Validation of an AI-based algorithm for measurement of the thoracic aortic diameter in low-dose chest CT

被引:3
|
作者
Hamelink, I. Iris [1 ]
de Heide, E. Erik Jan [1 ]
Pelgrim, G. J. Gert Jan [1 ]
Kwee, T. C. Thomas [1 ]
van Ooijen, P. M. A. Peter [2 ,3 ]
de Bock, G. H. Truuske [4 ]
Vliegenthart, R. Rozemarijn [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, NL- 9713 GZ Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Radiat Oncol, NL-9713 GZ Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Data Sci Hlth DASH, NL-9713 GZ Groningen, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Epidemiol, NL-9713 GZ Groningen, Netherlands
关键词
Thoracic aortic aneurysm; Chest CT; Artificial intelligence; ANGIOGRAPHY;
D O I
10.1016/j.ejrad.2023.111067
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To evaluate the performance of artificial intelligence (AI) software for automatic thoracic aortic diameter assessment in a heterogeneous cohort with low-dose, non-contrast chest computed tomography (CT). Materials and methods: Participants of the Imaging in Lifelines (ImaLife) study who underwent low-dose, non-contrast chest CT (August 2017-May 2022) were included using random samples of 80 participants <50y, >= 80y, and with thoracic aortic diameter >= 40 mm. AI-based aortic diameters at eight guideline compliant positions were compared with manual measurements. In 90 examinations (30 per group) diameters were reassessed for intra- and inter-reader variability, which was compared to discrepancy of the AI system using Bland-Altman analysis, paired samples t-testing and linear mixed models. Results: We analyzed 240 participants (63 +/- 16 years; 50 % men). AI evaluation failed in 11 cases due to incorrect segmentation (4.6 %), leaving 229 cases for analysis. No difference was found in aortic diameter between manual and automatic measurements (32.7 +/- 6.4 mm vs 32.7 +/- 6.0 mm, p = 0.70). Bland-Altman analysis yielded no systematic bias and a repeatability coefficient of 4.0 mm for AI. Mean discrepancy of AI (1.3 +/- 1.6 mm) was comparable to inter-reader variability (1.4 +/- 1.4 mm); only at the proximal aortic arch showed AI higher discrepancy (2.0 +/- 1.8 mm vs 0.9 +/- 0.9 mm, p < 0.001). No difference between AI discrepancy and inter-reader variability was found for any subgroup (all: p > 0.05). Conclusion: The AI software can accurately measure thoracic aortic diameters, with discrepancy to a human reader similar to inter-reader variability in a range from normal to dilated aortas.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Segmentation of Individual Ribs from Low-dose Chest CT
    Lee, Jaesung
    Reeves, Anthony P.
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
  • [42] A prospective evaluation of low-dose spiral chest CT in children
    Rigsby, CK
    Benya, EC
    Saker, MC
    Lin, PP
    Shore, RM
    RADIOLOGY, 2001, 221 : 574 - 574
  • [43] Real world validation of an AI-based CT hemorrhage detection tool
    Wang, Dongang
    Jin, Ruilin
    Shieh, Chun-Chien
    Ng, Adrian Y.
    Pham, Hiep
    Dugal, Tej
    Barnett, Michael
    Winoto, Luis
    Wang, Chenyu
    Barnett, Yael
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [44] Automated aortic calcium scoring on low-dose chest computed tomography
    Isgum, Ivana
    Rutten, Annemarieke
    Prokop, Mathias
    Staring, Marius
    Klein, Stefan
    Pluim, Josien P. W.
    Viergever, Max A.
    van Ginneken, Bram
    MEDICAL PHYSICS, 2010, 37 (02) : 714 - 723
  • [45] An AI-based algorithm for the automatic evaluation of image quality in canine thoracic radiographs
    Banzato, Tommaso
    Wodzinski, Marek
    Burti, Silvia
    Vettore, Eleonora
    Muller, Henning
    Zotti, Alessandro
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [46] An AI-based algorithm for the automatic evaluation of image quality in canine thoracic radiographs
    Tommaso Banzato
    Marek Wodzinski
    Silvia Burti
    Eleonora Vettore
    Henning Muller
    Alessandro Zotti
    Scientific Reports, 13
  • [47] Thoracic aortic size in Brazilian smokers: measures using low-dose chest computed tomography anatomical and epidemiological assessment
    Lembranca, Lucas
    Teivelis, Marcelo Passos
    Tachibana, Adriano
    dos Santos, Ricardo Sales
    Joo, Richard Wonuh
    Zippo, Emanuela
    Wolosker, Nelson
    CLINICS, 2021, 76 : 1 - 6
  • [48] FEASIBILITY OF HIGH-RESOLUTION, LOW-DOSE CHEST CT IN EVALUATING THE PEDIATRIC CHEST
    AMBROSINO, MM
    GENIESER, NB
    ROCHE, KJ
    KAUL, A
    LAWRENCE, RM
    PEDIATRIC RADIOLOGY, 1994, 24 (01) : 6 - 10
  • [49] Diagnostic value of using epicardial fat measurement on screening low-dose chest CT for the prediction of metabolic syndrome A cross-validation study
    Kim, Hyun Ji
    Lee, Heon
    Lee, Bora
    Lee, Jae Wook
    Shin, Kyung Eun
    Suh, Jon
    Park, Hyun Woo
    Kim, Jeong A.
    MEDICINE, 2019, 98 (07)
  • [50] Low-Dose CT Denoising Algorithm Based on Image Cartoon Texture Decomposition
    Hao Chen
    Yi Liu
    Pengcheng Zhang
    Jiaqi Kang
    Zhiyuan Li
    Weiting Cheng
    Zhiguo Gui
    Circuits, Systems, and Signal Processing, 2024, 43 : 3073 - 3101