Accuracy and Potential Interferences of Continuous Glucose Monitoring Sensors in the Hospital

被引:14
|
作者
Bellido, Virginia [1 ,2 ]
Freckman, Guido [3 ]
Perez, Antonio [4 ]
Galindo, Rodolfo J. [5 ,6 ]
机构
[1] Hosp Univ Virgen del Rocio, Unidad Gest Clin Endocrinol & Nutr, Seville, Spain
[2] Univ Seville, Hosp Univ Virgen del Rocio, Inst Biomed Sevilla IBiS, CSIC, Seville, Spain
[3] Univ Ulm, Inst Diabet Technol, Forsch & Entwicklungsgesell mbH, Ulm, Germany
[4] Univ Autonoma Barcelona, Hosp St Creu i St Pau, Serv Endocrinol & Nutr, IIB St Pau,CIBER Diabet & Enfermedades Metab Asoc, Barcelona, Spain
[5] Univ Miami, Miller Sch Med, Div Endocrinol Diabet & Metab, Miami, FL USA
[6] Univ Miami, Miller Sch Med, Div Endocrinol Diabet & Metab, Med, 1450 NW 10th Ave, Suite 202, Miami, FL 33136 USA
关键词
Accuracy; CGM; glucose monitoring; inpatient diabetes; INTENSIVE-CARE-UNIT; CRITICALLY-ILL PATIENTS; OPERATING-ROOM; SYSTEM; PERFORMANCE; CGM; SAFETY; IMPLEMENTATION; FEASIBILITY; EVERSENSE;
D O I
10.1016/j.eprac.2023.06.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For years, the standard of care for monitoring dysglycemia in hospitalized patients was capillary blood glucose (CBG) testing with point-of-care glucose meters. Recently, there has been a revolution in novel factory-calibrated continuous glucose monitoring (CGM) systems. Newer CGMs are smaller and less expensive, have improved accuracy and longer wear time, and do not require fingerstick CBG for calibration, resulting in increased utilization in ambulatory settings. Consequently, hospitals have noticed increased usability of CGMs among hospitalized patients and expect a progressive continued increase. During the COVID-19 pandemic, there was a critical need for innovative approaches to glycemic monitoring, with several pilot implementation projects using CGM in the intensive care unit and non-intensive care unit settings, further boosting the evidence in this area. Hence, recent guidelines have provided recommendations for the use of CGM in specific hospital scenarios and highlighted the potential of CGM to overcome CBG limitations for glucose monitoring in the inpatient setting. In this review, we provide the following: 1) an up-to-date review of the accuracy of the newer CGMs in hospitalized patients, 2) a discussion of standards for CGM accuracy metrics, 3) a contemporary overview of potential interferences that may cause inaccuracies or poor CGM performance, and 4) required steps for full regulatory approval of CGMs in the hospital and future research steps to advance the field forward. (c) 2023 AACE. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:919 / 927
页数:9
相关论文
共 50 条
  • [31] Multivariate calibration of NIR spectroscopic sensors for continuous glucose monitoring
    Goodarzi, Mohammad
    Sharma, Sandeep
    Ramon, Herman
    Saeys, Wouter
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 67 : 147 - 158
  • [32] DYNAMIC INTERFERENCE TEST METHOD FOR CONTINUOUS GLUCOSE MONITORING SENSORS
    Pfuetzner, A.
    Jensch, H.
    Srikanthamoorthy, G.
    Thome, N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A162 - A163
  • [33] COMPARISON OF DIFFERENT CALIBRATION STRATEGIES FOR CONTINUOUS GLUCOSE MONITORING SENSORS
    Vettoretti, M.
    Facchinetti, A.
    Sparacino, G.
    Del Favero, S.
    Cobelli, C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A16 - A16
  • [34] Clinical assessment and mathematical modeling of the accuracy of continuous glucose sensors (CGS)
    Kovatchev, Boris P.
    King, Christopher
    Breton, Marc
    Anderson, Stacey
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 218 - 221
  • [35] Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis
    Clarke, WL
    Anderson, S
    Farhy, L
    Breton, M
    Gonder-Frederick, L
    Cox, D
    Kovatchev, B
    DIABETES CARE, 2005, 28 (10) : 2412 - 2417
  • [36] Accuracy and feasibility of continuous glucose monitoring system in pancreatectomy patients
    Choi, Yoo Jin
    Jeon, Su Min
    Yu, Sehyeon
    Jo, Hye-Sung
    Kim, Dong-Sik
    Yu, Young-Dong
    LANGENBECKS ARCHIVES OF SURGERY, 2025, 410 (01)
  • [37] The Accuracy of Continuous Glucose Monitoring in the Medical Intensive Care Unit
    Tingsarat, Wannita
    Buranasupkajorn, Patinut
    Khovidhunkit, Weerapan
    Boonchaya-anant, Patchaya
    Laichuthai, Nitchakarn
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (06): : 1550 - 1554
  • [38] Accuracy and reliability of continuous glucose monitoring in critically ill patients
    Holzinger, Ulrike
    Warszawska, Joanna
    Kitzberger, Reinhaid
    Fuhrmann, Valentin
    Schenk, Peter
    Herkner, Harald
    Madl, Christian
    CRITICAL CARE MEDICINE, 2007, 35 (12) : A137 - A137
  • [39] Real-Time Improvement of Continuous Glucose Monitoring Accuracy
    Facchinetti, Andrea
    Sparacino, Giovanni
    Guerra, Stefania
    Luijf, Yoeri M.
    DeVries, J. Hans
    Mader, Julia K.
    Ellmerer, Martin
    Benesch, Carsten
    Heinemann, Lutz
    Bruttomesso, Daniela
    Avogaro, Angelo
    Cobelli, Claudio
    DIABETES CARE, 2013, 36 (04) : 793 - 800
  • [40] Accuracy of MiniMed continuous glucose monitoring system during hypoglycaemia
    Kerr, D
    Cheyne, EH
    Weiss, M
    Ryder, J
    Cavan, DA
    DIABETOLOGIA, 2001, 44 : A239 - A239