Accuracy and Potential Interferences of Continuous Glucose Monitoring Sensors in the Hospital

被引:14
|
作者
Bellido, Virginia [1 ,2 ]
Freckman, Guido [3 ]
Perez, Antonio [4 ]
Galindo, Rodolfo J. [5 ,6 ]
机构
[1] Hosp Univ Virgen del Rocio, Unidad Gest Clin Endocrinol & Nutr, Seville, Spain
[2] Univ Seville, Hosp Univ Virgen del Rocio, Inst Biomed Sevilla IBiS, CSIC, Seville, Spain
[3] Univ Ulm, Inst Diabet Technol, Forsch & Entwicklungsgesell mbH, Ulm, Germany
[4] Univ Autonoma Barcelona, Hosp St Creu i St Pau, Serv Endocrinol & Nutr, IIB St Pau,CIBER Diabet & Enfermedades Metab Asoc, Barcelona, Spain
[5] Univ Miami, Miller Sch Med, Div Endocrinol Diabet & Metab, Miami, FL USA
[6] Univ Miami, Miller Sch Med, Div Endocrinol Diabet & Metab, Med, 1450 NW 10th Ave, Suite 202, Miami, FL 33136 USA
关键词
Accuracy; CGM; glucose monitoring; inpatient diabetes; INTENSIVE-CARE-UNIT; CRITICALLY-ILL PATIENTS; OPERATING-ROOM; SYSTEM; PERFORMANCE; CGM; SAFETY; IMPLEMENTATION; FEASIBILITY; EVERSENSE;
D O I
10.1016/j.eprac.2023.06.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For years, the standard of care for monitoring dysglycemia in hospitalized patients was capillary blood glucose (CBG) testing with point-of-care glucose meters. Recently, there has been a revolution in novel factory-calibrated continuous glucose monitoring (CGM) systems. Newer CGMs are smaller and less expensive, have improved accuracy and longer wear time, and do not require fingerstick CBG for calibration, resulting in increased utilization in ambulatory settings. Consequently, hospitals have noticed increased usability of CGMs among hospitalized patients and expect a progressive continued increase. During the COVID-19 pandemic, there was a critical need for innovative approaches to glycemic monitoring, with several pilot implementation projects using CGM in the intensive care unit and non-intensive care unit settings, further boosting the evidence in this area. Hence, recent guidelines have provided recommendations for the use of CGM in specific hospital scenarios and highlighted the potential of CGM to overcome CBG limitations for glucose monitoring in the inpatient setting. In this review, we provide the following: 1) an up-to-date review of the accuracy of the newer CGMs in hospitalized patients, 2) a discussion of standards for CGM accuracy metrics, 3) a contemporary overview of potential interferences that may cause inaccuracies or poor CGM performance, and 4) required steps for full regulatory approval of CGMs in the hospital and future research steps to advance the field forward. (c) 2023 AACE. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:919 / 927
页数:9
相关论文
共 50 条
  • [11] Safety and accuracy of neonatal continuous glucose monitoring
    Ohishi, Akira
    Ueno, Daizo
    Fujita, Tomoka
    Segawa, Yuki
    Yamamoto, Takuya
    Fujisawa, Yasuko
    Iijima, Shigeo
    PEDIATRICS INTERNATIONAL, 2023, 65 (01)
  • [12] Glucose homeostasis in cirrhosis: accuracy of hemoglobin a1c and potential usefulness of continuous glucose monitoring
    Addepally, N. S.
    Garcia-Saenz-de-Sicilia, Mauricio
    Goulden, Peter A.
    Duarte-Rojo, Andres
    HEPATOLOGY, 2016, 64 : 706A - 707A
  • [13] The Impact of Prolonged Use of Continuous Glucose Monitoring Sensors in Patients with Diabetes Mellitus: Accuracy and Financial Burden
    Erfanyukova, Anna
    Donin, Gleb
    Holubova, Anna
    Muzik, Jan
    2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
  • [14] Patent analysis of digital sensors for continuous glucose monitoring
    Litvinova, Olena
    Eitenberger, Magdalena
    Bilir, Aylin
    Yeung, Andy Wai Kan
    Parvanov, Emil D. D.
    MohanaSundaram, ArunSundar
    Horbanczuk, Jaroslaw Olav
    Atanasov, Atanas G. G.
    Willschke, Harald
    FRONTIERS IN PUBLIC HEALTH, 2023, 11
  • [15] Performance of subcutaneously implanted glucose sensors for continuous monitoring
    Gerritsen, M
    Jansen, JA
    Lutterman, JA
    NETHERLANDS JOURNAL OF MEDICINE, 1999, 54 (04): : 167 - 179
  • [16] Recent advances in optical sensors for continuous glucose monitoring
    Ahmed, Israr
    Jiang, Nan
    Shao, Xinge
    Elsherif, Mohamed
    Alam, Fahad
    Salih, Ahmed
    Butt, Haider
    Yetisen, Ali K.
    SENSORS & DIAGNOSTICS, 2022, 1 (06): : 1098 - 1125
  • [17] Consistency of Continuous Ambulatory Interstitial Glucose Monitoring Sensors
    Wu, Pei T.
    Segovia, David E.
    Lee, Cathy C.
    Nguyen, Kim-Lien
    BIOSENSORS-BASEL, 2018, 8 (02):
  • [18] Accuracy of flash glucose monitoring and continuous glucose monitoring technologies: Implications for clinical practice
    Ajjan, Ramzi A.
    Cummings, Michael H.
    Jennings, Peter
    Leelarathna, Lalantha
    Rayman, Gerry
    Wilmot, Emma G.
    DIABETES & VASCULAR DISEASE RESEARCH, 2018, 15 (03): : 175 - 184
  • [19] Accuracy of Continuous Glucose Monitoring in Hemodialysis Patients With Diabetes
    Narasaki, Yoko
    Kalantar-Zadeh, Kamyar
    Daza, Andrea C.
    You, Amy S.
    Novoa, Alejandra
    Peralta, Renal Amel
    Siu, Man Kit Michael
    Nguyen, Danh V.
    Rhee, Connie M.
    DIABETES CARE, 2024, 47 (11)
  • [20] Assessing Glucose Trend Accuracy with a Novel Continuous Glucose Monitoring System
    Johnson, Terri
    Zhang, Xiaohe
    Balo, Andrew
    DIABETES, 2018, 67