Treatment of Acetabular Bone Defect in Revision of Total Hip Arthroplasty Using 3D Printed Tantalum Acetabular Augment

被引:12
|
作者
Ying, Jiawei [1 ]
Cheng, Liangliang [1 ]
Li, Junlei [1 ]
Wu, Bin [1 ]
Qiu, Xing [1 ]
Zhang, Tianwei [1 ]
Wang, Feng [1 ]
Liu, Baoyi [1 ]
Yang, Lei [1 ]
Pokharel, Durga Bhakta [1 ]
Xie, Hui [1 ]
Wang, Fuyang [1 ]
Liu, Yuchen [1 ]
Xu, Minghao [1 ]
Yu, Haiyu [1 ]
Zhao, Dewei [1 ]
机构
[1] Dalian Univ, Dept Orthopaed, Zhongshan Hosp, 6 Jiefang St, Dalian 116001, Liaoning, Peoples R China
关键词
3D printed; Acetabular bone defect; Customized augment; Revision of total hip arthroplasty; Tantalum; TRABECULAR METAL AUGMENTS; POROUS TANTALUM; RECONSTRUCTION;
D O I
10.1111/os.13691
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveThe treatment of acetabular defects is one of the most difficult challenges of revision of total hip arthroplasty (RTHA), and tantalum is regarded as a promising bone substitute material. This study aims to investigate the effectiveness of 3D printed acetabular augment used in RTHA for the treatment of acetabular bone defect. MethodsA retrospective analysis of the clinical data of seven patients who had undergone RTHA was carried out using 3D printed acetabular augment from January 2017 to December 2018. The CT data of the patients were exported to Mimics 21.0 software (Materialise, Leuven, Belgium), and the acetabular bone defect augment were designed, printed and then implanted during operation. The postoperative Harris score, visual analogue scale (VAS) score and prosthesis position were observed to evaluate the clinical outcome. A I-test was used for preoperative and postoperative comparison of the paired-design dataset. ResultsA firm attachment of the bone augment to the acetabulum during operation without any complications was found during the follow-up time 2.8-4.3 years. The VAS score of all patients was found 6.9 +/- 1.4 before operation and was 0.7 +/- 0.7 at the last follow-up (P <= 0.001), and the Harris hip scores, were 31.9 +/- 10.3 and 73.3 +/- 12.8 before operation, and at the last follow-up (P <= 0.001), respectively. Moreover, no loosening sign between the bone defect augment and the acetabulum was observed during the entire implantation period. Conclusion3D printed acetabular augment is effective in reconstructing the acetabulum following an acetabular bone defect revision, which enhances the hip joint function and eventually makes a satisfactory stable prosthetic.
引用
收藏
页码:1264 / 1271
页数:8
相关论文
共 50 条
  • [21] Cementless total hip arthroplasty with structural allograft for massive acetabular defect in hip revision
    Tian Jialiang
    Sun Li
    Hu Ruyin
    Tian Xiaobin
    CHINESE JOURNAL OF TRAUMATOLOGY, 2014, 17 (06) : 331 - 334
  • [22] 3D Printing Hip Prostheses Offer Accurate Reconstruction, Stable Fixation, and Functional Recovery for Revision Total Hip Arthroplasty with Complex Acetabular Bone Defect
    Hao, Yongqiang
    Wang, Lei
    Jiang, Wenbo
    Wu, Wen
    Ai, Songtao
    Shen, Lu
    Zhao, Shuang
    Dai, Kerong
    ENGINEERING, 2020, 6 (11) : 1285 - 1290
  • [23] Biological downsizing. Acetabular defect reconstruction in revision total hip arthroplasty
    Koob, S.
    Scheidt, S.
    Randau, T. M.
    Gathen, M.
    Wimmer, M. D.
    Wirtz, D. C.
    Gravius, S.
    ORTHOPADE, 2017, 46 (02): : 158 - 167
  • [24] Use of Porous Tantalum for Acetabular Reconstruction in Revision Hip Arthroplasty
    Issack, Paul S.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (21): : 1981 - 1987
  • [25] Modular Tantalum Augments for Acetabular Defects in Revision Hip Arthroplasty
    Siegmeth, Alexander
    Duncan, Clive P.
    Masri, Bassam A.
    Kim, Winston Y.
    Garbuz, Donald S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) : 199 - 205
  • [26] Minimum Five-Year Outcomes with Porous Tantalum Acetabular Cup and Augment Construct in Complex Revision Total Hip Arthroplasty
    Jenkins, Derek R.
    Odland, Andrew N.
    Sierra, Rafael J.
    Hanssen, Arlen D.
    Lewallen, David G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (10): : e49
  • [27] Cernentless acetabular reconstruction in revision total hip arthroplasty
    Della Valle, CJ
    Berger, RA
    Rosenberg, AG
    Galante, JO
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) : 96 - 100
  • [28] Revision Total Hip Arthroplasty with Retained Acetabular Component
    Adelani, Muyibat A.
    Mall, Nathan A.
    Nyazee, Humaa
    Clohisy, John C.
    Barrack, Robert L.
    Nunley, Ryan M.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (12): : 1015 - 1020
  • [29] The Use of Porous Tantalum Augments for the Reconstruction of Acetabular Defect in Primary Total Hip Arthroplasty
    Ling, Ting-Xian
    Li, Jin-Long
    Zhou, Kai
    Xiao, Qiang
    Pei, Fu-Xing
    Zhou, Zong-Ke
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 453 - 459
  • [30] 3D Printed Patient-Specific Acetabular Jig for Cup Placement in Total Hip Arthroplasty
    Abhishek Mishra
    Tarun Verma
    Gaurang Rajkumar
    Amit Agarwal
    Lalit Sharma
    Indian Journal of Orthopaedics, 2020, 54 : 174 - 180