Photon-counting Detector CT with Deep Learning Noise Reduction to Detect Multiple Myeloma

被引:40
|
作者
Baffour, Francis I. [1 ]
Huber, Nathan R. [1 ]
Ferrero, Andrea [1 ]
Rajendran, Kishore [1 ]
Glazebrook, Katrina N. [1 ]
Larson, Nicholas B. [2 ]
Kumar, Shaji [3 ]
Cook, Joselle M. [3 ]
Leng, Shuai [1 ]
Shanblatt, Elisabeth R. [4 ]
McCollough, Cynthia H. [1 ]
Fletcher, Joel G. [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Div Biomed Stat & Informat, Dept Quantitat Hlth Sci, 200 First St SW, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Med, Div Hematol, 200 First St SW, Rochester, MN 55905 USA
[4] Siemens Med Solut USA, Malvern, PA USA
关键词
CRITERIA;
D O I
10.1148/radiol.220311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Photon-counting detector (PCD) CT and deep learning noise reduction may improve spatial resolution at lower radiation doses compared with energy-integrating detector (EID) CT.Purpose: To demonstrate the diagnostic impact of improved spatial resolution in whole-body low-dose CT scans for viewing multiple myeloma by using PCD CT with deep learning denoising compared with conventional EID CT. Materials and Methods: Between April and July 2021, adult participants who underwent a whole-body EID CT scan were prospectively enrolled and scanned with a PCD CT system in ultra-high-resolution mode at matched radiation dose (8 mSv for an average adult) at an academic medical center. EID CT and PCD CT images were reconstructed with Br44 and Br64 kernels at 2-mm section thick-ness. PCD CT images were also reconstructed with Br44 and Br76 kernels at 0.6-mm section thickness. The thinner PCD CT imag-es were denoised by using a convolutional neural network. Image quality was objectively quantified in two phantoms and a randomly selected subset of participants (10 participants; median age, 63.5 years; five men). Two radiologists scored PCD CT images relative to EID CT by using a five-point Likert scale to detect findings reflecting multiple myeloma. The scoring for the matched reconstruction series was blinded to scanner type. Reader-averaged scores were tested with the null hypothesis of equivalent visualization between EID and PCD. Results: Twenty-seven participants (median age, 68 years; IQR, 61-72 years; 16 men) were included. The blinded assessment of 2-mm images demonstrated improvement in viewing lytic lesions, intramedullary lesions, fatty metamorphosis, and pathologic fractures for PCD CT versus EID CT (P < .05 for all comparisons). The 0.6-mm PCD CT images with convolutional neural network denoising also demonstrated improvement in viewing all four pathologic abnormalities and detected one or more lytic lesions in 21 of 27 partici-pants compared with the 2-mm EID CT images (P < .001). Conclusion: Ultra-high-resolution photon-counting detector CT improved the visibility of multiple myeloma lesions relative to energy-integrating detector CT.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 50 条
  • [1] MSK - Myeloma Diagnostics with Photon-Counting Detector CT
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (11): : 976 - +
  • [2] Photon-Counting Detector CT
    Marth, Adrian A.
    Goller, Sophia S.
    Kajdi, Georg W.
    Marcus, Roy P.
    Sutter, Reto
    INVESTIGATIVE RADIOLOGY, 2024, 59 (08) : 545 - 553
  • [3] Photon-Counting CT Binning and Electronic Noise Reduction
    Wininger, Kevin L.
    RADIOLOGIC TECHNOLOGY, 2024, 95 (04) : 276 - 279
  • [4] Prospective Multireader Evaluation of Photon-counting CT for Multiple Myeloma Screening
    Schwartz, Fides R.
    Vinson, Emily N.
    Spritzer, Charles E.
    Colglazier, Roy
    Samei, Ehsan
    French, Robert J.
    Said, Nicholas
    Waldman, Leah
    McCrum, Erin
    RADIOLOGY-IMAGING CANCER, 2022, 4 (06):
  • [5] The technical development of photon-counting detector CT
    Cynthia H. McCollough
    Kishore Rajendran
    Shuai Leng
    Lifeng Yu
    Joel G. Fletcher
    Karl Stierstorfer
    Thomas G. Flohr
    European Radiology, 2023, 33 : 5321 - 5330
  • [6] The Future Arrived Photon-Counting Detector CT
    Alkadhi, Hatem
    Runge, Val
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 439 - 440
  • [7] The technical development of photon-counting detector CT
    McCollough, Cynthia H.
    Rajendran, Kishore
    Leng, Shuai
    Yu, Lifeng
    Fletcher, Joel G.
    Stierstorfer, Karl
    Flohr, Thomas G.
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5321 - 5330
  • [8] AJR Forum on Photon-Counting Detector CT
    Dane, Bari
    Amrhein, Timothy J.
    Kay, Fernando
    Schwartz, Fides R.
    Toia, Giuseppe V.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (06)
  • [9] Advanced Neuroimaging With Photon-Counting Detector CT
    Abel, Frederik
    Schubert, Tilman
    Winklhofer, Sebastian
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 472 - 481
  • [10] Pediatric Applications of Photon-Counting Detector CT
    Cao, Joseph
    Bache, Steve
    Schwartz, Fides R.
    Frush, Donald
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (04) : 580 - 589