Treatment of Acetabular Bone Defect in Revision of Total Hip Arthroplasty Using 3D Printed Tantalum Acetabular Augment

被引:12
|
作者
Ying, Jiawei [1 ]
Cheng, Liangliang [1 ]
Li, Junlei [1 ]
Wu, Bin [1 ]
Qiu, Xing [1 ]
Zhang, Tianwei [1 ]
Wang, Feng [1 ]
Liu, Baoyi [1 ]
Yang, Lei [1 ]
Pokharel, Durga Bhakta [1 ]
Xie, Hui [1 ]
Wang, Fuyang [1 ]
Liu, Yuchen [1 ]
Xu, Minghao [1 ]
Yu, Haiyu [1 ]
Zhao, Dewei [1 ]
机构
[1] Dalian Univ, Dept Orthopaed, Zhongshan Hosp, 6 Jiefang St, Dalian 116001, Liaoning, Peoples R China
关键词
3D printed; Acetabular bone defect; Customized augment; Revision of total hip arthroplasty; Tantalum; TRABECULAR METAL AUGMENTS; POROUS TANTALUM; RECONSTRUCTION;
D O I
10.1111/os.13691
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveThe treatment of acetabular defects is one of the most difficult challenges of revision of total hip arthroplasty (RTHA), and tantalum is regarded as a promising bone substitute material. This study aims to investigate the effectiveness of 3D printed acetabular augment used in RTHA for the treatment of acetabular bone defect. MethodsA retrospective analysis of the clinical data of seven patients who had undergone RTHA was carried out using 3D printed acetabular augment from January 2017 to December 2018. The CT data of the patients were exported to Mimics 21.0 software (Materialise, Leuven, Belgium), and the acetabular bone defect augment were designed, printed and then implanted during operation. The postoperative Harris score, visual analogue scale (VAS) score and prosthesis position were observed to evaluate the clinical outcome. A I-test was used for preoperative and postoperative comparison of the paired-design dataset. ResultsA firm attachment of the bone augment to the acetabulum during operation without any complications was found during the follow-up time 2.8-4.3 years. The VAS score of all patients was found 6.9 +/- 1.4 before operation and was 0.7 +/- 0.7 at the last follow-up (P <= 0.001), and the Harris hip scores, were 31.9 +/- 10.3 and 73.3 +/- 12.8 before operation, and at the last follow-up (P <= 0.001), respectively. Moreover, no loosening sign between the bone defect augment and the acetabulum was observed during the entire implantation period. Conclusion3D printed acetabular augment is effective in reconstructing the acetabulum following an acetabular bone defect revision, which enhances the hip joint function and eventually makes a satisfactory stable prosthetic.
引用
收藏
页码:1264 / 1271
页数:8
相关论文
共 50 条
  • [41] Aortic thrombosis after acetabular revision of a total hip arthroplasty
    Leung, AG
    Cabanela, ME
    JOURNAL OF ARTHROPLASTY, 1998, 13 (08): : 961 - 965
  • [42] Management strategies for acetabular defects in revision total hip arthroplasty
    Cuckler, JM
    JOURNAL OF ARTHROPLASTY, 2002, 17 (04): : 153 - 156
  • [43] Constrained acetabular components in complex revision total hip arthroplasty
    McCarthy, JC
    Lee, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 210 - 215
  • [44] Management of massive acetabular defects in revision total hip arthroplasty
    Dennis, DA
    JOURNAL OF ARTHROPLASTY, 2003, 18 (03): : 121 - 125
  • [45] Acetabular custom implants in the management of severe acetabular bone defects in revision total hip arthroplasty: a systematic review of the literature
    Zanirato, Andrea
    Quarto, Emanuele
    Coccarello, Francesco
    De Paolis, Matteo
    Spatuzzi, Marco
    Rossi, Gregorio
    Formica, Matteo
    MINERVA ORTHOPEDICS, 2024, 75 (01): : 71 - 80
  • [46] Biphasic bone graft substitute in revision total hip arthroplasty with significant acetabular bone defects
    McPherson, E. J.
    Stavrakis, A. I.
    Chowdhry, M.
    Curtin, N. L.
    V. Dipane, M.
    Crawford, B. M.
    BONE & JOINT OPEN, 2022, 3 (12): : 991 - 997
  • [47] Early results of Trabecular Metal augment for acetabular reconstruction in revision hip arthroplasty
    Elganzoury, Ibrahim
    Bassiony, Ayman Abdelaziz
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (05): : 530 - 535
  • [48] PRINCIPLES OF BONE-GRAFTING IN REVISION TOTAL HIP-ARTHROPLASTY - ACETABULAR TECHNIQUE
    PAPROSKY, WG
    MAGNUS, RE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (298) : 147 - 155
  • [50] The biological acetabular reconstruction with bone allografts in hip revision arthroplasty
    Busanelli L.
    Castagnini F.
    Bordini B.
    Stea S.
    Calderoni P.P.
    Toni A.
    MUSCULOSKELETAL SURGERY, 2019, 103 (2) : 173 - 179