Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography

被引:0
|
作者
Egbe N.O. [1 ]
Akintomide A.O. [2 ]
Inah G.B. [2 ]
Owolo E. [1 ]
机构
[1] Department of Radiography & Radiological Science, University of Calabar
[2] Department of Radiology, University of Calabar, Calabar
关键词
Chest; Film; Image Quality; Pediatric; Radiation Dose; X-ray;
D O I
10.22038/IJMP.2016.7141
中图分类号
学科分类号
摘要
Introduction Over the years, the consequences of ionizing radiation have prompted major efforts towards producing radiographs of acceptable quality with dose values in compliance with safety standards and the ALARA principle. The aim of this study is to assess the compliance of radiation dose and image quality in a major Nigerian teaching hospital to the guidelines established by the Commission of European Communities (CEC) on optimized pediatric radiography. Materials and Methods The entrance skin dose (ESD) and image quality were studied among pediatric patients (age range: 0–15 years), referred to the hospital for chest radiographic examinations. Radiographic exposure factors were recorded in each examination. ESD was determined using a dose calculation software program (DoseCal®). The calculated ESD values were weighed against the CEC recommended doses and compared among different age groups through mean comparison. Based on the CEC image quality criteria, the resulting chest radiographs were assessed in terms of image quality. Results The overall image quality was high in over 70% of images (Fleiss’ kappa=0.63). The obtained ESD values were higher than the recommended CEC values (80 and 100 μGy for children aged 0-1 and 5 years, respectively). Also, the ESD values were higher than the recommended values by 26% in the age group of 0– 1 year and 9-10% in the other age groups. However, there was no significant difference between the age groups in terms of radiation dose. Conclusion The findings show that a considerable reduction in radiographic exposure factors (or doses) could still produce images with an acceptable diagnostic quality. This dose reduction could be achieved by reducing mAs, increasing kVp and adopting high-performance X-ray generators © 2016, Iranian Journal of Medical Physics.All Rights Reserved.
引用
收藏
页码:17 / 24
页数:7
相关论文
共 50 条
  • [1] Conceptus radiation dose and risk from chest screen-film radiography
    John Damilakis
    Kostas Perisinakis
    Panos Prassopoulos
    Evangelia Dimovasili
    Haralambos Varveris
    Nicholas Gourtsoyiannis
    European Radiology, 2003, 13 : 406 - 412
  • [2] Conceptus radiation dose and risk from chest screen-film radiography
    Damilakis, J
    Perisinakis, K
    Prassopoulos, P
    Dimovasili, E
    Varveris, H
    Gourtsoyiannis, N
    EUROPEAN RADIOLOGY, 2003, 13 (02) : 406 - 412
  • [3] SCREEN-FILM VERSUS FULL-FIELD DIGITAL MAMMOGRAPHY: RADIATION DOSE AND IMAGE QUALITY IN A LARGE TEACHING HOSPITAL
    Stantic, Tomislav J.
    Ciraj-Bjelac, Olivera E.
    Stojanovic, Saida S.
    Basta-Nikolic, Marijana D.
    Arandjic, Danijela D.
    Stoiljkovic, Dragana S.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2013, 28 (04): : 398 - 405
  • [4] DOSE EFFICIENCY OF SCREEN-FILM SYSTEMS USED IN PEDIATRIC RADIOGRAPHY
    COHEN, G
    WAGNER, LK
    MCDANIEL, DL
    ROBINSON, LH
    RADIOLOGY, 1984, 152 (01) : 187 - 193
  • [5] Screen-film and digital mammography - Image quality and radiation dose considerations
    Haus, AG
    Yaffe, MJ
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2000, 38 (04) : 871 - +
  • [6] Screen-film versus digital radiography of sacroiliac joints: evaluation of image quality and dose to patients
    Jablanovic, Dragoslav
    Ciraj-Bjelac, Olivera
    Damjanov, Nemanja
    Seric, Srdjan
    Radak-Perovic, Marija
    Arandjic, Danijela
    Maksimovic, Ruzica
    RADIATION PROTECTION DOSIMETRY, 2013, 155 (01) : 88 - 95
  • [7] Optimization of radiation dose and image quality in diagnostic radiology: Digital and screen-film imaging
    Gray, J
    Strauss, K
    MEDICAL PHYSICS, 2004, 31 (06) : 1805 - 1805
  • [8] IMAGE QUALITY AND PATIENT DOSE FOR DIFFERENT SCREEN-FILM COMBINATIONS
    GUIBELALDE, E
    FERNANDEZ, JM
    LLORCA, A
    RUIZ, MJ
    BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (794): : 166 - 173
  • [9] Demonstration of correlations between clinical and physical image quality measures in chest and lumbar spine screen-film radiography
    Sandborg, M
    Tingberg, A
    Dance, DR
    Lanhede, B
    Almén, A
    McVey, G
    Sund, P
    Kheddache, S
    Besjakov, J
    Mattsson, S
    Månsson, LG
    Carlsson, GA
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (882): : 520 - 528
  • [10] Amorphous silicon technology based digital radiography of the skeleton: Image quality and potential for dose reduction in comparison with screen-film radiography
    Volk, M
    Strotzer, M
    Holzknecht, N
    Manke, C
    Lenhart, M
    Gmeinwieser, JK
    RADIOLOGY, 1999, 213P : 328 - 328