Conceptus radiation dose and risk from chest screen-film radiography

被引:0
|
作者
John Damilakis
Kostas Perisinakis
Panos Prassopoulos
Evangelia Dimovasili
Haralambos Varveris
Nicholas Gourtsoyiannis
机构
[1] Department of Medical Physics,
[2] University of Crete,undefined
[3] Faculty of Medicine,undefined
[4] P.O. Box 1393,undefined
[5] 714 09 Iraklion,undefined
[6] Crete,undefined
[7] Greece,undefined
[8] Department of Radiology,undefined
[9] University of Crete,undefined
[10] Faculty of Medicine,undefined
[11] P.O. Box 1393,undefined
[12] 714 09 Iraklion,undefined
[13] Crete,undefined
[14] Greece,undefined
[15] Department of Radiotherapy,undefined
[16] University of Crete,undefined
[17] Faculty of Medicine,undefined
[18] P.O. Box 1393,undefined
[19] 714 09 Iraklion,undefined
[20] Crete,undefined
[21] Greece,undefined
来源
European Radiology | 2003年 / 13卷
关键词
Fetus Dose Chest Radiation Pregnancy;
D O I
暂无
中图分类号
学科分类号
摘要
The objectives of the present study were to (a) estimate the conceptus radiation dose and risks for pregnant women undergoing posteroanterior and anteroposterior (AP) chest radiographs, (b) study the conceptus dose as a function of chest thickness of the patient undergoing chest radiograph, and (c) investigate the possibility of a conceptus to receive a dose of more than 10 mGy, the level above which specific measurements of conceptus doses may be necessary. Thermoluminescent dosimeters were used for dose measurements in anthropomorphic phantoms simulating pregnancy at the three trimesters of gestation. The effect of chest thickness on conceptus dose and risk was studied by adding slabs of lucite on the anterior and posterior surface of the phantom chest. The conceptus risk for radiation-induced childhood fatal cancer and hereditary effects was calculated based on appropriate risk factors. The average AP chest dimension (da) was estimated for 51 women of childbearing age from chest CT examinations. The value of da was estimated to be 22.3 cm (17.4–27.2 cm). The calculated maximum conceptus dose was 107×10–3 mGy for AP chest radiographs performed during the third trimester of pregnancy with maternal chest thickness of 27.2 cm. This calculation was based on dose data obtained from measurements in the phantoms and da estimated from the patient group. The corresponding average excess of childhood cancer was 10.7 per million patients. The risk for hereditary effects was 1.1 per million births. Radiation dose for a conceptus increases exponentially as chest thickness increases. The conceptus dose at the third trimester is higher than that of the second and first trimesters. The results of the current study suggest that chest radiographs carried out in women at any time during gestation will result in a negligible increase in risk of radiation-induced harmful effects to the unborn child. After a properly performed maternal chest X-ray, there is no need for individual conceptus dose estimations.
引用
收藏
页码:406 / 412
页数:6
相关论文
共 50 条
  • [1] Conceptus radiation dose and risk from chest screen-film radiography
    Damilakis, J
    Perisinakis, K
    Prassopoulos, P
    Dimovasili, E
    Varveris, H
    Gourtsoyiannis, N
    EUROPEAN RADIOLOGY, 2003, 13 (02) : 406 - 412
  • [2] EVALUATION OF AN ASYMMETRIC SCREEN-FILM SYSTEM FOR CHEST RADIOGRAPHY
    MORISHITA, J
    MACMAHON, H
    DOI, K
    CARLIN, M
    SUKENOBU, Y
    MEDICAL PHYSICS, 1994, 21 (11) : 1769 - 1775
  • [3] EVALUATION OF ASYMMETRIC SCREEN-FILM SYSTEM FOR CHEST RADIOGRAPHY
    MORISHITA, J
    MACMAHON, H
    DOI, K
    RADIOLOGY, 1992, 185 : 250 - 250
  • [4] Comparison of an asymmetric screen-film combination with a conventional screen-film combination for chest radiography in 51 patients
    Greaney, T
    McCoy, C
    Masterson, J
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (837): : 929 - 932
  • [5] THRESHOLD PERCEPTION PERFORMANCE WITH COMPUTED AND SCREEN-FILM RADIOGRAPHY - IMPLICATIONS FOR CHEST RADIOGRAPHY
    DOBBINS, JT
    RICE, JJ
    BEAM, CA
    RAVIN, CE
    RADIOLOGY, 1992, 183 (01) : 179 - 187
  • [6] Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography
    Egbe N.O.
    Akintomide A.O.
    Inah G.B.
    Owolo E.
    Iranian Journal of Medical Physics, 2016, 13 (01) : 17 - 24
  • [7] Basic imaging properties of a new screen-film system for chest radiography
    Higashida, Y
    Murakami, Y
    Yoshida, A
    Kastuda, N
    Moribe, N
    Bussaka, H
    Hamada, T
    Yoshida, Y
    Hidetoshi, M
    Takahashi, M
    MEDICAL PHYSICS, 1996, 23 (08) : 1351 - 1357
  • [8] DOSE EFFICIENCY OF SCREEN-FILM SYSTEMS USED IN PEDIATRIC RADIOGRAPHY
    COHEN, G
    WAGNER, LK
    MCDANIEL, DL
    ROBINSON, LH
    RADIOLOGY, 1984, 152 (01) : 187 - 193
  • [9] Comparison of subjective and objective evaluation of screen-film systems for chest radiography
    Moeckli, R
    Verdun, FR
    Bochud, FO
    Valley, JF
    Hessler, C
    Schnyder, P
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 265 - 268
  • [10] Transition from screen-film to digital radiography:: Evolution of patient radiation doses at projection radiography
    Vano, Eliseo
    Fernandez, Jose Miguel
    Ten, Jose Ignacio
    Prieto, Carlos
    Gonzalez, Luciano
    Rodriguez, Ricardo
    de Las Heras, Hugo
    RADIOLOGY, 2007, 243 (02) : 461 - 466