Accuracy and Potential Interferences of Continuous Glucose Monitoring Sensors in the Hospital

被引:14
|
作者
Bellido, Virginia [1 ,2 ]
Freckman, Guido [3 ]
Perez, Antonio [4 ]
Galindo, Rodolfo J. [5 ,6 ]
机构
[1] Hosp Univ Virgen del Rocio, Unidad Gest Clin Endocrinol & Nutr, Seville, Spain
[2] Univ Seville, Hosp Univ Virgen del Rocio, Inst Biomed Sevilla IBiS, CSIC, Seville, Spain
[3] Univ Ulm, Inst Diabet Technol, Forsch & Entwicklungsgesell mbH, Ulm, Germany
[4] Univ Autonoma Barcelona, Hosp St Creu i St Pau, Serv Endocrinol & Nutr, IIB St Pau,CIBER Diabet & Enfermedades Metab Asoc, Barcelona, Spain
[5] Univ Miami, Miller Sch Med, Div Endocrinol Diabet & Metab, Miami, FL USA
[6] Univ Miami, Miller Sch Med, Div Endocrinol Diabet & Metab, Med, 1450 NW 10th Ave, Suite 202, Miami, FL 33136 USA
关键词
Accuracy; CGM; glucose monitoring; inpatient diabetes; INTENSIVE-CARE-UNIT; CRITICALLY-ILL PATIENTS; OPERATING-ROOM; SYSTEM; PERFORMANCE; CGM; SAFETY; IMPLEMENTATION; FEASIBILITY; EVERSENSE;
D O I
10.1016/j.eprac.2023.06.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For years, the standard of care for monitoring dysglycemia in hospitalized patients was capillary blood glucose (CBG) testing with point-of-care glucose meters. Recently, there has been a revolution in novel factory-calibrated continuous glucose monitoring (CGM) systems. Newer CGMs are smaller and less expensive, have improved accuracy and longer wear time, and do not require fingerstick CBG for calibration, resulting in increased utilization in ambulatory settings. Consequently, hospitals have noticed increased usability of CGMs among hospitalized patients and expect a progressive continued increase. During the COVID-19 pandemic, there was a critical need for innovative approaches to glycemic monitoring, with several pilot implementation projects using CGM in the intensive care unit and non-intensive care unit settings, further boosting the evidence in this area. Hence, recent guidelines have provided recommendations for the use of CGM in specific hospital scenarios and highlighted the potential of CGM to overcome CBG limitations for glucose monitoring in the inpatient setting. In this review, we provide the following: 1) an up-to-date review of the accuracy of the newer CGMs in hospitalized patients, 2) a discussion of standards for CGM accuracy metrics, 3) a contemporary overview of potential interferences that may cause inaccuracies or poor CGM performance, and 4) required steps for full regulatory approval of CGMs in the hospital and future research steps to advance the field forward. (c) 2023 AACE. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:919 / 927
页数:9
相关论文
共 50 条
  • [1] Evaluating the accuracy of continuous glucose-monitoring sensors
    Kovatchev, BP
    Gonder-Frederick, LA
    Cox, DJ
    Clarke, WL
    DIABETES CARE, 2004, 27 (08) : 1922 - 1928
  • [2] Accuracy of continuous glucose monitoring in the hospital setting: an observational study
    O'Connor, Mollie Y.
    Flint, Kristen L.
    Sabean, Amy
    Ashley, Annabelle
    Zheng, Hui
    Yan, Joyce
    Steiner, Barbara A.
    Anandakugan, Nillani
    Calverley, Melissa
    Bartholomew, Rachel
    Greaux, Evelyn
    Larkin, Mary
    Russell, Steven J.
    Putman, Melissa S.
    DIABETOLOGIA, 2024, 67 (12) : 2650 - 2659
  • [3] Continuous Glucose Monitoring in the Hospital
    Perez-Guzman, M. Citlalli
    Shang, Trisha
    Zhang, Jennifer Y.
    Jornsay, Donna
    Klonoff, David C.
    ENDOCRINOLOGY AND METABOLISM, 2021, 36 (02) : 240 - 255
  • [4] Fluorescent Sensors for Continuous Glucose Monitoring
    Heo, Yun Jung
    2019 13TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE & ENGINEERING (IEEE-NANOMED 2019), 2019, : 60 - 60
  • [5] Optical sensors for continuous glucose monitoring
    Yu, Ziyi
    Jiang, Nan
    Kazarian, Sergei G.
    Tasoglu, Savas
    Yetisen, Ali K.
    PROGRESS IN BIOMEDICAL ENGINEERING, 2021, 3 (02):
  • [6] Wearable textile sensors for continuous glucose monitoring
    Sunstrum, Frederique N.
    Khan, Jawairia Umar
    Li, Nga-Wun
    Welsh, Alec W.
    BIOSENSORS & BIOELECTRONICS, 2025, 273
  • [7] OVERVIEW OF MODERN SENSORS FOR CONTINUOUS GLUCOSE MONITORING
    Momynaliev, Kuvat T.
    Prokopiev, Maxim V.
    Ivanov, Igor V.
    DIABETES MELLITUS, 2023, 26 (06): : 575 - 584
  • [8] Accuracy of Continuous Glucose Monitoring in People With Type 1 Diabetes Receiving Hemodialysis in Hospital
    Wang, Ray
    Kyi, Mervyn
    Krishnamoorthi, Brintha
    Connell, Ailie
    Chiang, Cherie
    Renouf, Debra
    Barmanray, Rahul
    Dwyer, Karen
    Fourlanos, Spiros
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2025,
  • [9] Clinical Implications of Accuracy Measurements of Continuous Glucose Sensors
    Bailey, Timothy S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 : S51 - S54
  • [10] Hypoglycemia Reduction and Accuracy of Continuous Glucose Monitoring
    Kovatchev, Boris P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (08) : 530 - 533