Risk evaluation of adverse aortic events in patients with non-circular aortic annulus after transcatheter aortic valve implantation: a numerical study

被引:4
|
作者
Wen, Jun [1 ]
Gao, Qi [2 ]
Chen, Jingnan [2 ]
Li, Xinya [2 ]
Zhang, Kaiyue [1 ]
He, Gang [1 ,3 ]
Dai, Min [4 ]
Song, Pan [4 ]
机构
[1] Southwest Univ Sci & Technol, Sch Comp Sci & Technol, Qinglong Rd 56, Mianyang 621010, Peoples R China
[2] Southwest Univ Sci & Technol, Inst Civil Engn & Architecture, Mianyang 621010, Peoples R China
[3] Mianyang Cent Hosp, NHC Key Lab Nucl Technol Med Transformat, Mianyang 621010, Peoples R China
[4] Mianyang Cent Hosp, Dept Cardiol, 12 Changjia Lane,Jingzhong St, Mianyang 621000, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Transcatheter aortic valve implantation; Hemodynamic; Annulus; Non-circular; Computational fluid dynamics; COMPUTATIONAL MODEL; FLUID-MECHANICS; MASS-TRANSFER; SHEAR-STRESS; FLOW; TRANSPORT; ENDOTHELIUM; SIMULATION; SYSTEMS; BYPASS;
D O I
10.1007/s10237-023-01725-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Transcatheter aortic valve implantation (TAVI) is a micro-invasive surgery used to treat patients with aortic stenosis (AS) efficiently. However, the uneven valve expansion can cause a non-circular annulus, which is one of the main factors leading to complications after TAVI. As a preliminary work, the main purpose of this study was to evaluate the risk of adverse aortic events in patients with a non-circular aortic annulus after TAVI. This study numerically investigated the distribution of four wall shear stress (WSS)-based indicators and three helicity-based indicators in eight patient-specific aortas with different annulus including circular, type I elliptical and type II elliptical shapes. Both elliptical annulus features can significantly enhance the intensity of the helicity (h2) in the ascending aorta (p < 0.001). However, for the type I elliptical annulus, the spiral flow structure was changed into low-velocity and disturbed flow pattern close to the inner side of the aortic arch. For the type II elliptical annulus, the spiral flow remained but became skewed in distribution. The elliptical annulus feature could increase the general level WSS-based indicators, especially in the ascending aorta. However, due to the disturbance of spiral flow or second helical flow in ascending aortas, areas with low TAWSS accompanied by high oscillatory shear index (OSI) and cross flow index (CFI) were observed in all the ascending aortas with non-circular annulus. The elliptical annulus feature can change the hemodynamic environment in the aortic arch, especially in the ascending aorta. Although both elliptical annulus features enhanced the strength of helicity, the uniform distribution of the helical flow was disturbed, especially in the ascending aorta, indicating the potential risk of adverse aortic events may increase. Therefore, for the patients without paravalvular leak but elliptical annulus shape after TAVI treatment, surgeons may be needed to consider further dilatation to make the non-circular annulus become circular.
引用
收藏
页码:1379 / 1394
页数:16
相关论文
共 50 条
  • [41] Transcatheter aortic valve implantation for Chinese patients with bicuspid aortic valve
    Weng, Yu-guo
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2015, 16 (04): : 327 - 328
  • [42] Transcatheter aortic valve implantation for Chinese patients with bicuspid aortic valve
    Yu-guo WENG
    Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2015, (04) : 327 - 328
  • [43] Transcatheter aortic valve implantation for Chinese patients with bicuspid aortic valve
    Yu-guo WENG
    Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2015, 16 (04) : 327 - 328
  • [44] Preventive Landmarks Placement in Aortic Annulus During Aortic Valve Replacement in the Era of Valve-In-Valve Transcatheter Aortic Implantation
    Baikoussis, Nikolaos G.
    Argiriou, Michalis
    Dedeilias, Panagiotis
    ANNALS OF THORACIC SURGERY, 2016, 102 (01): : 349 - 350
  • [45] Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients
    Elattar, Mustafa A.
    Vink, Leon W.
    van Mourik, Martijn S.
    Baan, Jan, Jr.
    van Bavel, Ed T.
    Planken, R. Nils
    Marquering, Henk A.
    PLOS ONE, 2017, 12 (09):
  • [46] Numerous patients fail the aortic annulus criteria in transcatheter aortic valve implantation - comparison of current devices
    John, D.
    Hausen, S.
    Latsios, G.
    Yuecel, S.
    Eberle, H. -C.
    Farazandeh, M.
    Gerckens, U.
    Grube, E.
    Naber, C. K.
    Bruder, O.
    EUROPEAN HEART JOURNAL, 2011, 32 : 904 - 904
  • [47] Impact of the method used for aortic annulus measurement on transcatheter aortic valve implantation results
    Sordi, M.
    Messika-Zeitoun, D.
    Himbert, D.
    Serfay, J. M.
    Chiampan, A.
    Touati, A.
    Brochet, E.
    Iung, B.
    Vahanian, A.
    EUROPEAN HEART JOURNAL, 2012, 33 : 581 - 581
  • [48] An uncommon complication following transcatheter aortic valve implantation: Contained aortic annulus rupture
    Bouabdallaoui, Nadia
    Macron, Laurent
    Durand, Eric
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 169 (01) : E1 - E2
  • [49] Aortic and right ventricular rupture in a patient after transcatheter aortic valve implantation; The direction of the calcification predicts aortic annulus rupture
    Iyisoy, Atila
    Ozturk, Cengiz
    Demirkol, Sait
    Celik, Turgay
    Aparci, Mustafa
    Demir, Mustafa
    Yildirim, Ali Osman
    Sahin, Mehmet Ali
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 193 : 49 - 52
  • [50] Aortic valve anatomy and outcomes after transcatheter aortic valve implantation in bicuspid aortic valves
    De Biase, Chiara
    Mastrokostopoulos, Antonios
    Philippart, Raphael
    Desroche, Louis Marie
    Blanco, Stephanie
    Rehal, Kamel
    Dumonteil, Nicolas
    Tchetche, Didier
    DATA IN BRIEF, 2018, 17 : 667 - 670