Treatment of Acetabular Bone Defect in Revision of Total Hip Arthroplasty Using 3D Printed Tantalum Acetabular Augment

被引:12
|
作者
Ying, Jiawei [1 ]
Cheng, Liangliang [1 ]
Li, Junlei [1 ]
Wu, Bin [1 ]
Qiu, Xing [1 ]
Zhang, Tianwei [1 ]
Wang, Feng [1 ]
Liu, Baoyi [1 ]
Yang, Lei [1 ]
Pokharel, Durga Bhakta [1 ]
Xie, Hui [1 ]
Wang, Fuyang [1 ]
Liu, Yuchen [1 ]
Xu, Minghao [1 ]
Yu, Haiyu [1 ]
Zhao, Dewei [1 ]
机构
[1] Dalian Univ, Dept Orthopaed, Zhongshan Hosp, 6 Jiefang St, Dalian 116001, Liaoning, Peoples R China
关键词
3D printed; Acetabular bone defect; Customized augment; Revision of total hip arthroplasty; Tantalum; TRABECULAR METAL AUGMENTS; POROUS TANTALUM; RECONSTRUCTION;
D O I
10.1111/os.13691
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveThe treatment of acetabular defects is one of the most difficult challenges of revision of total hip arthroplasty (RTHA), and tantalum is regarded as a promising bone substitute material. This study aims to investigate the effectiveness of 3D printed acetabular augment used in RTHA for the treatment of acetabular bone defect. MethodsA retrospective analysis of the clinical data of seven patients who had undergone RTHA was carried out using 3D printed acetabular augment from January 2017 to December 2018. The CT data of the patients were exported to Mimics 21.0 software (Materialise, Leuven, Belgium), and the acetabular bone defect augment were designed, printed and then implanted during operation. The postoperative Harris score, visual analogue scale (VAS) score and prosthesis position were observed to evaluate the clinical outcome. A I-test was used for preoperative and postoperative comparison of the paired-design dataset. ResultsA firm attachment of the bone augment to the acetabulum during operation without any complications was found during the follow-up time 2.8-4.3 years. The VAS score of all patients was found 6.9 +/- 1.4 before operation and was 0.7 +/- 0.7 at the last follow-up (P <= 0.001), and the Harris hip scores, were 31.9 +/- 10.3 and 73.3 +/- 12.8 before operation, and at the last follow-up (P <= 0.001), respectively. Moreover, no loosening sign between the bone defect augment and the acetabulum was observed during the entire implantation period. Conclusion3D printed acetabular augment is effective in reconstructing the acetabulum following an acetabular bone defect revision, which enhances the hip joint function and eventually makes a satisfactory stable prosthetic.
引用
收藏
页码:1264 / 1271
页数:8
相关论文
共 50 条
  • [31] 3D Printed Patient-Specific Acetabular Jig for Cup Placement in Total Hip Arthroplasty
    Mishra, Abhishek
    Verma, Tarun
    Rajkumar
    Agarwal, Gaurang
    Sharma, Amit
    Maini, Lalit
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (02) : 174 - 180
  • [32] Bone remodeling after revision total hip arthroplasty for large acetabular defects
    Ramesh, Angelika
    Di Laura, Anna
    De Angelis, Sara
    Henckel, Johann
    Hart, Alister
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (12) : 2784 - 2795
  • [33] Treatment of acetabular bone defects in revision hip arthroplasty using the Revisio-System
    Hoberg, M.
    Holzapfel, B. M.
    Steinert, A. F.
    Kratzer, F.
    Walcher, M.
    Rudert, M.
    ORTHOPADE, 2017, 46 (02): : 126 - 132
  • [34] Management of massive acetabular bone defects in revision arthroplasty of the hip using a reconstruction cage and porous metal augment
    Makinen, T. J.
    Abolghasemian, M.
    Watts, E.
    Fichman, S. G.
    Kuzyk, P.
    Safir, O. A.
    Gross, A. E.
    BONE & JOINT JOURNAL, 2017, 99-B (05): : 607 - 613
  • [35] Cementless acetabular revision: Past, present, and future - Revision total hip arthroplasty: The acetabular side using cementless implants
    Pulido L.
    Rachala S.R.
    Cabanela M.E.
    International Orthopaedics, 2011, 35 (2) : 289 - 298
  • [36] Histological studies on retrieved HA granules filled in acetabular massive bone defect in revision total hip arthroplasty
    Oonishi, H
    Fujita, H
    Itoh, S
    Kin, T
    Oomamiuda, K
    BIOCERAMICS 14, 2002, 218-2 : 423 - 426
  • [37] What Characteristics of the Acetabular Defect Influence the Choice of the Acetabular Component During Revision Hip Arthroplasty?
    Tikhilov, R. M.
    Dzhavadov, A. A.
    Kovalenko, A. N.
    Denisov, A. O.
    Demin, A. S.
    Vahramyan, A. G.
    Shubnyakov, I. I.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2020, 26 (02): : 31 - 49
  • [38] Multiple Revision Surgeries and Acetabular Bone Defect Size May Predict Daily Activity After Revision Total Hip Arthroplasty
    Hayashi, Shinya
    Hashimoto, Shingo
    Takayama, Koji
    Matsumoto, Tomoyuki
    Nishida, Kotaro
    Kuroda, Ryosuke
    JOURNAL OF ARTHROPLASTY, 2017, 32 (05): : 1606 - 1611
  • [39] 3D-printed Personalized Porous Acetabular Component to Reconstruct Extensive Acetabular Bone Defects in Primary Hip Arthroplasty
    Li, Zhuangzhuang
    Luo, Yi
    Lu, Minxun
    Wang, Yitian
    Gong, Taojun
    Hu, Xin
    He, Xuanhong
    Zhou, Yong
    Min, Li
    Tu, Chongqi
    ORTHOPAEDIC SURGERY, 2024, 16 (07) : 1642 - 1647
  • [40] ACETABULAR PREPARATION IN CEMENTLESS REVISION TOTAL HIP-ARTHROPLASTY
    MCGANN, WA
    WELCH, RB
    PICETTI, GD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (235) : 35 - 46