CONTRIBUTION FACTORS OF EFFECTIVE LENS POSITION, TILT, AND DECENTRATION DURING FLANGED SCLERAL FIXATION OF INTRAOCULAR LENS

被引:2
|
作者
Park, Chang-Hyun [1 ]
Moon, Kun [2 ,3 ]
Kim, Jessica H. [4 ]
Shim, Kyu Young [3 ]
Jun, Jong Hwa [3 ,5 ,6 ]
机构
[1] Keimyung Univ, Sch Med, Daegu, South Korea
[2] Seoul Balgeunsesang Eye Clin, Seoul, South Korea
[3] Keimyung Univ, Sch Med, Dept Ophthalmol, Daegu, South Korea
[4] Univ Calif San Diego, Sch Med, San Diego, CA USA
[5] Shiley Eye Inst, Viterbi Family Dept Ophthalmol, San Diego, CA USA
[6] Keimyung Univ, Sch Med, Dept Ophthalmol, 1035 Dalgubeol Daero, Daegu 42601, South Korea
关键词
decentration; flanged; optical coherence tomography; scleral fixation; tilt; CHAMBER; IMPLANTATION; SUPPORT; ABSENCE;
D O I
10.1097/IAE.0000000000003960
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The authors aimed to elucidate the factors related to effective lens position, tilt, and decentration of scleral fixed intraocular lenses (IOLs) with a flanged haptic technique in an artificial eye model using anterior segment optical coherence tomography. Methods: Two bent 27-gauge needles were passed through a 1.0- or 2.0-mm scleral tunnel, 2.0 mm posterior to the limbus and 180 degrees apart. Both haptics of a three-piece IOL were docked with guide needles and externalized. Factors related to the IOL position were analyzed using anterior segment optical coherence tomography and a stereomicroscope. Results: The 1.0-mm scleral tunnel induced a significantly longer effective lens position than the 2.0-mm tunnel and suture fixation (P < 0.05 and P < 0.01, respectively). Discrepancy in scleral tunnel length induced higher decentration of the optic to the opposite side of the haptic-embedded shorter tunnel and tilt perpendicular to the fixed axis than that in the scleral tunnel of the same length (P < 0.001 and P < 0.05, respectively). If the scleral fixation points of both haptics are not exactly 180 degrees apart, the IOL may become decentered and tilted (P < 0.01 and P < 0.05, respectively). Conclusion: In the flanged haptic technique, the length, balance, and position of both scleral tunnels determine IOL effective lens position, tilt, and decentration.
引用
收藏
页码:324 / 332
页数:9
相关论文
共 50 条
  • [1] Comparison of flanged polypropylene scleral intraocular lens fixation with scleral sutured fixation
    Levy-Neuman, Shani
    Mendel, Liat
    Achiron, Asaf
    Bukelman, Amir
    Weinberg, Tamir
    Avizemer, Haggay
    Schlesinger, Mor
    Marcovich, Arie L.
    Kleinmann, Guy
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2024, 59 (06): : e653 - e660
  • [2] Scheimpflug imaging for evaluation of intraocular lens position in modified flanged scleral fixated intraocular lens
    Oli, Avadhesh
    Yadav, Anil
    Babu, J. Ganesh
    Balakrishnan, Divya
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2023, 15
  • [3] Comparison of decentration, tilt and lenticular astigmatism of intraocular lens between sutured and sutureless scleral fixation techniques
    Sul, S.
    Kaderli, A.
    Karalezli, A.
    Kaya, C.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (08): : 1174 - 1179
  • [4] Capsular phimosis with intraocular lens tilt and decentration
    Chee, Soon-Phaik
    Dick, H. Burkhard
    Masket, Samuel
    Beltz, Jacqueline
    Vajpayee, Rasik B.
    Yeu, Elizabeth
    Zhu, Dagny
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (10): : 1073 - 1077
  • [5] A 1-Year Prospective Comparative Study of Sutureless Flanged Intraocular Lens Fixation and Conventional Sutured Scleral Fixation in Intraocular Lens Dislocation
    Do, Jae Rock
    Park, Su Jin
    Mukai, Ryo
    Kim, Hong Kyun
    Shin, Jae Pil
    Park, Dong Ho
    OPHTHALMOLOGICA, 2021, 244 (01) : 68 - 75
  • [6] Repositioned versus exchanged flanged intraocular lens fixation for intraocular lens dislocation
    Yong Koo Kang
    Dong Ho Park
    Gahyung Ryu
    Hong Kyun Kim
    Dong Hyun Kim
    Jae Rock Do
    Scientific Reports, 14
  • [7] NEEDLE STABILIZER FOR FLANGED INTRAOCULAR LENS FIXATION
    Yamane, Shin
    Maruyama-Inoue, Maiko
    Kadonosono, Kazuaki
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (04): : 801 - 801
  • [8] A comparative study of transscleral sutured intraocular lens fixation and sutureless flanged intraocular lens fixation
    Cui, Ying
    Li, Qiyan
    Shi, Xiangyu
    Zhou, Dan
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [9] A comparative study of transscleral sutured intraocular lens fixation and sutureless flanged intraocular lens fixation
    Ying Cui
    Qiyan Li
    Xiangyu Shi
    Dan Zhou
    BMC Ophthalmology, 23
  • [10] Scleral fixation of a foldable intraocular lens
    Michaeli-Cohen, A
    Rootman, DS
    OPHTHALMIC SURGERY AND LASERS, 2002, 33 (03): : 257 - 259