Paediatric effective radiation doses during brain computed tomography angiography procedure

被引:2
|
作者
Salah, H. [1 ,2 ]
Rabbaa, Mohammad [3 ]
Abuljoud, Mohammad [3 ]
Babikir, E. [4 ]
Alkhorayef, M. [5 ]
Tamam, N. [6 ]
Tahir, Dahlang [7 ]
Sulieman, A. [8 ]
Bradley, D. A. [9 ,10 ]
机构
[1] INAYA Med Collage, Nucl Med Dept, Riyadh, Saudi Arabia
[2] Sudan Univ Sci & Technol, Coll Med Radiol Sci, Khartoum, Sudan
[3] Riyadh Care Hosp, Radiol Dept, Riyadh, Saudi Arabia
[4] Univ Bahrain, Coll Hlth & Sport Sci, Radiol Technol Program, Sakhir Campus,POB 32038, Zallaq, Bahrain
[5] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 10219, Riyadh 11433, Saudi Arabia
[6] Princess Nourah bint Abdulrahman Univ, Coll Sci, Dept Phys, POB 84428, Riyadh 11671, Saudi Arabia
[7] Hasanuddin Univ, Dept Phys, Makassar 90245, Indonesia
[8] Prince Sattam bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, POB 422, Alkharj 11942, Saudi Arabia
[9] Univ Surrey, Ctr Nucl & Radiat Phys, Dept Phys, Guildford, England
[10] Sunway Univ, Ctr Appl Phys & Radiat Technol, Sch Engn & Technol, Bandar Sunway 47500, Selangor, Malaysia
关键词
CT brain; Diagnostic radiology; Paediatirc imaging; Radiation dosimetry; DLP; Effective dose; DIAGNOSTIC REFERENCE LEVELS; CT; REDUCTION; CHILDREN; QUALITY;
D O I
10.1016/j.apradiso.2022.110610
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In comparison to adults and paediatric are more sensitive to ionizing radiation exposure. Computed tomography (CT) is now the dominant source of medical radiologic tests for patients, accounting for more than 70% of total doses to the general public. Paediatric CT brain scans (with and without contrast) are routinely performed for a variety of clinical reasons. As a result, this parameter must be calculated in order to determine relative radiation risk. The goal of this study is to assess the radiation risk to children during CT brain diagnostic procedures. Three hundred fifty three child patients' radiation risk doses were assessed over the course of a year. The mean and ranged of the children's radiation doses were 40.6 +/- 8.8 (27.8-45.8) CTDIvol (mGy) and 850 +/- 230 (568.1-1126.4) DLP (mGy.cm) for the brain with contrast medium. For CT brain without contrast, the patients' doses were 40.9 +/- 9.4 (14.27-64.07) CTDIvol (mGy), and 866.1 +/- 289.3 (203.6-2484.9) DLP (mGy.cm). The characteristics related to the radiation dose were retrieved from the scan protocol generated by the CT system by the participating physicians after each procedure. Furthermore, optimizing the CT acquisition parameter is critical for increasing the benefit while lowering the procedure's radiogenic risk. The patients' radiation dose is comparable with the most previously published studies and international diagnostic reference levels (DRLs). Radiation dose optimization is recommended due to high sensitivity of the paediatric patients to ionizing radiation.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Radiation Protection in Paediatric Computed Tomography Revisited
    Liu, D.
    Khong, P. L.
    HONG KONG JOURNAL OF RADIOLOGY, 2016, 19 (03): : 166 - 169
  • [22] COMPUTED-TOMOGRAPHY AND RADIATION-DOSES
    MOLYNEUX, AJ
    LANCET, 1991, 337 (8750): : 1164 - 1164
  • [23] Radiation Doses from Computed tomography in Iraq
    Al-Kinani, Athab
    Saddam, Ahmad
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2014, 47 (01): : 114 - 124
  • [24] Effective radiation dose of three diagnostic tests in cardiology: Single photon emission computed tomography, invasive coronary angiography and cardiac computed tomography angiography
    Goncalves, Pedro de Araujo
    Sousa, Pedro Jeronimo
    Cale, Rita
    Marques, Hugo
    dos Santos, Miguel Borges
    Dias, Andre
    Dores, Helder
    Carvalho, Maria Salome
    Ventosa, Antonio
    Martins, Teresa
    Teles, Rui Campante
    Almeida, Manuel
    Mendes, Miguel
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2013, 32 (12) : 981 - 986
  • [25] A survey of the pediatric radiation doses during multiphase abdominal computed tomography examinations
    Sulieman, A.
    Adam, H.
    Tamam, N.
    Alkhorayef, M.
    Alhailiy, A.
    Alghamdi, S.
    Elnour, A.
    Alomair, O.
    Alashban, Y.
    Khandaker, M. U.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [26] Characterisation of computed tomography angiography findings in paediatric patients with heterotaxy
    Ugas Charcape, Carlos F.
    Alpaca Rodriguez, Larry R.
    Matos Rojas, Irma A.
    Lazarte Rantes, Claudia, I
    Valdez Quintana, Melissa
    Katekaru Tokeshi, Doris A.
    Epelman, Monica
    PEDIATRIC RADIOLOGY, 2019, 49 (09) : 1142 - 1151
  • [27] Characterisation of computed tomography angiography findings in paediatric patients with heterotaxy
    Carlos F. Ugas Charcape
    Larry R. Alpaca Rodriguez
    Irma A. Matos Rojas
    Claudia I. Lazarte Rantes
    Melissa Valdez Quintana
    Doris A. Katekaru Tokeshi
    Monica Epelman
    Pediatric Radiology, 2019, 49 : 1142 - 1151
  • [28] Effective ionizing radiation dose exposure during coronary computed tomography and conventional angiography combined with coronary physiology measurements
    Ntalianis, A.
    De Booj, M.
    Ntarladimas, Y.
    Trana, C.
    Vanhoenacker, P.
    De Backer, C.
    Barbato, E.
    Van Mieghem, C.
    Wijns, W.
    De Bruyne, B.
    EUROPEAN HEART JOURNAL, 2012, 33 : 1014 - 1014
  • [29] The effect of contrast material on radiation dose during computed tomography pulmonary angiography
    Karami, Haleh
    Miri-Hakimabad, Hashem
    Hoseinian-Azghadi, Elie
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (03): : 211 - 221
  • [30] ESTIMATION OF PATIENT RADIATION DOSES FROM MULTI-DETECTOR COMPUTED TOMOGRAPHY ANGIOGRAPHY PROCEDURES IN TANZANIA
    Ngaile, J. E.
    Msaki, P. K.
    Suleiman, S. A.
    Chuma, F. M.
    Muhogora, W. E.
    Jusabani, A. M.
    RADIATION PROTECTION DOSIMETRY, 2021, 197 (02) : 63 - 77