Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT

被引:3
|
作者
Layer, Yannik C. [1 ]
Mesropyan, Narine [1 ]
Kupczyk, Patrick A. [1 ]
Luetkens, Julian A. [1 ]
Isaak, Alexander [1 ]
Dell, Tatjana [1 ]
Ernst, Benjamin P. [2 ]
Attenberger, Ulrike I. [1 ]
Kuetting, Daniel [1 ]
机构
[1] Univ Hosp Bonn, Dept Diagnost & Intervent Radiol, Venusberg Campus 1, D-53127 Bonn, Germany
[2] Univ Hosp Bonn, Dept Otorhinolaryngol, Venusberg Campus 1, D-53127 Bonn, Germany
关键词
DUAL-ENERGY CT; METAL ARTIFACTS; RECONSTRUCTION; HEAD; QUALITY; PHYSICS;
D O I
10.1038/s41598-023-50926-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (>= 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100-190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1-3) and 1 (1-3); e.g. VMI130 keV 2 (1-5); p < 0.0001 and 2 (1-4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 +/- 98.16; VMI130 keV: - 0.55 +/- 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Photon-counting Detector CT with Deep Learning Noise Reduction to Detect Multiple Myeloma
    Baffour, Francis I.
    Huber, Nathan R.
    Ferrero, Andrea
    Rajendran, Kishore
    Glazebrook, Katrina N.
    Larson, Nicholas B.
    Kumar, Shaji
    Cook, Joselle M.
    Leng, Shuai
    Shanblatt, Elisabeth R.
    McCollough, Cynthia H.
    Fletcher, Joel G.
    RADIOLOGY, 2023, 306 (01) : 229 - 236
  • [42] Virtual monochromatic imaging with projection-based material decomposition algorithm for metal artifacts reduction in photon-counting detector computed tomography
    Chang, Chia-Hao
    Wu, Hsiang-Ning
    Hsu, Ching-Han
    Lin, Hsin-Hon
    PLOS ONE, 2023, 18 (03):
  • [43] Combining virtual monoenergetic imaging and iterative metal artifact reduction in first-generation photon-counting computed tomography of patients with dental implants
    Patzer, Theresa Sophie
    Kunz, Andreas Steven
    Huflage, Henner
    Gruschwitz, Philipp
    Pannenbecker, Pauline
    Afat, Saif
    Herrmann, Judith
    Petritsch, Bernhard
    Bley, Thorsten Alexander
    Grunz, Jan-Peter
    EUROPEAN RADIOLOGY, 2023, 33 (11) : 7818 - 7829
  • [44] Triple-energy virtual monochromatic imaging with a photon-counting detector for reducing metal artifacts in half-beam dental computed tomography
    Lee, M.
    Lee, H.
    Lee, S.
    Kim, W.
    Lim, Y.
    Choa, H.
    Cha, B.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (11):
  • [45] Using Virtual Monoenergetic Images and Electron Density (Rho) Images from Photon-Counting CT (PCCT) for Radiation Therapy (RT) Dose Calculation: A Comparison Study
    Wu, X.
    Wohlfahrt, P.
    Shah, J.
    Wu, Q.
    Wu, Q. J. J.
    Sheng, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : S161 - S161
  • [46] Metal artifact reduction in patients with total hip replacements: evaluation of clinical photon counting CT using virtual monoenergetic images
    Schreck, Julian
    Laukamp, Kai Roman
    Niehoff, Julius Henning
    Michael, Arwed Elias
    Boriesosdick, Jan
    Woeltjen, Matthias Michael
    Kroeger, Jan Robert
    Reimer, Robert P. P.
    Grunz, Jan-Peter
    Borggrefe, Jan
    Lennartz, Simon
    EUROPEAN RADIOLOGY, 2023, 33 (12) : 9286 - 9295
  • [47] Metal artifact reduction in patients with total hip replacements: evaluation of clinical photon counting CT using virtual monoenergetic images
    Julian Schreck
    Kai Roman Laukamp
    Julius Henning Niehoff
    Arwed Elias Michael
    Jan Boriesosdick
    Matthias Michael Wöltjen
    Jan Robert Kröger
    Robert P. Reimer
    Jan-Peter Grunz
    Jan Borggrefe
    Simon Lennartz
    European Radiology, 2023, 33 : 9286 - 9295
  • [48] Synthetic hematocrit from virtual non-contrast images for myocardial extracellular volume evaluation with photon-counting detector CT
    Mergen, Victor
    Ehrbar, Nicolas
    Moser, Lukas J.
    Harmes, Johannes C.
    Manka, Robert
    Alkadhi, Hatem
    Eberhard, Matthias
    EUROPEAN RADIOLOGY, 2024, 34 (12) : 7845 - 7855
  • [49] Performance of virtual non-contrast images generated on clinical photon-counting detector CT for emphysema quantification: proof of concept
    Jungblut, Lisa
    Sartoretti, Thomas
    Kronenberg, Daniel
    Mergen, Victor
    Euler, Andre
    Schmidt, Bernhard
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Martini, Katharina
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1135):
  • [50] Editorial Comment: Better Images of the Pelvis With Less Dose Using Photon-Counting Detector CT
    Roth, Trenton D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (01)