An electrolytic bubble column with an external hollow fiber membrane gas-liquid contactor for effective microbial electrosynthesis of acetate from CO2

被引:16
|
作者
Cui, Kai [1 ]
Guo, Kun [1 ,2 ]
Carvajal-Arroyo, Jose M. [2 ]
Arends, Jan [2 ]
Rabaey, Korneel [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Chem Engn & Technol, Xianning Rd 28, Xian 710049, Shaanxi, Peoples R China
[2] Univ Ghent, Ctr Microbial Ecol & Technol, Coupure Links 653, B-9000 Ghent, Belgium
基金
中国国家自然科学基金;
关键词
Microbial electrosynthesis; Bubble column reactor; Electrolytic hydrogen bubbles; H 2-mediated electron transfer; CO; 2; biotransformation; Acetate production; ELECTRICITY-DRIVEN BIOPRODUCTION; LONG-TERM OPERATION; BIOELECTROCHEMICAL SYSTEMS; HYDROGEN NANOBUBBLES; CARBON-DIOXIDE; ACETIC-ACID; CHEMICALS; WATER; FERMENTATION; METHANE;
D O I
10.1016/j.cej.2023.144296
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Currently, almost all microbial electrosynthesis (MES) reactors were biofilm-driven whether the cathode electron transfer was direct or indirect. It has been proven that cathode biofilm formation is time-consuming, and the current density achieved on these biofilms was relatively low. However, the main challenge for the non-biofilmdriven MES is how to maintain a good Columbic efficiency (CE) at high current densities. Here, we report a novel electro-H2 bubble column reactor with an external hollow fiber membrane gas-liquid contactor to tackle the challenge. The electrolyzer was placed at the bottom of the reactor to produce H2 micro-bubbles (mean diameter 169 & PLUSMN; 7 & mu;m) at a current density of 156 A/m2. The bubble column was put on the top of the cathodic chamber of the electrolyzer to extend the H2 retention time, while the hollow fiber membrane gas-liquid contactor in the external loop was used to recover the unused gas. Consequently, the homoacetogens in reactor could efficiently convert the electrolytically-produced H2 and the externally-supplied CO2 into acetate. The volume of the catholyte (5.5 L) in this reactor is one order of magnitude higher than all reported MES reactors. Batch tests with enriched homoacetogens demonstrated a maximum acetate production rate (1.15 g/Lcatholyte/d, 898 g/m2cathode/ d), acetate titer (34.5 g/L) could be achieved in this setup, and the average (maximum) CE of the electron to acetate efficiency was 64% (92%). Besides, dissolved H2 measurement and bacteria community analysis indicated the high acetate titers were likely caused by the H2 oversaturation situation and good substrate/product mass transfer rather than the selection of certain types of homoacetogens. The electro-H2 bubble reactor seems to be a promising MES setup for scale-up and practical application.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A novel process for oxygen absorption from air using hollow fiber gas-liquid membrane contactor
    Banazadeh, H.
    Mousavi, S. M.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 193 : 283 - 288
  • [22] Performance improvement of countercurrent-flow membrane gas absorption in a hollow fiber gas-liquid membrane contactor
    Ho, Chii-Dong
    Sung, Yun-Jen
    Chen, Wei-Ting
    Tsai, Feng-Chi
    MEMBRANE WATER TREATMENT, 2017, 8 (01) : 35 - 50
  • [23] EFFECT OF MEMBRANE-PROPERTIES OF MICROPOROUS HOLLOW-FIBER GAS-LIQUID CONTACTOR ON CO2 REMOVAL FROM THERMAL POWER-PLANT FLUE-GAS
    MATSUMOTO, H
    KITAMURA, H
    KAMATA, T
    ISHIBASHI, M
    OTA, H
    AKUTSU, N
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1995, 28 (01) : 125 - 128
  • [24] Improved CO2 Absorption in a Gas-Liquid Countercurrent Column Using a Ceramic Foam Contactor
    Wang, Zhen
    Gupta, Mayank
    Warudkar, Sumedh S.
    Cox, Kenneth R.
    Hirasaki, George J.
    Wong, Michael S.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (05) : 1387 - 1400
  • [25] Study of an innovative gas-liquid contactor for CO2 absorption
    Chabanon, E.
    Bouallou, C.
    Remigy, J. C.
    Lasseuguette, E.
    Medina, Y.
    Favre, E.
    Nguyen, P. T.
    Roizard, D.
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 1769 - 1776
  • [26] Modeling of CO2 Stripping in a Hollow Fiber Membrane Contactor for CO2 Capture
    Wang, Zhen
    Fang, Mengxiang
    Yu, Hai
    Ma, Qinhui
    Luo, Zhongyang
    ENERGY & FUELS, 2013, 27 (11) : 6887 - 6898
  • [27] Cyclic olefin polymer membrane as an emerging material for CO2 capture in gas-liquid membrane contactor
    Sabzekar, Malihe
    Chenar, Mahdi Pourafshari
    Khayet, Mohamed
    Garcia-Payo, Carmen
    Maghsoud, Zahra
    Pagliero, Marcello
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2022, 10 (03):
  • [28] Hydrophobicity optimization of polypropylene hollow fiber membrane by sol-gel process for CO2 absorption in gas-liquid membrane contactor using response surface methodology
    Amirabedi, Parya
    Yegani, Reza
    Hesaraki, Amir Hossein
    IRANIAN POLYMER JOURNAL, 2017, 26 (06) : 431 - 443
  • [29] Investigation of membrane wetting for CO2 capture by gas-liquid contactor based on ceramic membrane br
    Xue, Kaili
    Fu, Hongming
    Chen, Haiping
    Zhang, Heng
    Gao, Dan
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 304
  • [30] Hollow fiber membrane contactor hybrid system for CO2 recovery
    Lee, KH
    Yeon, SH
    Sea, B
    Park, YI
    CARBON DIOXIDE UTILIZATION FOR GLOBAL SUSTAINABILITY, 2004, 153 : 423 - 428