Photon-counting Detector CT with Deep Learning Noise Reduction to Detect Multiple Myeloma

被引:40
|
作者
Baffour, Francis I. [1 ]
Huber, Nathan R. [1 ]
Ferrero, Andrea [1 ]
Rajendran, Kishore [1 ]
Glazebrook, Katrina N. [1 ]
Larson, Nicholas B. [2 ]
Kumar, Shaji [3 ]
Cook, Joselle M. [3 ]
Leng, Shuai [1 ]
Shanblatt, Elisabeth R. [4 ]
McCollough, Cynthia H. [1 ]
Fletcher, Joel G. [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Div Biomed Stat & Informat, Dept Quantitat Hlth Sci, 200 First St SW, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Med, Div Hematol, 200 First St SW, Rochester, MN 55905 USA
[4] Siemens Med Solut USA, Malvern, PA USA
关键词
CRITERIA;
D O I
10.1148/radiol.220311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Photon-counting detector (PCD) CT and deep learning noise reduction may improve spatial resolution at lower radiation doses compared with energy-integrating detector (EID) CT.Purpose: To demonstrate the diagnostic impact of improved spatial resolution in whole-body low-dose CT scans for viewing multiple myeloma by using PCD CT with deep learning denoising compared with conventional EID CT. Materials and Methods: Between April and July 2021, adult participants who underwent a whole-body EID CT scan were prospectively enrolled and scanned with a PCD CT system in ultra-high-resolution mode at matched radiation dose (8 mSv for an average adult) at an academic medical center. EID CT and PCD CT images were reconstructed with Br44 and Br64 kernels at 2-mm section thick-ness. PCD CT images were also reconstructed with Br44 and Br76 kernels at 0.6-mm section thickness. The thinner PCD CT imag-es were denoised by using a convolutional neural network. Image quality was objectively quantified in two phantoms and a randomly selected subset of participants (10 participants; median age, 63.5 years; five men). Two radiologists scored PCD CT images relative to EID CT by using a five-point Likert scale to detect findings reflecting multiple myeloma. The scoring for the matched reconstruction series was blinded to scanner type. Reader-averaged scores were tested with the null hypothesis of equivalent visualization between EID and PCD. Results: Twenty-seven participants (median age, 68 years; IQR, 61-72 years; 16 men) were included. The blinded assessment of 2-mm images demonstrated improvement in viewing lytic lesions, intramedullary lesions, fatty metamorphosis, and pathologic fractures for PCD CT versus EID CT (P < .05 for all comparisons). The 0.6-mm PCD CT images with convolutional neural network denoising also demonstrated improvement in viewing all four pathologic abnormalities and detected one or more lytic lesions in 21 of 27 partici-pants compared with the 2-mm EID CT images (P < .001). Conclusion: Ultra-high-resolution photon-counting detector CT improved the visibility of multiple myeloma lesions relative to energy-integrating detector CT.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 50 条
  • [41] Photon-Counting Detector CT for Musculoskeletal Imaging: A Clinical Perspective
    Baffour, Francis I.
    Glazebrook, Katrina N.
    Ferrero, Andrea
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    Rajendran, Kishore
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (04) : 551 - 560
  • [42] Quality Control of Photon-Counting Detector CT: Tips and Caveats
    Ahmed, Z.
    Ren, L.
    Vrieze, T.
    Rajendran, K.
    Ferrero, A.
    Favazza, C.
    Yu, L.
    Bruesewitz, M.
    McCollough, C.
    Leng, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E593 - E594
  • [43] Basic principles and clinical potential of photon-counting detector CT
    Thomas Flohr
    Stefan Ulzheimer
    Martin Petersilka
    Bernhard Schmidt
    Chinese Journal of Academic Radiology, 2020, 3 : 19 - 34
  • [44] Improved noise reduction in photon-counting detector CT using prior knowledge-aware iterative denoising neural network
    Chang, Shaojie
    Marsh Jr, Jeffrey F.
    Koons, Emily K.
    Gong, Hao
    Mccollough, Cynthia H.
    Leng, Shuai
    JOURNAL OF MEDICAL IMAGING, 2024, 11
  • [45] Pie-Net: Prior-information-enabled deep learning noise reduction for coronary CT angiography acquired with a photon counting detector CT
    Chang, Shaojie
    Huber, Nathan R.
    Marsh, Jeffrey F.
    Koons, Emily K.
    Gong, Hao
    Yu, Lifeng
    McCollough, Cynthia H.
    Leng, Shuai
    MEDICAL PHYSICS, 2023, 50 (10) : 6283 - 6295
  • [46] Photon-Counting Detector CT: Potential for 75% Reduction in Contrast Medium Amount: A Phantom Study
    Higaki, Fumiyo
    Morimitsu, Yusuke
    Iguchi, Toshihiro
    Saito, Hayato
    Takaki, Haruhiko
    Nakagoshi, Ayako
    Wada, Maki
    Uka, Mayu
    Akagi, Noriaki
    Mitsuhashi, Toshiharu
    Matsui, Yusuke
    Hiraki, Takao
    ACTA MEDICA OKAYAMA, 2024, 78 (02) : 135 - 142
  • [47] Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT
    Cundari, Giulia
    Deilmann, Philipp
    Mergen, Victor
    Ciric, Kristina
    Eberhard, Matthias
    Jungblut, Lisa
    Alkadhi, Hatem
    Higashigaito, Kai
    ACADEMIC RADIOLOGY, 2024, 31 (01) : 212 - 220
  • [48] Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma
    Rau, Alexander
    Neubauer, Jakob
    Taleb, Laetitia
    Stein, Thomas
    Schuermann, Till
    Rau, Stephan
    Faby, Sebastian
    Wenger, Sina
    Engelhardt, Monika
    Bamberg, Fabian
    Weiss, Jakob
    KOREAN JOURNAL OF RADIOLOGY, 2023, 24 (10) : 1006 - 1016
  • [49] Potential of photon-counting detector CT technology for contrast medium reduction in portal venous phase thoracoabdominal CT
    Popp, Daniel
    Siedlecki, Martin
    Friedrich, Lena
    Haerting, Mark
    Scheurig-Muenkler, Christian
    Schwarz, Florian
    Kroencke, Thomas
    Bette, Stefanie
    Decker, Josua A.
    EUROPEAN RADIOLOGY, 2025,
  • [50] Editorial Comment: Photon-Counting Detector CT-A New Era in CT
    Hackenbroch, Carsten
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (04) : 561 - 561