CONTRIBUTION FACTORS OF EFFECTIVE LENS POSITION, TILT, AND DECENTRATION DURING FLANGED SCLERAL FIXATION OF INTRAOCULAR LENS

被引:2
|
作者
Park, Chang-Hyun [1 ]
Moon, Kun [2 ,3 ]
Kim, Jessica H. [4 ]
Shim, Kyu Young [3 ]
Jun, Jong Hwa [3 ,5 ,6 ]
机构
[1] Keimyung Univ, Sch Med, Daegu, South Korea
[2] Seoul Balgeunsesang Eye Clin, Seoul, South Korea
[3] Keimyung Univ, Sch Med, Dept Ophthalmol, Daegu, South Korea
[4] Univ Calif San Diego, Sch Med, San Diego, CA USA
[5] Shiley Eye Inst, Viterbi Family Dept Ophthalmol, San Diego, CA USA
[6] Keimyung Univ, Sch Med, Dept Ophthalmol, 1035 Dalgubeol Daero, Daegu 42601, South Korea
关键词
decentration; flanged; optical coherence tomography; scleral fixation; tilt; CHAMBER; IMPLANTATION; SUPPORT; ABSENCE;
D O I
10.1097/IAE.0000000000003960
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The authors aimed to elucidate the factors related to effective lens position, tilt, and decentration of scleral fixed intraocular lenses (IOLs) with a flanged haptic technique in an artificial eye model using anterior segment optical coherence tomography. Methods: Two bent 27-gauge needles were passed through a 1.0- or 2.0-mm scleral tunnel, 2.0 mm posterior to the limbus and 180 degrees apart. Both haptics of a three-piece IOL were docked with guide needles and externalized. Factors related to the IOL position were analyzed using anterior segment optical coherence tomography and a stereomicroscope. Results: The 1.0-mm scleral tunnel induced a significantly longer effective lens position than the 2.0-mm tunnel and suture fixation (P < 0.05 and P < 0.01, respectively). Discrepancy in scleral tunnel length induced higher decentration of the optic to the opposite side of the haptic-embedded shorter tunnel and tilt perpendicular to the fixed axis than that in the scleral tunnel of the same length (P < 0.001 and P < 0.05, respectively). If the scleral fixation points of both haptics are not exactly 180 degrees apart, the IOL may become decentered and tilted (P < 0.01 and P < 0.05, respectively). Conclusion: In the flanged haptic technique, the length, balance, and position of both scleral tunnels determine IOL effective lens position, tilt, and decentration.
引用
收藏
页码:324 / 332
页数:9
相关论文
共 50 条
  • [21] REDUCING TILT AND DECENTRATION OF SUTURED INTRAOCULAR-LENS IMPLANTS
    SOSSI, NP
    FRUEH, BE
    FELDMAN, ST
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 796 - 796
  • [22] Four-flanged Technique for Scleral Fixation of a Dislocated Four-eyelet Intraocular Lens
    Lim, Byung Su
    Kwon, Jun Su
    Won, Jae Yon
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (09): : 803 - 810
  • [23] Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens
    Eom, Youngsub
    Koh, Eunheh
    Yang, Seul Ki
    Kim, Soo
    Yi, Sungtae
    Jeon, Hyun Sun
    Kim, Seong-Jae
    So, Jason
    Song, Jong Suk
    Cooke, David L.
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [24] 6/0 PROLENE DOUBLE-FLANGED INTRAOCULAR LENS SUTURELESS SCLERAL FIXATION WITH A 27-GAUGE NEEDLE FOR INTRAOCULAR LENS SURGERY
    Pao, Shu-I.
    Chang, Yun-Hsiang
    Chen, Jiann-Torng
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2025, 45 (02): : 278 - 285
  • [25] TILT AND DECENTRATION OF THE IMPLANTED POSTERIOR CHAMBER INTRAOCULAR-LENS
    KOZAKI, J
    TANIHARA, H
    YASUDA, A
    NAGATA, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (05): : 592 - 595
  • [26] Evaluation of Decentration, Tilt and Angular Orientation of Toric Intraocular Lens
    Fus, Martin
    Pitrova, Sarka
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 4755 - 4761
  • [27] Intraocular lens tilt and decentration after implantation in eyes with glaucoma
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (11): : 1515 - 1520
  • [28] Impact of intraocular lens haptic design and orientation on decentration and tilt
    Crnej, Alja
    Hirnschall, Nino
    Nishi, Yutaro
    Gangwani, Vinod
    Tabernero, Juan
    Artal, Pablo
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (10): : 1768 - 1774
  • [29] Determinants of intraocular lens tilt and decentration after cataract surgery
    Gu, Xiaoxun
    Chen, Xiaoyun
    Yang, Guangyao
    Wang, Wei
    Xiao, Wei
    Jin, Guangming
    Wang, Lanhua
    Dai, Ye
    Ruan, Xiaoting
    Liu, Zhenzhen
    Luo, Lixia
    Liu, Yizhi
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (15)
  • [30] Decentration, tilt, and near vision of the Array multifocal intraocular lens
    Yang, HC
    Chung, SK
    Baek, NH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (04): : 586 - 589