Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis

被引:7
|
作者
Zhong, Zhou [1 ]
Lan, Xuejun [2 ]
Xiang, Zhou [1 ]
Duan, Xin [1 ,3 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Orthoped Surg, 37 Guoxue Lane, Chengdu 610041, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Hlth Management Ctr, Gen Practice Ctr, 37 Guoxue Lane, Chengdu 610041, Peoples R China
[3] Sichuan Fifth Peoples Hosp, Dept Orthoped Surg, Chengdu 610000, Peoples R China
基金
中国国家自然科学基金;
关键词
Femoral neck fractures; Cannulated compression screws; Femoral neck system; Biomechanics; Finite element analysis; DYNAMIC HIP SCREW; INTERNAL-FIXATION; MANAGEMENT; POSITION; ANGLE; RISK;
D O I
10.1016/j.clinbiomech.2023.106060
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: High shear force is a major factor detrimental to the healing of vertical femoral neck fractures. In addition to firm fixation, reduction quality is crucial for postoperative stability. The present study aimed to compare the biomechanical stability of the newly invented femoral neck system and three inverted-triangle cannulated compression screws treatments for non-anatomical reduction of Pauwels type-III femoral neck fractures. Methods: A total of 18 non-anatomical reduction Pauwels type-III femoral neck fracture finite element models were fabricated and fixed using three inverted-triangle cannulated compression screws or the femoral neck system. A 1950-N force was applied to the femoral head to simulate the physiological load during a single-leg stance. Parameters of the maximum total deformation, the interfragmentary gap, and the maximum von Mises stress of the implants and the proximal femur were analyzed. Findings: The results of the maximum total deformation, interfragmentary gap, and maximum von Mises stress of the implants in the negative-negative buttress model fixed by the femoral neck system were the largest among all groups (3.58 mm, 0.252 mm, and 729.68 MPa, respectively). In contrast, the anatomical-anatomical reduction model fixed by three inverted-triangle cannulated compression screws demonstrated the minimum total deformation, interfragmentary gap, and minimum von Mises stress of implants (1.107 mm, 0.09 mm, and 189.83 MPa, respectively). Interpretation: Anatomical reduction or positive buttress in femoral neck fractures should be recommended during fracture reduction. The femoral neck system showed weaker biomechanical stability than three inverted-triangle cannulated compression screws in treating Pauwels type-III femoral neck fractures.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Modified F configuration in the treatment of Pauwels type III femoral neck fracture: a finite element analysis
    Lin, Shiyuan
    Shang, Jie
    Xing, Baizhou
    Wu, Biao
    Peng, Rong
    Wang, Gang
    Lu, Hua-Ding
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [32] Modified F configuration in the treatment of Pauwels type III femoral neck fracture: a finite element analysis
    Shiyuan Lin
    Jie Shang
    Baizhou Xing
    Biao Wu
    Rong Peng
    Gang Wang
    Hua-Ding Lu
    BMC Musculoskeletal Disorders, 22
  • [33] Femoral neck system versus multiple cannulated screws for the fixation of Pauwels classification type II femoral neck fractures in older female patients with low bone mass
    Yeoh, Soon-Chin
    Wu, Wen-Tien
    Peng, Cheng-Huan
    Yao, Ting-Kuo
    Chang, Chia-Ming
    Liu, Kuan-Lin
    Yu, Tzai-Chiu
    Chen, Ing-Ho
    Wang, Jen-Hung
    Yeh, Kuang-Ting
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [34] Finite Element Analysis of Six Internal Fixations in the Treatment of Pauwels Type III Femoral Neck Fracture
    Sun, Xiang
    Han, Zhe
    Cao, Dongdong
    Han, Chao
    Xie, Mengqi
    Zeng, Xiantie
    Dong, Qiang
    ORTHOPAEDIC SURGERY, 2024, 16 (07) : 1695 - 1709
  • [35] Femoral neck system versus multiple cannulated screws for the fixation of Pauwels classification type II femoral neck fractures in older female patients with low bone mass
    Soon-Chin Yeoh
    Wen-Tien Wu
    Cheng-Huan Peng
    Ting-Kuo Yao
    Chia-Ming Chang
    Kuan-Lin Liu
    Tzai-Chiu Yu
    Ing-Ho Chen
    Jen-Hung Wang
    Kuang-Ting Yeh
    BMC Musculoskeletal Disorders, 25
  • [36] Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures
    Ma, Ji
    Zhao, Ziying
    Zhi, Xiaodong
    Wang, Hao
    Wang, Wei
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [37] Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures
    Ji Ma
    Ziying Zhao
    Xiaodong Zhi
    Hao Wang
    Wei Wang
    BMC Musculoskeletal Disorders, 23
  • [38] A model to evaluate Pauwels type III femoral neck fractures
    Magone, Kevin M.
    Owen, Jonas K.
    Kemker, Bernard P.
    Bloom, Oliver
    Martin, Sidney
    Atkinson, Patrick
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (03) : 310 - 317
  • [39] Mechanical effects of sagittal variations on Pauwels type III femoral neck fractures treated with Femoral Neck System(FNS)
    Chong Nan
    Liang Ma
    Yuechuang Liang
    Yanjun Li
    Zhanbei Ma
    BMC Musculoskeletal Disorders, 23
  • [40] Mechanical effects of sagittal variations on Pauwels type III femoral neck fractures treated with Femoral Neck System(FNS)
    Nan, Chong
    Ma, Liang
    Liang, Yuechuang
    Li, Yanjun
    Ma, Zhanbei
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)