Paediatric effective radiation doses during brain computed tomography angiography procedure

被引:2
|
作者
Salah, H. [1 ,2 ]
Rabbaa, Mohammad [3 ]
Abuljoud, Mohammad [3 ]
Babikir, E. [4 ]
Alkhorayef, M. [5 ]
Tamam, N. [6 ]
Tahir, Dahlang [7 ]
Sulieman, A. [8 ]
Bradley, D. A. [9 ,10 ]
机构
[1] INAYA Med Collage, Nucl Med Dept, Riyadh, Saudi Arabia
[2] Sudan Univ Sci & Technol, Coll Med Radiol Sci, Khartoum, Sudan
[3] Riyadh Care Hosp, Radiol Dept, Riyadh, Saudi Arabia
[4] Univ Bahrain, Coll Hlth & Sport Sci, Radiol Technol Program, Sakhir Campus,POB 32038, Zallaq, Bahrain
[5] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 10219, Riyadh 11433, Saudi Arabia
[6] Princess Nourah bint Abdulrahman Univ, Coll Sci, Dept Phys, POB 84428, Riyadh 11671, Saudi Arabia
[7] Hasanuddin Univ, Dept Phys, Makassar 90245, Indonesia
[8] Prince Sattam bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, POB 422, Alkharj 11942, Saudi Arabia
[9] Univ Surrey, Ctr Nucl & Radiat Phys, Dept Phys, Guildford, England
[10] Sunway Univ, Ctr Appl Phys & Radiat Technol, Sch Engn & Technol, Bandar Sunway 47500, Selangor, Malaysia
关键词
CT brain; Diagnostic radiology; Paediatirc imaging; Radiation dosimetry; DLP; Effective dose; DIAGNOSTIC REFERENCE LEVELS; CT; REDUCTION; CHILDREN; QUALITY;
D O I
10.1016/j.apradiso.2022.110610
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In comparison to adults and paediatric are more sensitive to ionizing radiation exposure. Computed tomography (CT) is now the dominant source of medical radiologic tests for patients, accounting for more than 70% of total doses to the general public. Paediatric CT brain scans (with and without contrast) are routinely performed for a variety of clinical reasons. As a result, this parameter must be calculated in order to determine relative radiation risk. The goal of this study is to assess the radiation risk to children during CT brain diagnostic procedures. Three hundred fifty three child patients' radiation risk doses were assessed over the course of a year. The mean and ranged of the children's radiation doses were 40.6 +/- 8.8 (27.8-45.8) CTDIvol (mGy) and 850 +/- 230 (568.1-1126.4) DLP (mGy.cm) for the brain with contrast medium. For CT brain without contrast, the patients' doses were 40.9 +/- 9.4 (14.27-64.07) CTDIvol (mGy), and 866.1 +/- 289.3 (203.6-2484.9) DLP (mGy.cm). The characteristics related to the radiation dose were retrieved from the scan protocol generated by the CT system by the participating physicians after each procedure. Furthermore, optimizing the CT acquisition parameter is critical for increasing the benefit while lowering the procedure's radiogenic risk. The patients' radiation dose is comparable with the most previously published studies and international diagnostic reference levels (DRLs). Radiation dose optimization is recommended due to high sensitivity of the paediatric patients to ionizing radiation.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain
    Netwong, Y.
    Krisanachinda, A.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [12] Radiation Doses in Cardiovascular Computed Tomography
    Kedzierski, Bartlomiej
    Macek, Piotr
    Dziadkowiec-Macek, Barbara
    Truszkiewicz, Krystian
    Poreba, Rafal
    Gac, Pawel
    LIFE-BASEL, 2023, 13 (04):
  • [13] Comparison of Radiation Doses of Computed Tomography Brain and Pulmonary Angiography with International Commission on Radiological Protection Guidelines: A Descriptive Study
    Fidha, A. F.
    Alphy, George Arattu
    Amita, Dabholkar Digambar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (05) : TC1 - TC4
  • [14] Comparison of Effective Doses between Computed Tomography Cardiac Angiography and Conventional Angiography at Pantai Hospital, Kuala Lumpur
    Mohamed, Faizal
    Moin, F. H. A.
    2012 NATIONAL PHYSICS CONFERENCE (PERFIK 2012), 2013, 1528 : 423 - 427
  • [15] Chest Circumference as a Predictive Parameter of Computed Tomography Coronary Angiography Radiation Doses from Dual-Source Computed Tomography
    Sagsoz, M. Erdem
    Bayraktutan, Ummugulsum
    Ogul, Hayri
    Kantarci, Mecit
    EURASIAN JOURNAL OF MEDICINE, 2013, 45 (01): : 43 - 46
  • [16] Radiation doses in computed tomography - The increasing doses of radiation need to be controlled
    Rehani, MM
    Berry, M
    BRITISH MEDICAL JOURNAL, 2000, 320 (7235): : 593 - 594
  • [17] Radiation doses to neonates during X ray computed tomography examinations
    Akahane, K
    Hashimoto, M
    Hada, M
    Takano, Y
    Ono, K
    Kai, M
    Kusama, T
    RADIATION PROTECTION DOSIMETRY, 2003, 103 (01) : 41 - 45
  • [18] A closer look at the utilized radiation doses during computed tomography pulmonary angiography (CTPA) for COVID-19 patients
    Abuzaid, Mohamed
    Elshami, Wiam
    Cavli, Baris
    Ozturk, Ceren
    ALMisned, Ghada
    Tekin, H. O.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 211
  • [19] Energy imparted and effective doses in computed tomography
    Atherton, JV
    Huda, W
    MEDICAL PHYSICS, 1996, 23 (05) : 735 - 741
  • [20] Assessment of computed tomography radiation doses for paediatric head and chest examinations using paediatric phantoms of three different ages
    Saeed, M. K.
    Almalki, Y.