An electrolytic bubble column with an external hollow fiber membrane gas-liquid contactor for effective microbial electrosynthesis of acetate from CO2

被引:16
|
作者
Cui, Kai [1 ]
Guo, Kun [1 ,2 ]
Carvajal-Arroyo, Jose M. [2 ]
Arends, Jan [2 ]
Rabaey, Korneel [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Chem Engn & Technol, Xianning Rd 28, Xian 710049, Shaanxi, Peoples R China
[2] Univ Ghent, Ctr Microbial Ecol & Technol, Coupure Links 653, B-9000 Ghent, Belgium
基金
中国国家自然科学基金;
关键词
Microbial electrosynthesis; Bubble column reactor; Electrolytic hydrogen bubbles; H 2-mediated electron transfer; CO; 2; biotransformation; Acetate production; ELECTRICITY-DRIVEN BIOPRODUCTION; LONG-TERM OPERATION; BIOELECTROCHEMICAL SYSTEMS; HYDROGEN NANOBUBBLES; CARBON-DIOXIDE; ACETIC-ACID; CHEMICALS; WATER; FERMENTATION; METHANE;
D O I
10.1016/j.cej.2023.144296
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Currently, almost all microbial electrosynthesis (MES) reactors were biofilm-driven whether the cathode electron transfer was direct or indirect. It has been proven that cathode biofilm formation is time-consuming, and the current density achieved on these biofilms was relatively low. However, the main challenge for the non-biofilmdriven MES is how to maintain a good Columbic efficiency (CE) at high current densities. Here, we report a novel electro-H2 bubble column reactor with an external hollow fiber membrane gas-liquid contactor to tackle the challenge. The electrolyzer was placed at the bottom of the reactor to produce H2 micro-bubbles (mean diameter 169 & PLUSMN; 7 & mu;m) at a current density of 156 A/m2. The bubble column was put on the top of the cathodic chamber of the electrolyzer to extend the H2 retention time, while the hollow fiber membrane gas-liquid contactor in the external loop was used to recover the unused gas. Consequently, the homoacetogens in reactor could efficiently convert the electrolytically-produced H2 and the externally-supplied CO2 into acetate. The volume of the catholyte (5.5 L) in this reactor is one order of magnitude higher than all reported MES reactors. Batch tests with enriched homoacetogens demonstrated a maximum acetate production rate (1.15 g/Lcatholyte/d, 898 g/m2cathode/ d), acetate titer (34.5 g/L) could be achieved in this setup, and the average (maximum) CE of the electron to acetate efficiency was 64% (92%). Besides, dissolved H2 measurement and bacteria community analysis indicated the high acetate titers were likely caused by the H2 oversaturation situation and good substrate/product mass transfer rather than the selection of certain types of homoacetogens. The electro-H2 bubble reactor seems to be a promising MES setup for scale-up and practical application.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Experimental Study of CO2 Absorption in a Hollow Fiber Membrane Contactor
    Kallas, Therese
    Chabanon, Elodie
    Germain, Guillaume
    Bouallou, Chakib
    PRES'09: 12TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1 AND 2, 2009, 18 : 267 - 272
  • [32] Investigation of H2S and CO2 Removal from Gas Streams Using Hollow Fiber Membrane Gas-liquid Contactors
    Mirfendereski, M.
    Mohammadi, T.
    CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 2017, 31 (02) : 139 - 144
  • [33] FUNDAMENTAL-STUDY OF CO2 REMOVAL FROM THERMAL POWER-PLANT FLUE-GAS BY HOLLOW-FIBER GAS-LIQUID CONTACTOR
    MATSUMOTO, H
    KITAMURA, H
    KAMATA, T
    NISHIKAWA, N
    ISHIBASHI, M
    KAGAKU KOGAKU RONBUNSHU, 1992, 18 (06) : 804 - 812
  • [34] Effect of polymer extrusion temperature on poly(vinylidene fluoride) hollow fiber membranes: Properties and performance used as gas-liquid membrane contactor for CO2 absorption
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Rahim, Nihmiya Abdul
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 99 : 91 - 103
  • [35] An analytical study of laminar concurrent flow membrane absorption through a hollow fiber gas-liquid membrane contactor
    Ho, Chii-Dong
    Sung, Yun-Jen
    Chuang, Yu-Chuan
    JOURNAL OF MEMBRANE SCIENCE, 2013, 428 : 232 - 240
  • [36] Rotating liquid sheet contactor: A new gas-liquid contactor system in CO2 absorption by nanofluids
    Mehdipour, Morteza
    Keshavarz, Peyman
    Rahimpour, Mohammad Reza
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2021, 165
  • [37] Preparation of PVDF Hollow Fiber Membrane and Absorption of SO2 from Flue Gas Using Bench Scale Gas-Liquid Contactor
    Park, Hyun-Hee
    Jo, Hang-Dae
    Kim, In-Won
    Lee, Hyung-Keun
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2008, 46 (03): : 521 - 528
  • [38] PERFORMANCE OF HOLLOW FIBER MEMBRANE GAS-LIQUID CONTACTORS TO ABSORB CO2 USING DIETHANOLAMINE (DEA) AS A SOLVENT
    Kartohardjono, Sutrasno
    Nata, Pan Ade
    Prasetio, Eko
    Yuliusman
    MAKARA JOURNAL OF TECHNOLOGY, 2009, 13 (02): : 86 - 90
  • [39] Preparation and characterization of OH/SiO2-TiO2/PES composite hollow fiber membrane using gas-liquid membrane contactor for CO2/CH4 separation
    Lin, Zhengda
    Liu, Yijun
    Zhang, Zhongming
    Yao, Jie
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 288
  • [40] Polysulfone porous hollow fiber membranes for ethylene-ethane separation in gas-liquid membrane contactor
    Ovcharova, Anna
    Vasilevsky, Vladimir
    Borisov, Ilya
    Bazhenov, Stepan
    Volkov, Alexey
    Bildyukevich, Alexandr
    Volkov, Vladimir
    SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 183 : 162 - 172