Risk evaluation of adverse aortic events in patients with non-circular aortic annulus after transcatheter aortic valve implantation: a numerical study

被引:4
|
作者
Wen, Jun [1 ]
Gao, Qi [2 ]
Chen, Jingnan [2 ]
Li, Xinya [2 ]
Zhang, Kaiyue [1 ]
He, Gang [1 ,3 ]
Dai, Min [4 ]
Song, Pan [4 ]
机构
[1] Southwest Univ Sci & Technol, Sch Comp Sci & Technol, Qinglong Rd 56, Mianyang 621010, Peoples R China
[2] Southwest Univ Sci & Technol, Inst Civil Engn & Architecture, Mianyang 621010, Peoples R China
[3] Mianyang Cent Hosp, NHC Key Lab Nucl Technol Med Transformat, Mianyang 621010, Peoples R China
[4] Mianyang Cent Hosp, Dept Cardiol, 12 Changjia Lane,Jingzhong St, Mianyang 621000, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Transcatheter aortic valve implantation; Hemodynamic; Annulus; Non-circular; Computational fluid dynamics; COMPUTATIONAL MODEL; FLUID-MECHANICS; MASS-TRANSFER; SHEAR-STRESS; FLOW; TRANSPORT; ENDOTHELIUM; SIMULATION; SYSTEMS; BYPASS;
D O I
10.1007/s10237-023-01725-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Transcatheter aortic valve implantation (TAVI) is a micro-invasive surgery used to treat patients with aortic stenosis (AS) efficiently. However, the uneven valve expansion can cause a non-circular annulus, which is one of the main factors leading to complications after TAVI. As a preliminary work, the main purpose of this study was to evaluate the risk of adverse aortic events in patients with a non-circular aortic annulus after TAVI. This study numerically investigated the distribution of four wall shear stress (WSS)-based indicators and three helicity-based indicators in eight patient-specific aortas with different annulus including circular, type I elliptical and type II elliptical shapes. Both elliptical annulus features can significantly enhance the intensity of the helicity (h2) in the ascending aorta (p < 0.001). However, for the type I elliptical annulus, the spiral flow structure was changed into low-velocity and disturbed flow pattern close to the inner side of the aortic arch. For the type II elliptical annulus, the spiral flow remained but became skewed in distribution. The elliptical annulus feature could increase the general level WSS-based indicators, especially in the ascending aorta. However, due to the disturbance of spiral flow or second helical flow in ascending aortas, areas with low TAWSS accompanied by high oscillatory shear index (OSI) and cross flow index (CFI) were observed in all the ascending aortas with non-circular annulus. The elliptical annulus feature can change the hemodynamic environment in the aortic arch, especially in the ascending aorta. Although both elliptical annulus features enhanced the strength of helicity, the uniform distribution of the helical flow was disturbed, especially in the ascending aorta, indicating the potential risk of adverse aortic events may increase. Therefore, for the patients without paravalvular leak but elliptical annulus shape after TAVI treatment, surgeons may be needed to consider further dilatation to make the non-circular annulus become circular.
引用
收藏
页码:1379 / 1394
页数:16
相关论文
共 50 条
  • [31] Contained Rupture of the Aortic Annulus After Transcatheter Aortic Valve Implantation: Uncommon Presentation of a Rare Complication
    Rodgers, Valerie
    Gobeil, Francois
    Noiseux, Nicolas
    Stevens, Louis-Mathieu
    Berube, Lyne
    Provost, Yves
    Masson, Jean-Bernard
    CANADIAN JOURNAL OF CARDIOLOGY, 2014, 30 (06) : 696.e5 - 696.e7
  • [32] Fractal dimension of the aortic annulus: a novel predictor of paravalvular leak after transcatheter aortic valve implantation
    Stachel, Georg
    Abdel-Wahab, Mohamed
    De Waha-Thiele, Suzanne
    Desch, Steffen
    Feistritzer, Hans-Josef
    Kitamura, Mitsunobu
    Farhan, Serdar
    Eitel, Ingo
    Kurz, Thomas
    Thiele, Holger
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2022, 38 (11): : 2469 - 2478
  • [33] Contained aortic annulus rupture with persisting false aneurysm after transfemoral transcatheter aortic valve implantation
    Stephanie Egenrieder
    Stephan Hill
    Maik Backes
    Matthias Vöhringer
    Udo Sechtem
    Clinical Research in Cardiology, 2014, 103 : 599 - 601
  • [34] Delayed Aortic Dissection after Transcatheter Aortic Valve Implantation
    Sahin, Sinan
    Korkmaz, Hatice Ayca Ata
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2023, 51 (08): : 577 - 579
  • [35] Delayed Aortic Dissection after Transcatheter Aortic Valve Implantation
    Al-Attar, Nawwar
    Himbert, Dominique
    Barbier, Francois
    Vahanian, Alec
    Nataf, Patrick
    JOURNAL OF HEART VALVE DISEASE, 2013, 22 (05): : 701 - 703
  • [36] Outcomes in patients with contained ruptures of the aortic annulus after transcatheter aortic valve implantation with balloon-expandable devices
    Breitbart, Philipp
    Minners, Jan
    Pache, Gregor
    Blanke, Philipp
    Reinoehl, Jochen
    Hansson, Nicolaj Christopher
    Norgaard, Bjarne L.
    Neumann, Franz-Josef
    Ruile, Philipp
    EUROINTERVENTION, 2017, 13 (11) : 1301 - 1303
  • [37] Aortic Complex Rupture After Transcatheter Aortic Valve Implantation
    Tsuru, Yasuo
    Miura, Mizuki
    Shirai, Shinichi
    Hayashi, Masaomi
    Taninobu, Kenji
    Takiguchi, Hiroshi
    Ito, Shinya
    Yano, Mariko
    Kawaguchi, Tomohiro
    Morinaga, Takashi
    Isotani, Akihiro
    Kakumoto, Shinichi
    Seo, Katsuhiro
    Arai, Yoshio
    Sakaguchi, Genichi
    Ando, Kenji
    INTERNATIONAL HEART JOURNAL, 2019, 60 (03) : 772 - 777
  • [38] Outcomes of Transcatheter Aortic Valve Replacement in Patients With Small Aortic Annulus
    Bashir, Hanad
    Hasan, Saad
    Caldwell, Austin
    Kereiakes, Dean
    Seshiah, Puvi
    Choo, Joseph
    Answini, Geoffrey
    Seshiah, Meghna
    Schmidt, Christan
    Garcia, Santiago
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B76 - B76
  • [39] Transcatheter aortic valve implantation for Chinese patients with bicuspid aortic valve
    Yu-guo Weng
    Journal of Zhejiang University-SCIENCE B, 2015, 16 : 327 - 328
  • [40] Transcatheter Aortic Valve Implantation in Patients With Bicuspid Aortic Valve Stenosis
    Wijesinghe, Namal
    Ye, Jian
    Rodes-Cabau, Josep
    Cheung, Anson
    Velianou, James L.
    Natarajan, Madhu K.
    Dumont, Eric
    Nietlispach, Fabian
    Gurvitch, Ronen
    Wood, David A.
    Tay, Edgar
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) : 1122 - 1125