Conceptus radiation dose and risk from chest screen-film radiography

被引:0
|
作者
John Damilakis
Kostas Perisinakis
Panos Prassopoulos
Evangelia Dimovasili
Haralambos Varveris
Nicholas Gourtsoyiannis
机构
[1] Department of Medical Physics,
[2] University of Crete,undefined
[3] Faculty of Medicine,undefined
[4] P.O. Box 1393,undefined
[5] 714 09 Iraklion,undefined
[6] Crete,undefined
[7] Greece,undefined
[8] Department of Radiology,undefined
[9] University of Crete,undefined
[10] Faculty of Medicine,undefined
[11] P.O. Box 1393,undefined
[12] 714 09 Iraklion,undefined
[13] Crete,undefined
[14] Greece,undefined
[15] Department of Radiotherapy,undefined
[16] University of Crete,undefined
[17] Faculty of Medicine,undefined
[18] P.O. Box 1393,undefined
[19] 714 09 Iraklion,undefined
[20] Crete,undefined
[21] Greece,undefined
来源
European Radiology | 2003年 / 13卷
关键词
Fetus Dose Chest Radiation Pregnancy;
D O I
暂无
中图分类号
学科分类号
摘要
The objectives of the present study were to (a) estimate the conceptus radiation dose and risks for pregnant women undergoing posteroanterior and anteroposterior (AP) chest radiographs, (b) study the conceptus dose as a function of chest thickness of the patient undergoing chest radiograph, and (c) investigate the possibility of a conceptus to receive a dose of more than 10 mGy, the level above which specific measurements of conceptus doses may be necessary. Thermoluminescent dosimeters were used for dose measurements in anthropomorphic phantoms simulating pregnancy at the three trimesters of gestation. The effect of chest thickness on conceptus dose and risk was studied by adding slabs of lucite on the anterior and posterior surface of the phantom chest. The conceptus risk for radiation-induced childhood fatal cancer and hereditary effects was calculated based on appropriate risk factors. The average AP chest dimension (da) was estimated for 51 women of childbearing age from chest CT examinations. The value of da was estimated to be 22.3 cm (17.4–27.2 cm). The calculated maximum conceptus dose was 107×10–3 mGy for AP chest radiographs performed during the third trimester of pregnancy with maternal chest thickness of 27.2 cm. This calculation was based on dose data obtained from measurements in the phantoms and da estimated from the patient group. The corresponding average excess of childhood cancer was 10.7 per million patients. The risk for hereditary effects was 1.1 per million births. Radiation dose for a conceptus increases exponentially as chest thickness increases. The conceptus dose at the third trimester is higher than that of the second and first trimesters. The results of the current study suggest that chest radiographs carried out in women at any time during gestation will result in a negligible increase in risk of radiation-induced harmful effects to the unborn child. After a properly performed maternal chest X-ray, there is no need for individual conceptus dose estimations.
引用
收藏
页码:406 / 412
页数:6
相关论文
共 50 条
  • [31] COMPARISON OF AN ULTRAVIOLET SCREEN-FILM SYSTEM WITH A RARE-EARTH SCREEN-FILM SYSTEM FOR USE IN PEDIATRIC RADIOGRAPHY
    CRUZ, BK
    YOUNGBLOOD, DD
    SWENSON, KN
    SHELTON, DK
    RADIOLOGY, 1992, 185 : 232 - 232
  • [32] Chest radiography: Depiction of normal anatomy and pathologic structures with selenium-based digital radiography versus conventional screen-film radiography
    Woodard, PK
    Slone, RM
    Gierada, DS
    Reiker, GG
    Pilgram, TK
    Jost, RG
    RADIOLOGY, 1997, 203 (01) : 197 - 201
  • [33] LARGE-SCREEN IMAGE INTENSIFIER PHOTOFLUOROGRAPHY COMPARED WITH FULL-SIZE SCREEN-FILM TECHNIQUE IN CHEST RADIOGRAPHY
    MANNINEN, H
    RYTKONEN, H
    SOIMAKALLIO, S
    TERHO, EO
    HENTUNEN, J
    ACTA RADIOLOGICA-DIAGNOSIS, 1985, 26 (05): : 525 - 533
  • [34] SCREEN-FILM MAMMOGRAPHY UPDATE - X-RAY UNITS, BREAST COMPRESSION, GRIDS, SCREEN-FILM CHARACTERISTICS, AND RADIATION-DOSE
    HAUS, AG
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 486 : 152 - 159
  • [35] Technical aspects of screen-film radiography, film processing, and quality control
    Gray, JE
    RADIOGRAPHICS, 1997, 17 (01) : 177 - 187
  • [36] Mixture distribution and receiver operating characteristic analysis of bedside chest imaging with screen-film and computed radiography
    Kundel, HL
    Polansky, M
    ACADEMIC RADIOLOGY, 1997, 4 (01) : 1 - 7
  • [37] COMPARISON OF STEREOSCOPICALLY ACQUIRED CHEST IMAGES BY USING STORAGE PHOSPHOR RADIOGRAPHY AND AN ASYMMETRIC SCREEN-FILM SYSTEM
    HARTMAN, TE
    AUGHENBAUGH, GL
    BROWN, LR
    HARMS, GF
    KARSELL, PR
    MILLER, WE
    RADIOLOGY, 1995, 197 : 341 - 341
  • [38] Analysis on testing of noise in radiography resulted from different screen-film systems
    Feng, SL
    Zhang, ZG
    Bai, J
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 730 - 732
  • [39] PORTABLE CHEST IMAGING - COMPARISON OF STORAGE PHOSPHOR DIGITAL, ASYMMETRIC SCREEN-FILM, AND CONVENTIONAL SCREEN-FILM SYSTEMS
    NIKLASON, LT
    CHAN, HP
    CASCADE, PN
    CHANG, CL
    CHEE, PW
    MATHEWS, JF
    RADIOLOGY, 1993, 186 (02) : 387 - 393
  • [40] COMPARISON OF STEREOSCOPICALLY ACQUIRED CHEST IMAGES WITH USE OF STORAGE PHOSPHOR RADIOGRAPHY AND AN ASYMMETRIC SCREEN-FILM SYSTEM
    HARTMAN, TE
    AUGHENBAUGH, GL
    BROWN, LR
    HARMS, GF
    KARSELL, PR
    MILLER, WE
    RADIOLOGY, 1995, 197 : 525 - 525