Accuracy and Potential Interferences of Continuous Glucose Monitoring Sensors in the Hospital

被引:14
|
作者
Bellido, Virginia [1 ,2 ]
Freckman, Guido [3 ]
Perez, Antonio [4 ]
Galindo, Rodolfo J. [5 ,6 ]
机构
[1] Hosp Univ Virgen del Rocio, Unidad Gest Clin Endocrinol & Nutr, Seville, Spain
[2] Univ Seville, Hosp Univ Virgen del Rocio, Inst Biomed Sevilla IBiS, CSIC, Seville, Spain
[3] Univ Ulm, Inst Diabet Technol, Forsch & Entwicklungsgesell mbH, Ulm, Germany
[4] Univ Autonoma Barcelona, Hosp St Creu i St Pau, Serv Endocrinol & Nutr, IIB St Pau,CIBER Diabet & Enfermedades Metab Asoc, Barcelona, Spain
[5] Univ Miami, Miller Sch Med, Div Endocrinol Diabet & Metab, Miami, FL USA
[6] Univ Miami, Miller Sch Med, Div Endocrinol Diabet & Metab, Med, 1450 NW 10th Ave, Suite 202, Miami, FL 33136 USA
关键词
Accuracy; CGM; glucose monitoring; inpatient diabetes; INTENSIVE-CARE-UNIT; CRITICALLY-ILL PATIENTS; OPERATING-ROOM; SYSTEM; PERFORMANCE; CGM; SAFETY; IMPLEMENTATION; FEASIBILITY; EVERSENSE;
D O I
10.1016/j.eprac.2023.06.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For years, the standard of care for monitoring dysglycemia in hospitalized patients was capillary blood glucose (CBG) testing with point-of-care glucose meters. Recently, there has been a revolution in novel factory-calibrated continuous glucose monitoring (CGM) systems. Newer CGMs are smaller and less expensive, have improved accuracy and longer wear time, and do not require fingerstick CBG for calibration, resulting in increased utilization in ambulatory settings. Consequently, hospitals have noticed increased usability of CGMs among hospitalized patients and expect a progressive continued increase. During the COVID-19 pandemic, there was a critical need for innovative approaches to glycemic monitoring, with several pilot implementation projects using CGM in the intensive care unit and non-intensive care unit settings, further boosting the evidence in this area. Hence, recent guidelines have provided recommendations for the use of CGM in specific hospital scenarios and highlighted the potential of CGM to overcome CBG limitations for glucose monitoring in the inpatient setting. In this review, we provide the following: 1) an up-to-date review of the accuracy of the newer CGMs in hospitalized patients, 2) a discussion of standards for CGM accuracy metrics, 3) a contemporary overview of potential interferences that may cause inaccuracies or poor CGM performance, and 4) required steps for full regulatory approval of CGMs in the hospital and future research steps to advance the field forward. (c) 2023 AACE. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:919 / 927
页数:9
相关论文
共 50 条
  • [21] In vivo sensors for continuous monitoring of blood gases, glucose, and lactate: Biocompatibility challenges and potential solutions
    Frost, Megan C.
    Wolf, Alexander K.
    Meyerhoff, Mark E.
    RSC Detection Science, 2013, : 129 - 155
  • [22] Accuracy and reliability of continuous glucose monitoring at the ICU; a head to head comparison of two subcutaneous glucose sensors in cardiac surgery patients
    Siegelaar, S. E.
    Barwari, T.
    Hermanides, J.
    Stooker, W.
    van der Voort, P. H. J.
    DeVries, J. H.
    DIABETOLOGIA, 2010, 53 : S102 - S102
  • [23] Accuracy of real-time glucose values using continuous glucose monitoring:: the Guardian™ II continuous glucose monitoring system
    Schwartz, SL
    Buchea, O
    Shin, J
    Hoss, U
    Shah, R
    DIABETOLOGIA, 2004, 47 : A315 - A315
  • [24] Evaluating the Accuracy of Continuous Glucose Monitoring by the Patient through Continuous Glucose Error Grid Analysis
    Honsova, Sarka
    Navratil, Tomas
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 59 - 63
  • [25] Importance of FDA-Integrated Continuous Glucose Monitors to Ensure Accuracy of Continuous Glucose Monitoring
    Klonoff, David C.
    Gabbay, Monica
    Moon, Sun Joon
    Wilmot, Emma G.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024,
  • [26] Remote Continuous Glucose Monitoring following Hospital Discharge
    Folk, Sara
    Sobol, Trevor
    Gatti, Thaina
    Harris, Cara
    Faulds, Eileen R.
    Buschur, Elizabeth
    Wyne, Kathleen
    Duncan, Philicia
    Dungan, Kathleen M.
    DIABETES, 2024, 73
  • [27] Use of Continuous Glucose Monitoring to Prevent Hypoglycemia in the Hospital
    Faulds, Eileen
    Mapes, Sheila
    Karnes, Lindsey
    Dungan, Kathleen M.
    Wyne, Kathleen
    DIABETES, 2016, 65 : A544 - A545
  • [28] How accurate is continuous blood glucose monitoring in the hospital?
    Jecht, Michael
    DIABETOLOGIE, 2024, 20 (08): : 899 - 901
  • [29] Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
    Zafar, Hima
    Channa, Asma
    Jeoti, Varun
    Stojanovic, Goran M.
    SENSORS, 2022, 22 (02)
  • [30] Wearable Continuous Glucose Monitoring Sensors: A Revolution in Diabetes Treatment
    Cappon, Giacomo
    Acciaroli, Giada
    Vettoretti, Martina
    Facchinetti, Andrea
    Sparacino, Giovanni
    ELECTRONICS, 2017, 6 (03):