CONTRIBUTION FACTORS OF EFFECTIVE LENS POSITION, TILT, AND DECENTRATION DURING FLANGED SCLERAL FIXATION OF INTRAOCULAR LENS

被引:2
|
作者
Park, Chang-Hyun [1 ]
Moon, Kun [2 ,3 ]
Kim, Jessica H. [4 ]
Shim, Kyu Young [3 ]
Jun, Jong Hwa [3 ,5 ,6 ]
机构
[1] Keimyung Univ, Sch Med, Daegu, South Korea
[2] Seoul Balgeunsesang Eye Clin, Seoul, South Korea
[3] Keimyung Univ, Sch Med, Dept Ophthalmol, Daegu, South Korea
[4] Univ Calif San Diego, Sch Med, San Diego, CA USA
[5] Shiley Eye Inst, Viterbi Family Dept Ophthalmol, San Diego, CA USA
[6] Keimyung Univ, Sch Med, Dept Ophthalmol, 1035 Dalgubeol Daero, Daegu 42601, South Korea
关键词
decentration; flanged; optical coherence tomography; scleral fixation; tilt; CHAMBER; IMPLANTATION; SUPPORT; ABSENCE;
D O I
10.1097/IAE.0000000000003960
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The authors aimed to elucidate the factors related to effective lens position, tilt, and decentration of scleral fixed intraocular lenses (IOLs) with a flanged haptic technique in an artificial eye model using anterior segment optical coherence tomography. Methods: Two bent 27-gauge needles were passed through a 1.0- or 2.0-mm scleral tunnel, 2.0 mm posterior to the limbus and 180 degrees apart. Both haptics of a three-piece IOL were docked with guide needles and externalized. Factors related to the IOL position were analyzed using anterior segment optical coherence tomography and a stereomicroscope. Results: The 1.0-mm scleral tunnel induced a significantly longer effective lens position than the 2.0-mm tunnel and suture fixation (P < 0.05 and P < 0.01, respectively). Discrepancy in scleral tunnel length induced higher decentration of the optic to the opposite side of the haptic-embedded shorter tunnel and tilt perpendicular to the fixed axis than that in the scleral tunnel of the same length (P < 0.001 and P < 0.05, respectively). If the scleral fixation points of both haptics are not exactly 180 degrees apart, the IOL may become decentered and tilted (P < 0.01 and P < 0.05, respectively). Conclusion: In the flanged haptic technique, the length, balance, and position of both scleral tunnels determine IOL effective lens position, tilt, and decentration.
引用
收藏
页码:324 / 332
页数:9
相关论文
共 50 条
  • [41] The effect of intraocular lens tilt on visual outcomes in scleral-fixated intraocular lens implantation
    Atik, Burcu Kemer
    Altan, Cigdem
    Agca, Alper
    Kirmaci, Asli
    Yildirim, Yusuf
    Genc, Selim
    Taskapil, Muhittin
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (03) : 717 - 724
  • [42] The effect of intraocular lens tilt on visual outcomes in scleral-fixated intraocular lens implantation
    Burcu Kemer Atik
    Cigdem Altan
    Alper Agca
    Asli Kirmaci
    Yusuf Yildirim
    Selim Genc
    Muhittin Taskapili
    International Ophthalmology, 2020, 40 : 717 - 724
  • [43] Ab externo scleral suture loop fixation for posterior chamber intraocular lens decentration: Clinical results
    Chan, CC
    Crandall, AS
    Ahmed, IIK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (01): : 121 - 128
  • [44] Intraocular lens tilt and decentration and wavefront aberrations in spheric and aspheric intraocular lenses
    Baumeister, M
    Bühren, J
    Kasper, T
    Kohnen, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [45] Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration
    Oshika, T.
    Sugita, G.
    Miyata, K.
    Tokunaga, T.
    Samejima, T.
    Okamoto, C.
    Ishii, Y.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (02) : 185 - 188
  • [46] Guidance needle for insertion of intraocular lens haptics into scleral tunnels during intrascleral lens fixation
    Kawashima, Yu
    Akimoto, Masayuki
    Taguchi, Hogara
    Hiroi, Kano
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (12): : 1844 - 1845
  • [47] Scleral Fixation of Intraocular Lens and Retropupillary Fixation of Iris Claw Lens for Aphakic Eyes
    Kim, Joo Young
    Park, Chang Hyun
    Whang, Woong Joo
    Na, Kyung Sun
    Kim, Hyun Seung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2019, 60 (07): : 643 - 653
  • [48] Influence of intraocular lens tilt and decentration on higher-order aberration after transscleral suture fixation
    Itoga, T
    Kiuchi, T
    Hiraoka, T
    Okamoto, F
    Sato, M
    Oshika, T
    Sugita, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U712 - U712
  • [49] Determination of Intraocular Lens Tilt and Decentration Using Simple and Rapid Method
    Mingxing Wu Huaming Li Weirong ChengZhongshan Ophthalmic Center Sun Yatsen University of Medical Sciences Guangzhou China
    眼科学报, 1998, (01) : 13 - 16+26
  • [50] Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation
    Teruaki Tokuhisa
    Tomoyuki Watanabe
    Akira Watanabe
    Tadashi Nakano
    International Ophthalmology, 2022, 42 : 1213 - 1220