Refined scan protocol for the evaluation of pulmonary perfusion standardized image quality and reduced radiation dose in dynamic chest radiography

被引:1
|
作者
Takakura, Kenta [1 ]
Yamasaki, Yuzo [2 ]
Kuramoto, Taku [3 ]
Yoshidome, Satoshi [1 ]
Hida, Tomoyuki [4 ]
Kamitani, Takeshi [2 ]
Yoshikawa, Hideki [1 ]
Kato, Toyoyuki [1 ]
Ishigami, Kousei [2 ]
机构
[1] Kyushu Univ Hosp, Dept Med Technol, Div Radiol, Fukuoka, Japan
[2] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, 3-1-1 Maidash,Higashi Ku, Fukuoka 8128582, Japan
[3] Kobe Tokiwa Univ, Fac Hlth Sci, Dept Radiol Technol, Kobe, Japan
[4] Onga Nakama Med Assoc Onga Hosp, Dept Radiol, Fukuoka, Japan
来源
基金
日本学术振兴会;
关键词
body mass index; dynamic chest radiography; pulmonary perfusion; scan protocol; OPTIMIZATION; VENTILATION;
D O I
10.1002/acm2.14222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Dynamic chest radiography (DCR) is a novel imaging technique used to noninvasively evaluate pulmonary perfusion. However, the standard DCR protocol, which is roughly adapted to the patient's body size, occasionally causes over- or underexposure, which could influence clinical evaluation. Therefore, we proposed a refined protocol by increasing the number of patient body mass index (BMI) categories from three to seven groups and verified its usefulness by comparing the image sensitivity indicators (S-values) and entrance surface doses (ESDs) of the conventional protocol with those of our refined protocol.Methods: This retrospective observational study included 388 datasets (standing position, 224; supine position, 164) for the conventional protocol (December 2019-April 2021) and 336 datasets (standing position, 233; supine position, 103) for the refined protocol (June-November 2021). The conventional protocol (BMI-3 protocol) divided the patients into three BMI groups (BMI < 17, 17 <= BMI < 25, and BMI >= 25 kg/m(2)), whereas the refined protocol (BMI-7 protocol) divided the patients into seven BMI groups (BMI < 17, 17 <= BMI < 20, 20 <= BMI < 23, 23 <= BMI < 26, 26 <= BMI < 29, 29 <= BMI < 32, and BMI >= 32 kg/m(2)). The coefficients of variation (CVs) for the S-values and ESDs acquired using the two protocols were compared.Results: The CVs of the S-values in the BMI-7 protocol group were significantly lower than those in the BMI-3 protocol group for the standing (28.8% vs. 16.7%; p < 0.01) and supine (24.5% vs. 17.7%; p < 0.01) positions. The ESDs of patients scanned using the BMI-7 protocol were significantly lower than those scanned using the BMI-3 protocol in the standing (1.3 vs. 1.1 mGy; p < 0.01) and supine positions (2.5 vs. 1.6 mGy; p < 0.01), although the mean BMI of the two groups were similar.Conclusion: We introduced the BMI-7 protocol and demonstrated its standardized image quality and reduced radiation exposure in patients undergoing DCR.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Slot-Scan Digital Radiography of the Lower Extremities: a Comparison to Computed Radiography with Respect to Image Quality and Radiation Dose
    Lee, Kwang Hwi
    Kwon, Jong Won
    Yoon, Young Cheol
    Choi, Sang-Hee
    Jung, Jee Young
    Kim, Ji Hye
    Lee, Sang Jun
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (01) : 51 - 57
  • [12] MULTIPLE-BEAM EQUALIZATION RADIOGRAPHY IN CHEST RADIOLOGY - IMAGE QUALITY AND RADIATION-DOSE CONSIDERATIONS
    AXELSSON, B
    FORSBERG, H
    HANSSON, B
    HAVERLING, M
    ACTA RADIOLOGICA, 1991, 32 (01) : 12 - 17
  • [13] Radiation dose reduction and improvement of image quality in digital chest radiography by new spatial noise reduction algorithm
    Lee, Wonje
    Lee, Seungho
    Chong, Semin
    Lee, Kyungmin
    Lee, Jongha
    Choi, Jae Chol
    Lim, Changwon
    PLOS ONE, 2020, 15 (02):
  • [14] Dynamic chest image analysis:: Evaluation of model-based pulmonary perfusion analysis with pyramid images
    Liang, JM
    Järvi, T
    Kiuru, A
    Kormano, M
    Svedström, E
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 415 - 420
  • [15] Evaluation of pulmonary nodules and infection on chest CT with radiation dose equivalent to chest radiography: Prospective intra-individual comparison study to standard dose CT
    Martini, K.
    Barth, B. K.
    Nguyen-Kim, T. D. L.
    Baumueller, S.
    Alkadhi, H.
    Frauenfelder, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (02) : 360 - 365
  • [16] IMAGE QUALITY STUDY OF RADIATION-REDUCED COMBINED CHEST AND ABDOMEN/PELVIS CT COMPARED WITH A STANDARD PROTOCOL
    Bos, Denise
    Zensen, Sebastian
    Opitz, Marcel
    Haubold, Johannes
    Forsting, Michael
    Nassenstein, Kai
    Guberina, Nika
    Wetter, Axel
    RADIATION PROTECTION DOSIMETRY, 2021, 196 (3-4) : 190 - 198
  • [17] Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography
    Egbe N.O.
    Akintomide A.O.
    Inah G.B.
    Owolo E.
    Iranian Journal of Medical Physics, 2016, 13 (01) : 17 - 24
  • [18] Augmented Quadruple-Phase Contrast Media Administration and Triphasic Scan Protocol Increases Image Quality at Reduced Radiation Dose During Computed Tomography Urography
    Saade, Charbel
    Mohamad, May
    Kerek, Racha
    Hamieh, Nadine
    Deeb, Ibrahim Alsheikh
    El-Achkar, Bassam
    Tamim, Hani
    Razzak, Farah Abdul
    Haddad, Maurice
    Abi-Ghanem, Alain S.
    El-Merhi, Fadi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (02) : 216 - 221
  • [19] The effect of radiation dose reduction on clinical image quality in chest radiography of premature neonates using a dual-side readout technique computed radiography system
    Carlander, Anna
    Hansson, Jonny
    Soderberg, Jonas
    Steneryd, Karin
    Bath, Magnus
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 275 - 280
  • [20] Evaluating the effect of reduced entrance surface dose on neonatal chest imaging using subjective image quality evaluation
    Conradie, Anita
    Herbst, Charles Petrus
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (10): : 1368 - 1374