CONTRIBUTION FACTORS OF EFFECTIVE LENS POSITION, TILT, AND DECENTRATION DURING FLANGED SCLERAL FIXATION OF INTRAOCULAR LENS

被引:2
|
作者
Park, Chang-Hyun [1 ]
Moon, Kun [2 ,3 ]
Kim, Jessica H. [4 ]
Shim, Kyu Young [3 ]
Jun, Jong Hwa [3 ,5 ,6 ]
机构
[1] Keimyung Univ, Sch Med, Daegu, South Korea
[2] Seoul Balgeunsesang Eye Clin, Seoul, South Korea
[3] Keimyung Univ, Sch Med, Dept Ophthalmol, Daegu, South Korea
[4] Univ Calif San Diego, Sch Med, San Diego, CA USA
[5] Shiley Eye Inst, Viterbi Family Dept Ophthalmol, San Diego, CA USA
[6] Keimyung Univ, Sch Med, Dept Ophthalmol, 1035 Dalgubeol Daero, Daegu 42601, South Korea
关键词
decentration; flanged; optical coherence tomography; scleral fixation; tilt; CHAMBER; IMPLANTATION; SUPPORT; ABSENCE;
D O I
10.1097/IAE.0000000000003960
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The authors aimed to elucidate the factors related to effective lens position, tilt, and decentration of scleral fixed intraocular lenses (IOLs) with a flanged haptic technique in an artificial eye model using anterior segment optical coherence tomography. Methods: Two bent 27-gauge needles were passed through a 1.0- or 2.0-mm scleral tunnel, 2.0 mm posterior to the limbus and 180 degrees apart. Both haptics of a three-piece IOL were docked with guide needles and externalized. Factors related to the IOL position were analyzed using anterior segment optical coherence tomography and a stereomicroscope. Results: The 1.0-mm scleral tunnel induced a significantly longer effective lens position than the 2.0-mm tunnel and suture fixation (P < 0.05 and P < 0.01, respectively). Discrepancy in scleral tunnel length induced higher decentration of the optic to the opposite side of the haptic-embedded shorter tunnel and tilt perpendicular to the fixed axis than that in the scleral tunnel of the same length (P < 0.001 and P < 0.05, respectively). If the scleral fixation points of both haptics are not exactly 180 degrees apart, the IOL may become decentered and tilted (P < 0.01 and P < 0.05, respectively). Conclusion: In the flanged haptic technique, the length, balance, and position of both scleral tunnels determine IOL effective lens position, tilt, and decentration.
引用
收藏
页码:324 / 332
页数:9
相关论文
共 50 条
  • [31] Intraocular lens tilt and decentration: A concern for contemporary IOL designs
    Ale, Jit B.
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2011, 3 (01) : 68 - 77
  • [32] Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (11) : 1294 - 1297
  • [33] Ab externo scleral fixation of intraocular lens
    Slade, D. Snow
    Hater, Michael A.
    Cionni, Robert J.
    Crandall, Alan S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (08): : 1316 - 1321
  • [34] Flattened flanged intrascleral intraocular lens fixation technique
    Ucar, Fikret
    Cetinkaya, Servet
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (06) : 1455 - 1460
  • [35] Flanged intrascleral intraocular lens fixation with a single needle
    Hwang, Eileen S.
    Warren, Clinton C.
    Koenig, Steven B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (12): : 1526 - 1527
  • [36] Flattened flanged intrascleral intraocular lens fixation technique
    Fikret Ucar
    Servet Cetinkaya
    International Ophthalmology, 2020, 40 : 1455 - 1460
  • [37] Comparison of flanged intrascleral intraocular lens fixation versus iris claw intraocular lens fixation: A retrospective study
    Kelkar, Aditya S.
    Kelkar, Jai A.
    Kothari, Akshay A.
    Kelkar, Shreekant B.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (11) : 1838 - 1842
  • [38] Intraocular Lens Formula Comparison of Flanged Intrascleral Intraocular Lens Fixation with Double Needle Technique
    Malach, Daniel S.
    Guest, John Michael
    Adam, Christopher
    Joffe, Jonah
    Le, Kim
    Kim, Chaesik
    Lin, Xihui
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 837 - 842
  • [39] Reinforced scleral fixation of foldable intraocular lens by double sutures: comparison with intrascleral intraocular lens fixation
    Chantarasorn, Yodpong
    Techalertsuwan, Settapong
    Siripanthong, Pongsavit
    Tamerug, Anurak
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2018, 62 (03) : 365 - 372
  • [40] Reinforced scleral fixation of foldable intraocular lens by double sutures: comparison with intrascleral intraocular lens fixation
    Yodpong Chantarasorn
    Settapong Techalertsuwan
    Pongsavit Siripanthong
    Anurak Tamerug
    Japanese Journal of Ophthalmology, 2018, 62 : 365 - 372