different placement positions in the fixation of Pauwels type III femoral neck fractures
    Zhu, Yongjia
    Wu, Shuai
    Yan, Jiapeng
    Wang, Wenhong
    Huang, Xiao
    Zhang, Hongfei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2025, 56 (04):
  • [6] Biomechanical comparison of femoral neck system and cannulated screws coupled with medial plate for treating Pauwels III femoral neck fractures
    Nan, Chong
    Li, Yanjun
    Liu, Yuxiu
    Ma, Liang
    Ma, Zhanbei
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (04) : 1161 - 1170
  • [7] Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws
    Stoffel, Karl
    Zderic, Ivan
    Gras, Florian
    Sommer, Christoph
    Eberli, Ursula
    Mueller, David
    Oswald, Martin
    Gueorguiev, Boyko
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (03) : 131 - 137
  • [8] Finite element analysis of a new plate for Pauwels type III femoral neck fractures
    Wang, Gang
    Tang, Yong
    Wu, Xuhua
    Yang, Huilin
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (02)
  • [9] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Huang, Shaolong
    Zhang, Yazhong
    Zhang, Xu
    Zhou, Chengqiang
    Li, Wenbo
    Wang, Yunqing
    Wang, Bin
    Zhu, Ziqiang
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [10] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Shaolong Huang
    Yazhong Zhang
    Xu Zhang
    Chengqiang Zhou
    Wenbo Li
    Yunqing Wang
    Bin Wang
    Ziqiang Zhu
    BioMedical Engineering OnLine, 22