An electrolytic bubble column with an external hollow fiber membrane gas-liquid contactor for effective microbial electrosynthesis of acetate from CO2

被引:16
|
作者
Cui, Kai [1 ]
Guo, Kun [1 ,2 ]
Carvajal-Arroyo, Jose M. [2 ]
Arends, Jan [2 ]
Rabaey, Korneel [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Chem Engn & Technol, Xianning Rd 28, Xian 710049, Shaanxi, Peoples R China
[2] Univ Ghent, Ctr Microbial Ecol & Technol, Coupure Links 653, B-9000 Ghent, Belgium
基金
中国国家自然科学基金;
关键词
Microbial electrosynthesis; Bubble column reactor; Electrolytic hydrogen bubbles; H 2-mediated electron transfer; CO; 2; biotransformation; Acetate production; ELECTRICITY-DRIVEN BIOPRODUCTION; LONG-TERM OPERATION; BIOELECTROCHEMICAL SYSTEMS; HYDROGEN NANOBUBBLES; CARBON-DIOXIDE; ACETIC-ACID; CHEMICALS; WATER; FERMENTATION; METHANE;
D O I
10.1016/j.cej.2023.144296
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Currently, almost all microbial electrosynthesis (MES) reactors were biofilm-driven whether the cathode electron transfer was direct or indirect. It has been proven that cathode biofilm formation is time-consuming, and the current density achieved on these biofilms was relatively low. However, the main challenge for the non-biofilmdriven MES is how to maintain a good Columbic efficiency (CE) at high current densities. Here, we report a novel electro-H2 bubble column reactor with an external hollow fiber membrane gas-liquid contactor to tackle the challenge. The electrolyzer was placed at the bottom of the reactor to produce H2 micro-bubbles (mean diameter 169 & PLUSMN; 7 & mu;m) at a current density of 156 A/m2. The bubble column was put on the top of the cathodic chamber of the electrolyzer to extend the H2 retention time, while the hollow fiber membrane gas-liquid contactor in the external loop was used to recover the unused gas. Consequently, the homoacetogens in reactor could efficiently convert the electrolytically-produced H2 and the externally-supplied CO2 into acetate. The volume of the catholyte (5.5 L) in this reactor is one order of magnitude higher than all reported MES reactors. Batch tests with enriched homoacetogens demonstrated a maximum acetate production rate (1.15 g/Lcatholyte/d, 898 g/m2cathode/ d), acetate titer (34.5 g/L) could be achieved in this setup, and the average (maximum) CE of the electron to acetate efficiency was 64% (92%). Besides, dissolved H2 measurement and bacteria community analysis indicated the high acetate titers were likely caused by the H2 oversaturation situation and good substrate/product mass transfer rather than the selection of certain types of homoacetogens. The electro-H2 bubble reactor seems to be a promising MES setup for scale-up and practical application.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Absorption of SO2 from flue gas using PVDF hollow fiber membranes in a gas-liquid contactor
    Park, Hyun Hee
    Deshwal, Bal Raj
    Kim, In Won
    Lee, Hyung Keun
    JOURNAL OF MEMBRANE SCIENCE, 2008, 319 (1-2) : 29 - 37
  • [42] Enhancing the gas-liquid mass transfer during microbial electrosynthesis by the variation of CO2 flow rate
    Anzola Rojas, Melida del Pilar
    Zaiat, Marcelo
    Gonzalez, Ernesto Rafael
    De Wever, Heleen
    Pant, Deepak
    PROCESS BIOCHEMISTRY, 2021, 101 : 50 - 58
  • [43] The effect of heat treatment on hollow fiber membrane contactor for CO2 stripping
    Hashemifard, S. A.
    Ahmadi, H.
    Ismail, A. F.
    Moarefian, Ahmad
    Abdullah, M. S.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 223 : 186 - 195
  • [44] Experimental studies on CO2 absorption in immersed hollow fiber membrane contactor
    Wu, Xiaona
    Wang, Liang
    Zhang, Zhaohui
    Li, Wenyang
    Guo, Xingfei
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 1571 - 1575
  • [45] Modeling and experimental study of CO2 absorption in a hollow fiber membrane contactor
    Zhang, Hong-Yan
    Wang, Rong
    Liang, David Tee
    Tay, Joo Hwa
    JOURNAL OF MEMBRANE SCIENCE, 2006, 279 (1-2) : 301 - 310
  • [46] CO2 absorption at elevated pressures using a hollow fiber membrane contactor
    Dindore, VY
    Brilman, DWF
    Feron, PHM
    Versteeg, GF
    JOURNAL OF MEMBRANE SCIENCE, 2004, 235 (1-2) : 99 - 109
  • [47] CO2 stripping from water through porous PVDF hollow fiber membrane contactor
    Mansourizadeh, A.
    Ismail, A. F.
    DESALINATION, 2011, 273 (2-3) : 386 - 390
  • [48] Development of asymmetric polysulfone hollow fiber membrane contactor for CO2 absorption
    Rahbari-Sisakht, M.
    Ismail, A. F.
    Matsuura, T.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 86 : 215 - 220
  • [49] Modeling and experimental study of CO2 absorption in a hollow fiber membrane contactor
    School of Civil and Environmental Engineering, Nanyang Technological University, Singapore, 639798, Singapore
    不详
    J. Membr. Sci., 2006, 1-2 (301-310):
  • [50] CO2 capture in a hollow fiber membrane contactor coupled with ionic liquid: Influence of membrane wetting and process parameters
    Qazi, Sohaib
    Gomez-Coma, Lucia
    Albo, Jonathan
    Druon-Bocquet, Stephanie
    Irabien, Angel
    Sanchez-Marcano, Jose
    SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 233