Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT

被引:3
|
作者
Layer, Yannik C. [1 ]
Mesropyan, Narine [1 ]
Kupczyk, Patrick A. [1 ]
Luetkens, Julian A. [1 ]
Isaak, Alexander [1 ]
Dell, Tatjana [1 ]
Ernst, Benjamin P. [2 ]
Attenberger, Ulrike I. [1 ]
Kuetting, Daniel [1 ]
机构
[1] Univ Hosp Bonn, Dept Diagnost & Intervent Radiol, Venusberg Campus 1, D-53127 Bonn, Germany
[2] Univ Hosp Bonn, Dept Otorhinolaryngol, Venusberg Campus 1, D-53127 Bonn, Germany
关键词
DUAL-ENERGY CT; METAL ARTIFACTS; RECONSTRUCTION; HEAD; QUALITY; PHYSICS;
D O I
10.1038/s41598-023-50926-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (>= 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100-190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1-3) and 1 (1-3); e.g. VMI130 keV 2 (1-5); p < 0.0001 and 2 (1-4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 +/- 98.16; VMI130 keV: - 0.55 +/- 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Photon-counting detector CT-based virtual monoenergetic reconstructions: repeatability and reproducibility of radiomics features of an organic phantom and human myocardium
    Elias V. Wolf
    Lukas Müller
    U. Joseph Schoepf
    Nicola Fink
    Joseph P. Griffith
    Emese Zsarnoczay
    Dhiraj Baruah
    Pal Suranyi
    Ismael M. Kabakus
    Moritz C. Halfmann
    Tilman Emrich
    Akos Varga-Szemes
    Jim O‘Doherty
    European Radiology Experimental, 7
  • [32] Optimizing Arterial Vessel Contrast in Portal Venous Phase with Virtual Monoenergetic Images from Photon-Counting Detector CT Scans of the Abdomen-First Clinical Experiences
    Dillinger, Daniel
    Overhoff, Daniel
    Ayx, Isabelle
    Kaatsch, Hanns L.
    Hagen, Achim
    Schoenberg, Stefan O.
    Waldeck, Stephan
    DIAGNOSTICS, 2024, 14 (06)
  • [33] Development of virtual monochromatic imaging technique with spectral CT based on a photon-counting detector
    Lee, Seungwan
    Kang, Sooncheol
    Eom, Jisoo
    Kim, Burnyoung
    Lee, Duhgoon
    Lee, Chang-Lae
    Jung, Jinwook
    Jang, Wooyoung
    Choi, Yuna
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [34] Metal Artifact Reduction in Photon-Counting Detector CT Quantitative Evaluation of Artifact Reduction Techniques
    Skornitzke, Stephan
    Mergen, Victor
    Biederer, Juergen
    Alkadhi, Hatem
    Do, Thuy D.
    Stiller, Wolfram
    Frauenfelder, Thomas
    Kauczor, Hans-Ulrich
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2024, 59 (06) : 442 - 449
  • [35] Optimisation of virtual monoenergetic reconstructions for the diagnosis of pulmonary embolism using photon-counting detector computed tomography angiography
    Chamberlin, Jordan H.
    Toth, Adrienn
    Hinen, Shaun
    O'Doherty, Jim
    Baruah, Dhiraj
    Maisuria, Dhruw
    Mcguire, Aaron
    Knight, Heather
    Schoepf, U. Joseph
    Munden, Reginald F.
    Kabakus, Ismail M.
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e63 - e69
  • [36] Photon-counting detector computed tomography: iodine density versus virtual monoenergetic imaging of pancreatic ductal adenocarcinoma
    Alagic, Zlatan
    Duran, Carlos Valls
    Suzuki, Chikako
    Halldorsson, Kolbeinn
    Svensson-Marcial, Anders
    Saeter, Rebecca
    Koskinen, Seppo K.
    ABDOMINAL RADIOLOGY, 2025, 50 (04) : 1720 - 1730
  • [37] The first mobile photon-counting detector CT: the human images and technical performance study
    Park, Su-Jin
    Park, Junyoung
    Kim, Doil
    Lee, Duhgoon
    Lee, Chang-Lae
    Bechwati, Ibrahim
    Wu, Dufan
    Gupta, Rajiv
    Jung, Jinwook
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (09):
  • [38] Metal artifacts from sternal wires: evaluation of virtual monoenergetic images from spectral-detector CT for artifact reduction
    Laukamp, Kai Roman
    Hokamp, Nils Grosse
    Alabar, Omar
    Obmann, Verena Carola
    Lennartz, Simon
    Zopfs, David
    Gilkeson, Robert
    Ramaiya, Nikhil
    Gupta, Amit
    CLINICAL IMAGING, 2020, 60 (02) : 249 - 256
  • [39] Photon-Counting Detector CT for Liver Lesion Detection-Optimal Virtual Monoenergetic Energy for Different Simulated Patient Sizes and Radiation Doses
    Racine, Damien
    Mergen, Victor
    Viry, Anais
    Frauenfelder, Thomas
    Alkadhi, Hatem
    Vitzthum, Veronika
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2024, 59 (08) : 554 - 560
  • [40] Photon-counting detector coronary CT angiography: Defining the optimal monoenergetic level for grading of calcified coronary stenosis
    Sartoretti, Thomas
    Moser, Lukas J.
    Civaia, Filippo
    Rossi, Philippe
    Candreva, Alessandro
    Manka, Robert
    Eberhard, Matthias
    Alkadhi, Hatem
    Mergen, Victor
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2024, 18 (06) : 616 - 617