Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography

被引:0
|
作者
Egbe N.O. [1 ]
Akintomide A.O. [2 ]
Inah G.B. [2 ]
Owolo E. [1 ]
机构
[1] Department of Radiography & Radiological Science, University of Calabar
[2] Department of Radiology, University of Calabar, Calabar
关键词
Chest; Film; Image Quality; Pediatric; Radiation Dose; X-ray;
D O I
10.22038/IJMP.2016.7141
中图分类号
学科分类号
摘要
Introduction Over the years, the consequences of ionizing radiation have prompted major efforts towards producing radiographs of acceptable quality with dose values in compliance with safety standards and the ALARA principle. The aim of this study is to assess the compliance of radiation dose and image quality in a major Nigerian teaching hospital to the guidelines established by the Commission of European Communities (CEC) on optimized pediatric radiography. Materials and Methods The entrance skin dose (ESD) and image quality were studied among pediatric patients (age range: 0–15 years), referred to the hospital for chest radiographic examinations. Radiographic exposure factors were recorded in each examination. ESD was determined using a dose calculation software program (DoseCal®). The calculated ESD values were weighed against the CEC recommended doses and compared among different age groups through mean comparison. Based on the CEC image quality criteria, the resulting chest radiographs were assessed in terms of image quality. Results The overall image quality was high in over 70% of images (Fleiss’ kappa=0.63). The obtained ESD values were higher than the recommended CEC values (80 and 100 μGy for children aged 0-1 and 5 years, respectively). Also, the ESD values were higher than the recommended values by 26% in the age group of 0– 1 year and 9-10% in the other age groups. However, there was no significant difference between the age groups in terms of radiation dose. Conclusion The findings show that a considerable reduction in radiographic exposure factors (or doses) could still produce images with an acceptable diagnostic quality. This dose reduction could be achieved by reducing mAs, increasing kVp and adopting high-performance X-ray generators © 2016, Iranian Journal of Medical Physics.All Rights Reserved.
引用
收藏
页码:17 / 24
页数:7
相关论文
共 50 条
  • [31] COMPARISON OF THE IMAGE QUALITY OF A HIGH-RESOLUTION SCREEN-FILM SYSTEM AND A DIGITAL FLAT PANEL DETECTOR SYSTEM IN AVIAN RADIOGRAPHY
    Bochmann, Monika
    Ludewig, Eberhard
    Krautwald-Junghanns, Maria-Elisabeth
    Pees, Michael
    VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (03) : 256 - 261
  • [32] BIMETAL ANODE WITH TUNGSTEN OR RHODIUM - COMPARATIVE-STUDIES ON IMAGE QUALITY AND RADIATION EXPOSURE IN SCREEN-FILM MAMMOGRAPHY
    FUNKE, M
    HERMANN, KP
    BREITER, N
    MORITZ, J
    MULLER, D
    GRABBE, E
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 163 (05): : 388 - 394
  • [33] A COMPARISON OF IMAGE QUALITY AND DOSE REQUIREMENTS OF A NEW CONVENTIONAL FILM-SCREEN SYSTEM FOR SKELETAL RADIOGRAPHY
    FREITAG, P
    GUCKEL, C
    FOURNIER, PJ
    ROTH, J
    STEINBRICH, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 163 (04): : 297 - 302
  • [34] Detection of simulated chest lesions with normal and reduced radiation dose -: Comparison of conventional screen-film radiography and a flat-panel x-ray detector based on amorphous silicon
    Strotzer, M
    Gmeinwieser, JK
    Völk, M
    Fründ, R
    Seitz, J
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 1998, 33 (02) : 98 - 103
  • [35] Digital slot-scan charge-coupled device radiography versus AMBER and Bucky screen-film radiography: Comparison of image quality in a phantom study
    Veldkamp, WJH
    Kroft, LJM
    Mertens, BJA
    Geleijns, J
    RADIOLOGY, 2005, 235 (03) : 857 - 866
  • [36] MULTIPLE-BEAM EQUALIZATION RADIOGRAPHY IN CHEST RADIOLOGY - IMAGE QUALITY AND RADIATION-DOSE CONSIDERATIONS
    AXELSSON, B
    FORSBERG, H
    HANSSON, B
    HAVERLING, M
    ACTA RADIOLOGICA, 1991, 32 (01) : 12 - 17
  • [37] OPTIMIZING IMAGE QUALITY, RADIATION DOSAGE TO THE PATIENT AND TO THE DETECTOR IN PEDIATRIC CHEST RADIOGRAPHY: A PHANTOM STUDY OF A PORTABLE DIGITAL RADIOGRAPHY SYSTEM
    Shahgeldi, Kaveh
    Sjoberg, Tommy
    Nordstrom, Jonny
    Lesanu, Radu
    Svahn, Tony Martin
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (04) : 414 - 420
  • [38] Optimization of image quality and dose in adult and pediatric chest radiography via Monte Carlo simulation and experimental methods
    Mendes, Hitalo R.
    Silva, Julio C.
    Marcondes, Mariana
    Tomal, Alessandra
    RADIATION PHYSICS AND CHEMISTRY, 2022, 201
  • [39] Chest radiographic image quality: Comparison of asymmetric screen-film, digital storage phosphor, and digital selenium drum systems - Preliminary study
    Beute, GH
    Flynn, MJ
    Eyler, WR
    Samei, E
    Spizarny, DL
    Zylak, CJ
    RADIOGRAPHICS, 1998, 18 (03) : 745 - 754
  • [40] Radiation dose reduction and improvement of image quality in digital chest radiography by new spatial noise reduction algorithm
    Lee, Wonje
    Lee, Seungho
    Chong, Semin
    Lee, Kyungmin
    Lee, Jongha
    Choi, Jae Chol
    Lim, Changwon
    PLOS ONE, 2020, 15 (02):